DTC P0A95 High Voltage Fuse |
| DTC No. | DTC Detection Condition | Trouble Area |
| P0A95 | Voltage between VBB9 and VBB10 terminals is below standard in spite of interlock switch being engaged (1 trip detection logic) |
|

| 1.READ DTC OUTPUT (DTC P0A1F IS OUTPUT) |
Connect the Techstream to the DLC3.
Turn the power switch ON (IG) and the tester ON.
Enter the following menus: Powertrain / HV Battery / DTC.
Read DTCs.
|
| ||||
| NO | |
| 2.INSPECT SERVICE PLUG GRIP |
Turn the power switch OFF.
![]() |
Remove the service plug grip (Click here).
Measure the resistance of the service plug grip.
|
| ||||
| OK | |
| 3.INSPECT BATTERY PLUG |
Remove the HV battery assembly (Click here).
Remove the battery plug (Click here).
![]() |
Measure the resistance of the battery plug.
| Tester Connection | Specified Condition |
| A - C | Below 1 Ω |
| B - D | Below 1 Ω |
Reinstall the battery plug (Click here).
Reinstall the HV battery assembly (Click here).
|
| ||||
| OK | ||
| ||
| 4.INSPECT HIGH VOLTAGE FUSE |
![]() |
Remove the high voltage fuse (Click here).
Measure the resistance of the high voltage fuse.
Reinstall the high voltage fuse.
|
| ||||
| OK | ||
| ||