DTC C1315/31 SMC1 Changeover Solenoid Malfunction |
DTC C1316/32 SMC2 Changeover Solenoid Malfunction |
DTC C1352/21 Front Increasing Pressure Solenoid RH Malfunction |
DTC C1353/23 Front Increasing Pressure Solenoid LH Malfunction |
DTC C1354/25 Rear Increasing Pressure Solenoid RH Malfunction |
DTC C1355/27 Rear Increasing Pressure Solenoid LH Malfunction |
DTC C1356/22 Front Decreasing Pressure Solenoid RH Malfunction |
DTC C1357/24 Front Decreasing Pressure Solenoid LH Malfunction |
DTC C1358/26 Rear Decreasing Pressure Solenoid RH Malfunction |
DTC C1359/28 Rear Decreasing Pressure Solenoid LH Malfunction |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| C1315/31 | 61 | When either condition below is met:
|
|
| C1315/31 | 62 | Open circuit in SMC1 continues for 0.05 sec. or more when SMC1 is off |
|
| C1315/31 | 63 | Open circuit in SMC1 continues for 0.05 sec. or more when SMC1 is off. |
|
| C1315/31 | 64 | Over current in SMC1 continues for 0.05 sec. or more. |
|
| C1316/32 | 66 | When either condition below is met:
|
|
| C1316/32 | 67 | Open circuit in SMC2 continues for 0.05 sec. or more when SMC2 is off. |
|
| C1316/32 | 68 | Open circuit in SMC2 continues for 0.05 sec. or more. |
|
| C1316/32 | 69 | Over current in SMC2 continues for 0.05 sec. or more. |
|
| C1352/21 | 11 | Open circuit in SLAFR continues for 0.05 sec. or more when SLAFR is off. |
|
| C1352/21 | 12 | Open circuit in SLAFR continues for 0.05 sec. or more when SLAFR is on. |
|
| C1352/21 | 13 | Short to +B or voltage leak in SLAFR continues for 0.05 sec. or more. |
|
| C1352/21 | 14 | Over current in SLAFR continues for 0.05 sec. or more. |
|
| C1353/23 | 21 | Open circuit in SLAFL continues for 0.05 sec. or more when SLAFL is off. |
|
| C1353/23 | 22 | Open circuit in SLAFL continues for 0.05 sec. or more when SLAFL is on. |
|
| C1353/23 | 23 | Short to +B or voltage leak in SLAFL continues for 0.05 sec. or more. |
|
| C1353/23 | 24 | Over current in SLAFL continues for 0.05 sec. or more. |
|
| C1354/25 | 31 | Open circuit in SLARR continues for 0.05 sec. or more when SLARR is off. |
|
| C1354/25 | 32 | Open circuit in SLARR continues for 0.05 sec. or more when SLARR is on. |
|
| C1354/25 | 33 | Short to +B or voltage leak in SLARR continues for 0.05 sec. or more. |
|
| C1354/25 | 34 | Over current in SLARR continues for 0.05 sec. or more. |
|
| C1355/27 | 41 | Open circuit in SLARL continues for 0.05 sec. or more when SLARL is off. |
|
| C1355/27 | 42 | Open circuit in SLARL continues for 0.05 sec. or more when SLARL is on. |
|
| C1355/27 | 43 | Short to +B or voltage leak in SLARL continues for 0.05 sec. or more. |
|
| C1355/27 | 44 | Over current in SLARL continues for 0.05 sec. or more. |
|
| C1356/22 | 16 | Open circuit in SLRFR continues for 0.05 sec. or more when SLRFR is off. |
|
| C1356/22 | 17 | Open circuit in SLRFR continues for 0.05 sec. or more when SKRFR is on. |
|
| C1356/22 | 18 | Short to +B or voltage leak in SLRFR continues for 0.05 sec. or more. |
|
| C1356/22 | 19 | Over current in SLRFR continues for 0.05 sec. or more. |
|
| C1357/24 | 26 | Open circuit in SLRFL continues or 0.05 sec. or more when SLRFL is off. |
|
| C1357/24 | 27 | Open circuit in SLRFL continues for 0.05 sec. or more when SLRFL is on. |
|
| C1357/24 | 28 | Short to +B or voltage leak in SLRFL continues for 0.05 sec. or more. |
|
| C1357/24 | 29 | Over current in SLRFL continues for 0.05 sec. or more. |
|
| C1358/26 | 36 | Open circuit in SLRRR continues for 0.05 sec. or more when SLRRR is off. |
|
| C1358/26 | 37 | Open circuit in SLRRR continues for 0.05 sec. or more when SLRRR is on. |
|
| C1358/26 | 38 | Short to +B or voltage leak in SLRRR continues for 0.05 sec. or more. |
|
| C1358/26 | 39 | Over current in SLRRR continues for 0.05 sec. or more. |
|
| C1359/28 | 46 | Open circuit in SLRRL continues for 0.05 sec. or more when SLRRL is off. |
|
| C1359/28 | 47 | Open circuit in SLRRL continues for 0.05 sec. or more when SLRRL is on. |
|
| C1359/28 | 48 | Short to +B or voltage leak in SLRRL continues for 0.05 sec. or more. |
|
| C1359/28 | 49 | Over current in SLRRL continues for 0.05 sec. or more. |
|


| 1.INSPECT BRAKE ACTUATOR ASSEMBLY |
![]() |
Disconnect the brake actuator connector.
Measure the resistance of the actuator.
| Tester Connection | Specified Condition |
| A2-20 (SMC1) - A2-19 (BS1) | 14.6 to 24.6 Ω |
| A2-6 (SMC2) - A2-7 (BS2) | 14.6 to 24.6 Ω |
| A2-8 (FR+) - A2-5 (FR-) | 3.5 to 4.3 Ω |
| A2-22 (FR+) - A2-21 (FR-) | 3.5 to 4.3 Ω |
| A2-13 (FL+) - A2-14 (FL-) | 3.5 to 4.3 Ω |
| A2-27 (FL+) - A2-28 (FL-) | 3.5 to 4.3 Ω |
| A2-12 (RR+) - A2-11 (RR-) | 3.5 to 4.3 Ω |
| A2-10 (RL+) - A2-9 (RL-) | 3.5 to 4.3 Ω |
|
| ||||
| OK | |
| 2.CHECK SKID CONTROL ECU (VALVE VOLTAGE) |

Measure the voltage of the ECU connector.
| Tester Connection | Condition | Specified Condition |
| S7-4 (SMC1) - Body ground | Power switch ON (READY) Brake pedal released | 10 to 14 V |
| S10-3 (SMC2) - Body ground | Power switch ON (READY) Brake pedal released | 10 to 14 V |
| S7-7 (SLAFR+) - Body ground | Power switch ON (READY) Brake pedal released | Pulse generation* |
| S7-6 (SLAFR-) - Body ground | Power switch ON (READY) Brake pedal released | Pulse generation* |
| S10-1 (SLAFL+) - Body ground | Power switch ON (READY) Brake pedal released | Pulse generation* |
| S10-2 (SLAFL-) - Body ground | Power switch ON (READY) Brake pedal released | Pulse generation* |
| S10-19 (SLARR+) - Body ground | Power switch ON (READY) Brake pedal released | Pulse generation* |
| S10-9 (SLARR-) - Body ground | Power switch ON (READY) Brake pedal released | Pulse generation* |
| S7-15 (SLARL+) - Body ground | Power switch ON (READY) Brake pedal released | Pulse generation* |
| S7-27 (SLARL-) - Body ground | Power switch ON (READY) Brake pedal released | Pulse generation* |
| S7-17 (SLRFR+) - Body ground | Power switch ON (READY) Brake pedal released | Below 1.5 V |
| S10-8 (SLRFL+) - Body ground | Power switch ON (READY) Brake pedal released | Below 1.5 V |
| S10-20 (SLRRR+) - Body ground | Power switch ON (READY) Brake pedal released | Below 1.5 V |
| S7-16 (SLRRL+) - Body ground | Power switch ON (READY) Brake pedal released | Below 1.5 V |
| S7-34 (SLRFR-) - Body ground | Power switch ON (READY) | Below 1.5 V |
| S10-26 (SLRFL-) - Body ground | Power switch ON (READY) Brake pedal released | Below 1.5 V |
| S10-18 (SLRRR-) - Body ground | Power switch ON (READY) Brake pedal released | Below 1.5 V |
| S7-26 (SLRRL-) - Body ground | Power switch ON (READY) Brake pedal released | Below 1.5 V |
|
| ||||
| OK | ||
| ||