GENERATOR CABLE > INSTALLATION |
| 1. INSTALL GENERATOR CABLE |
![]() |
Apply a small amount of ATF WS to the generator cable's O-ring.
![]() |
Connect the generator cable as shown in the illustration.
![]() |
Install the generator cable (terminals) with the 3 bolts.
![]() |
Install the generator cable with the 2 bolts.
![]() |
Apply seal packing in a continuous line of beads (diameter 1.5 mm, 0.059 in.) to the power cable cover.
![]() |
Install the power cable cover with the 4 bolts.
| 2. INSTALL INVERTER WITH CONVERTER ASSEMBLY |
Install the inverter with converter (Click here).
| 3. INSTALL FRONT COWL TOP PANEL OUTER SUB-ASSEMBLY |
Install the cowl top front panel .
| 4. INSTALL ENGINE UNDER COVER RH |
| 5. INSTALL ENGINE UNDER COVER LH |
| 6. INSTALL SERVICE PLUG GRIP |
Install the service plug grip (Click here).
| 7. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL |
| 8. ADD COOLANT (for Inverter) |
Add coolant (Click here).
| 9. INSPECT FOR COOLANT LEAK (for Inverter) |
Check for engine coolant leaks .