89465
1.INSTALL HEATED OXYGEN SENSOR
Using SST, install the heated oxygen sensor onto the front exhaust pipe.
| *a | Fulcrum Length
30 mm (1.18 in.) |
| *b | Fulcrum Length
260 mm (10.2 in.) |
The "with SST" torque value is effective when using SST with a fulcrum length of 30 mm (1.18 in.) and a torque wrench with a fulcrum length of 260 mm (10.2 in.) (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).
The "with SST" torque value is effective when SST is parallel to the torque wrench.
17141
2.INSTALL EXHAUST MANIFOLD