The power management control ECU monitors its internal operation, it will set DTCs and perform fail-safe control when it detects the following malfunctions.
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| P3004 | 133 | A high-voltage wiring system error signal is detected in the power management control ECU | ·
Power management control ECU ·
HV battery junction block assembly ·
Battery smart unit ·
Wire harness or connector |
Before inspecting the high-voltage system, take safety precautions to prevent electrical shocks, such as wearing insulated gloves and removing the service plug grip. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION
At least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Drive the vehicle for approximately 10 minutes according to the freeze frame data items "Vehicle Spd", "Accelerator Degree" and "Power Resource IB".
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Check if DTCs are output.
| Result | Proceed to |
|---|---|
| P3004-133 only is output. | A |
| DTCs other than P3004-133 is output. | B |
Turn the power switch off.
A
B
(See pageEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART)
Connect the intelligent tester to the DLC3.
Turn the power switch to on (IG).
Enter the following menus: Powertrain / Hybrid Control / Data List / Power Resource IB.
Read the Data List.
| Result | Proceed to |
|---|---|
| The value of Power Resource IB is between -4 A and 4 A | A |
| Other than above | B |
Turn the power switch off.
A
B
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 1 hybrid battery shield sub-assembly.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY SMART UNIT>REMOVAL
Remove the No. 2 hybrid battery shield sub-assembly.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV RELAY ASSEMBLY>REMOVAL
Disconnect only the d1 connector of the battery smart unit.
Disconnect the d2 battery current sensor connector from the HV battery junction block assembly.
Measure the resistance according to the value(s) in the tables below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| d1-5 (IB) - d2-3 (IB) | Power switch off | Below 1 Ω |
| d1-12 (GIB) - d2-2 (GIB) | Power switch off | Below 1 Ω |
| d1-6 (VIB) - d2-1 (VIB) | Power switch off | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| d1-5 (IB) or d2-3 (IB) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| d1-12 (GIB) or d2-2 (GIB) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| d1-6 (VIB) or d2-1 (VIB) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| *a | Rear view of wire harness connector
(to Battery Smart Unit) |
| *b | Front view of wire harness connector
(to HV Battery Junction Block Assembly) |
Because the battery harness is not available as a supply part, if the harness cannot be repaired, replace the HV battery assembly.
Connect the battery smart unit connector.
Connect the battery current sensor connector to the HV battery junction block assembly.
Install the No. 2 hybrid battery shield sub-assembly.
Install the No. 1 hybrid battery shield sub-assembly.
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch to on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 1 hybrid battery shield sub-assembly.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY SMART UNIT>REMOVAL
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch to on (IG).
| *a | Component with harness connected
(Battery Smart Unit) |
Using a toyota electrical tester set to 40 V, measure the VIB voltage according to the value(s) in the table below.
| Tester Connection | Condition |
|---|---|
| d1-6(VIB) - d1-12(GIB) | Power switch on (IG) |
Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Be sure to set the toyota electrical tester to 40 V when performing this test.
| *a | Component with harness connected
(Battery Smart Unit) |
Using a toyota electrical tester set to 4 V, measure the IB voltage according to the value(s) in the table below.
| Tester Connection | Condition |
|---|---|
| d1-5(IB) - d1-12(GIB) | Power switch on (IG) |
Be sure to set the toyota electrical tester to 4 V when performing this test.
Compare the measured values of the IB terminal voltage and VIB terminal voltage using the following formula:
| IB voltage - VIB Voltage / 2 = less than 0.081 V |
| IB voltage - VIB Voltage / 2 = -0.081 V or higher |
| Result | Proceed to |
|---|---|
| Within the specified range above | A |
| Other than above | B |
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Install the No. 1 hybrid battery shield sub-assembly.
When the power switch is on (IG) the actual current will be approximately 0 A. The following graph shows the relation of the actual output voltage of the battery current sensor terminal IB and actual current used for DTC judgment.
A
B
NEXT
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Clear the DTCs and freeze frame data.
Drive the vehicle on urban roads for approximately 10 minutes.
Turn the power switch off and wait for 2 minutes or more.
Turn the power switch on (IG) and wait for 30 seconds or more.
NEXT
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Read output DTCs.
Turn the power switch off.
| Result | Proceed to |
|---|---|
| DTCs are not output | A |
| P3004-133 is output | B |
A
B