Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID BATTERY SYSTEM › 2014.12–2015.11
RM2170E _51 Engine / Hybrid System _057004 HYBRID / BATTERY CONTROL _0277925 HYBRID BATTERY SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID BATTERY SYSTEM  P0A7F-123  Hybrid Battery Pack Deterioration  


DESCRIPTION

The battery smart unit and the hybrid vehicle control ECU calculate the SOC (state of charge) of the HV battery through the accumulated amperage in the HV battery. The battery smart unit sends the condition of the HV battery to the hybrid vehicle control ECU. Then the hybrid vehicle control ECU calculates the SOC based on the information and controls HV battery charge and discharge according to the driving condition.

A379359E02
2.823,1.302 2.615,0.792 2.615,0.792 2.323,0.792 false 3.521,1.208 3.521,0.396 3.521,0.396 3.76,0.396 false 3.906,1.354 4.406,0.75 4.406,0.75 4.74,0.75 false 4.51,1.969 4.229,1.969 4.229,1.969 3.813,1.396 false 3.51,2.167 3.51,1.583 false 1.333,0.698 2.302,1.01 0.969,0.313 10 false Control Region 3.854,0.313 5.854,0.719 2,0.406 10 false Upper SOC Control Limit 4.792,0.667 6.927,1 2.135,0.333 10 false Example of Change in SOC 4.573,1.885 6.906,2.354 2.333,0.469 10 false Central SOC Level 2.833,2.229 4.552,2.521 1.719,0.292 10 false Lower SOC Control Limit 2.833,1.917 3.51,2.219 0.677,0.302 10 false Time 2.052,1.208 2.729,1.51 0.677,0.302 10 false SOC

DTC No. INF Code DTC Detection Condition Trouble Area
P0A7F 123
·

Internal resistance of the HV battery is higher than the standard (1 trip detection)

·

Difference in the capacity between battery blocks is larger than the standard (2 trip detection)


·

HV battery

·

Battery smart unit



HINT:
·

P0A7F-123 will not be set unless the vehicle is driven for approximately 10 minutes after clearing the DTC. (As 2 trip detection logic is used, check for DTCs including pending DTCs.)

·

In order to ensure HV battery performance, appropriate cooling performance must be maintained. Perform the following items as necessary. If cooling performance has decreased and "COOLING PERFORMANCE OF THE HYBRID BATTERY IS LOW VISIT YOUR DEALER" is displayed on the multi-information display, make sure to perform the following items:

-

Make sure the air intake port is not blocked.

-

Clean the battery cooling blower filter.

Clear the DTCs to reset the learning values even if no DTCs are stored.






CAUTION / NOTICE / HINT

CAUTION:

When disposing of an HV battery, make sure to return it through an authorized collection agent who is capable of handling it safely. If the HV battery is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.


PROCEDURE

1.CHECK DTC OUTPUT (HYBRID CONTROL)
a.

Connect the intelligent tester to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / DTC.


d.

Read output DTCs (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>DTC CHECK / CLEAR).

Result:
Result Proceed to
P0AFC-123 is not output. A
P0AFC-123 is also output. B



e.

Turn the power switch off.


f.

Disconnect the intelligent tester from the DLC3.



A

2.READ VALUE USING INTELLIGENT TESTER (VB1 - VB10)

B

2.READ VALUE USING INTELLIGENT TESTER (VB1 - VB10)
a.

Ensure the safety of the areas in front and at the back of the vehicle.


b.

Apply the parking brake and secure the wheels using chocks.


c.

Connect the intelligent tester to the DLC3.


d.

Turn the power switch on (READY).


e.

Fully warm up the engine and turn the air conditioning off.


f.

Enter the following menus: Powertrain / Hybrid Control / Data List / Battery block Vol -V01 to V10.


g.

Firmly depress the brake pedal with your left foot.


h.

Move the shift lever to D.


i.

Record each battery block voltage from the Data List "Battery block Vol -V01 to V10" while fully depressing the accelerator pedal.


j.

Compare the battery block voltages "Battery block Vol -V01 to V10" between the even and odd number groups in each combination shown in the table below.


Table 1
Circuit A Battery Block Circuit B Battery Block Condition
Battery Block Vol -V01 (VB1) Battery Block Vol -V02 (VB2) "Battery Block Vol -V01" - "Battery Block Vol -V02" = 0.3 V or more
Battery Block Vol -V04 (VB4) Battery Block Vol -V03 (VB3) "Battery Block Vol -V04" - "Battery Block Vol -V03" = 0.3 V or more
Battery Block Vol -V05 (VB5) Battery Block Vol -V06 (VB6) "Battery Block Vol -V05" - "Battery Block Vol -V06" = 0.3 V or more
Battery Block Vol -V08 (VB8) Battery Block Vol -V07 (VB7) "Battery Block Vol -V08" - "Battery Block Vol -V07" = 0.3 V or more
Battery Block Vol -V09 (VB9) Battery Block Vol -V10 (VB10) "Battery Block Vol -V09" - "Battery Block Vol -V10" = 0.3 V or more

Table 2
Circuit A Battery Block Circuit B Battery Block Condition
Battery Block Vol -V01 (VB1) Battery Block Vol -V02 (VB2) "Battery Block Vol -V02" - "Battery Block Vol -V01" = 0.3 V or more
Battery Block Vol -V04 (VB4) Battery Block Vol -V03 (VB3) "Battery Block Vol -V03" - "Battery Block Vol -V04" = 0.3 V or more
Battery Block Vol -V05 (VB5) Battery Block Vol -V06 (VB6) "Battery Block Vol -V06" - "Battery Block Vol -V05" = 0.3 V or more
Battery Block Vol -V08 (VB8) Battery Block Vol -V07 (VB7) "Battery Block Vol -V07" - "Battery Block Vol -V08" = 0.3 V or more
Battery Block Vol -V09 (VB9) Battery Block Vol -V10 (VB10) "Battery Block Vol -V10" - "Battery Block Vol -V09" = 0.3 V or more

A298791E05
1.271,1.667 1.542,1.063 false 2.26,1.667 2.531,1.063 false 3.271,1.667 3.542,1.063 false 4.281,1.667 4.552,1.063 false 5.271,1.677 5.542,1.073 false 1.271,4.26 1.542,3.656 false 2.26,4.25 2.531,3.646 false 3.26,4.25 3.531,3.646 false 4.271,4.25 4.542,3.646 false 5.25,4.26 5.521,3.656 false 0.125,0.104 5.031,0.375 4.906,0.271 10 false Example: When the difference in voltage of all 5 pairs of blocks is 0.3 V or more 0.219,0.417 2.375,0.688 2.156,0.271 10 false All Conditions in table 1 are met. 4.958,0.26 7.115,0.531 2.156,0.271 10 false A: Circuit A Battery Block Voltage 4.969,0.521 7.125,0.792 2.156,0.271 10 false B: Circuit B Battery Block Voltage 1.573,0.99 2.573,1.26 1,0.271 10 false 0.3 V or more 2.573,0.979 3.573,1.25 1,0.271 10 false 0.3 V or more 3.583,0.979 4.583,1.25 1,0.271 10 false 0.3 V or more 4.594,0.979 5.594,1.25 1,0.271 10 false 0.3 V or more 5.583,0.99 6.583,1.26 1,0.271 10 false 0.3 V or more 0.385,1.427 0.708,1.708 0.323,0.281 10 false V 0.719,2.74 1.042,3.021 0.323,0.281 10 false VB1 1.052,2.74 1.375,3.021 0.323,0.281 10 false VB2 0.844,2.885 1.167,3.167 0.323,0.281 10 false A 1.094,2.875 1.417,3.156 0.323,0.281 10 false B 1.74,2.74 2.063,3.021 0.323,0.281 10 false VB3 2.052,2.75 2.375,3.031 0.323,0.281 10 false VB4 2.74,2.75 3.063,3.031 0.323,0.281 10 false VB5 3.063,2.75 3.385,3.031 0.323,0.281 10 false VB6 3.75,2.74 4.073,3.021 0.323,0.281 10 false VB7 4.073,2.74 4.396,3.021 0.323,0.281 10 false VB8 4.74,2.74 5.063,3.021 0.323,0.281 10 false VB9 5.083,2.74 5.667,3.083 0.583,0.344 10 false VB10 1.844,2.885 2.167,3.167 0.323,0.281 10 false B 2.115,2.885 2.438,3.167 0.323,0.281 10 false A 2.844,2.896 3.167,3.177 0.323,0.281 10 false A 4.167,2.906 4.49,3.188 0.323,0.281 10 false A 4.854,2.906 5.177,3.188 0.323,0.281 10 false A 3.115,2.896 3.438,3.177 0.323,0.281 10 false B 3.833,2.906 4.156,3.188 0.323,0.281 10 false B 5.177,2.906 5.5,3.188 0.323,0.281 10 false B 0.677,5.333 1.146,5.646 0.469,0.313 10 false VB1 5.552,3.563 6.552,3.833 1,0.271 10 false 0.3 V or more 4.594,3.552 5.594,3.823 1,0.271 10 false 0.3 V or more 3.583,3.542 4.583,3.813 1,0.271 10 false 0.3 V or more 2.563,3.542 3.563,3.813 1,0.271 10 false 0.3 V or more 1.573,3.542 2.573,3.813 1,0.271 10 false 0.3 V or more 0.406,4.125 0.729,4.406 0.323,0.281 10 false V 1.052,5.333 1.51,5.604 0.458,0.271 10 false VB2 1.677,5.333 2.177,5.625 0.5,0.292 10 false VB3 2.052,5.333 2.542,5.615 0.49,0.281 10 false VB4 2.667,5.333 3.094,5.594 0.427,0.26 10 false VB5 3.052,5.333 3.542,5.625 0.49,0.292 10 false VB6 3.688,5.344 4.156,5.656 0.469,0.313 10 false VB7 4.052,5.344 4.458,5.656 0.406,0.313 10 false VB8 4.719,5.344 5.188,5.635 0.469,0.292 10 false VB9 5.042,5.344 5.688,5.677 0.646,0.333 10 false VB10 5.104,5.5 5.427,5.781 0.323,0.281 10 false B 1.833,5.49 2.156,5.771 0.323,0.281 10 false B 3.844,5.5 4.167,5.781 0.323,0.281 10 false B 2.865,5.49 3.188,5.771 0.323,0.281 10 false A 0.854,5.5 1.177,5.781 0.323,0.281 10 false A 4.833,5.51 5.156,5.792 0.323,0.281 10 false A 4.115,5.5 4.438,5.781 0.323,0.281 10 false A 3.083,5.49 3.406,5.771 0.323,0.281 10 false B 2.083,5.49 2.406,5.771 0.323,0.281 10 false A 1.135,5.5 1.458,5.781 0.323,0.281 10 false B 0.135,3.188 2.292,3.458 2.156,0.271 10 false All Conditions in table 2 are met.

HINT:

When an internal malfunction occurs in the battery smart unit, this symptom (difference in voltage of 0.3 V or more for all 5 pairs of blocks) will occur.


Result:
Result Proceed to
All conditions in table 1 are met. A
All conditions in table 2 are met.
Other than above B


k.

Turn the power switch off.



A

B