The battery smart unit and the hybrid vehicle control ECU calculate the SOC (state of charge) of the HV battery through the accumulated amperage in the HV battery. The battery smart unit sends the condition of the HV battery to the hybrid vehicle control ECU. Then the hybrid vehicle control ECU calculates the SOC based on the information and controls HV battery charge and discharge according to the driving condition.
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| P0A7F | 123 | ·
Internal resistance of the HV battery is higher than the standard (1 trip detection) ·
Difference in the capacity between battery blocks is larger than the standard (2 trip detection) |
·
HV battery ·
Battery smart unit |
P0A7F-123 will not be set unless the vehicle is driven for approximately 10 minutes after clearing the DTC. (As 2 trip detection logic is used, check for DTCs including pending DTCs.)
In order to ensure HV battery performance, appropriate cooling performance must be maintained. Perform the following items as necessary. If cooling performance has decreased and "COOLING PERFORMANCE OF THE HYBRID BATTERY IS LOW VISIT YOUR DEALER" is displayed on the multi-information display, make sure to perform the following items:
Make sure the air intake port is not blocked.
Clean the battery cooling blower filter.
Clear the DTCs to reset the learning values even if no DTCs are stored.
When disposing of an HV battery, make sure to return it through an authorized collection agent who is capable of handling it safely. If the HV battery is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Read output DTCs (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>DTC CHECK / CLEAR).
| Result | Proceed to |
|---|---|
| P0AFC-123 is not output. | A |
| P0AFC-123 is also output. | B |
Turn the power switch off.
Disconnect the intelligent tester from the DLC3.
A
B
Ensure the safety of the areas in front and at the back of the vehicle.
Apply the parking brake and secure the wheels using chocks.
Connect the intelligent tester to the DLC3.
Turn the power switch on (READY).
Fully warm up the engine and turn the air conditioning off.
Enter the following menus: Powertrain / Hybrid Control / Data List / Battery block Vol -V01 to V10.
Firmly depress the brake pedal with your left foot.
Move the shift lever to D.
Record each battery block voltage from the Data List "Battery block Vol -V01 to V10" while fully depressing the accelerator pedal.
Compare the battery block voltages "Battery block Vol -V01 to V10" between the even and odd number groups in each combination shown in the table below.
| Circuit A Battery Block | Circuit B Battery Block | Condition |
|---|---|---|
| Battery Block Vol -V01 (VB1) | Battery Block Vol -V02 (VB2) | "Battery Block Vol -V01" - "Battery Block Vol -V02" = 0.3 V or more |
| Battery Block Vol -V04 (VB4) | Battery Block Vol -V03 (VB3) | "Battery Block Vol -V04" - "Battery Block Vol -V03" = 0.3 V or more |
| Battery Block Vol -V05 (VB5) | Battery Block Vol -V06 (VB6) | "Battery Block Vol -V05" - "Battery Block Vol -V06" = 0.3 V or more |
| Battery Block Vol -V08 (VB8) | Battery Block Vol -V07 (VB7) | "Battery Block Vol -V08" - "Battery Block Vol -V07" = 0.3 V or more |
| Battery Block Vol -V09 (VB9) | Battery Block Vol -V10 (VB10) | "Battery Block Vol -V09" - "Battery Block Vol -V10" = 0.3 V or more |
| Circuit A Battery Block | Circuit B Battery Block | Condition |
|---|---|---|
| Battery Block Vol -V01 (VB1) | Battery Block Vol -V02 (VB2) | "Battery Block Vol -V02" - "Battery Block Vol -V01" = 0.3 V or more |
| Battery Block Vol -V04 (VB4) | Battery Block Vol -V03 (VB3) | "Battery Block Vol -V03" - "Battery Block Vol -V04" = 0.3 V or more |
| Battery Block Vol -V05 (VB5) | Battery Block Vol -V06 (VB6) | "Battery Block Vol -V06" - "Battery Block Vol -V05" = 0.3 V or more |
| Battery Block Vol -V08 (VB8) | Battery Block Vol -V07 (VB7) | "Battery Block Vol -V07" - "Battery Block Vol -V08" = 0.3 V or more |
| Battery Block Vol -V09 (VB9) | Battery Block Vol -V10 (VB10) | "Battery Block Vol -V10" - "Battery Block Vol -V09" = 0.3 V or more |
When an internal malfunction occurs in the battery smart unit, this symptom (difference in voltage of 0.3 V or more for all 5 pairs of blocks) will occur.
| Result | Proceed to |
|---|---|
| All conditions in table 1 are met. | A |
| All conditions in table 2 are met. | |
| Other than above | B |
Turn the power switch off.
A