Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID BATTERY SYSTEM › from 2015.11
RM2170E _51 Engine / Hybrid System _057004 HYBRID / BATTERY CONTROL _0277925 HYBRID BATTERY SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID BATTERY SYSTEM  P0A95-123  High Voltage Fuse  


DESCRIPTION

DTC No. INF Code DTC Detection Condition Trouble Area
P0A95 123 Voltage between VB8 and VB9 terminals is below the standard despite the interlock switch being engaged (1 trip detection)
·

Service plug grip

·

HV battery



WIRING DIAGRAM

A262491E18
1.281,1.656 0.948,1.844 0.948,1.844 0.948,1.948 false 0.583,1.979 1.417,2.625 0.833,0.646 10 false Service Plug Grip 5.021,0.75 5.427,1.063 0.406,0.313 10 false VB5 5.021,1.75 5.427,2.063 0.406,0.313 10 false VB4 4.75,0.646 5.021,0.875 0.271,0.229 10 false 8 4.688,1.615 4.958,1.844 0.271,0.229 10 false 18 4.677,2.281 4.885,2.521 0.208,0.24 10 false z9 4.896,2.281 6.115,2.594 1.219,0.313 10 false Battery Smart Unit 2.375,2.344 3.073,2.698 0.698,0.354 10 false HV Battery 1.458,0.083 1.625,0.25 0.167,0.167 10 false + 1.469,2.333 1.635,2.5 0.167,0.167 10 false -

CAUTION / NOTICE / HINT

CAUTION:
·

Before inspecting the high-voltage system, take safety precautions to prevent electrical shocks, such as wearing insulated gloves and removing the service plug grip. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·

After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>PRECAUTION).

HINT:

At least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.


·

When disposing of an HV battery, make sure to return it through an authorized collection agent who is capable of handling it safely. If the HV battery is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.



NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).


PROCEDURE

1.CHECK DTC OUTPUT (HYBRID CONTROL)

A

2.CHECK SERVICE PLUG GRIP

B

2.CHECK SERVICE PLUG GRIP
a.

Turn the power switch off.


b.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



c.
U110459

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Standard Resistance
Service plug grip Below 1 Ω




OK

NG

3.REPLACE SERVICE PLUG GRIP
3.REPLACE SERVICE PLUG GRIP

NEXT

4.RECONFIRM DTC OUTPUT (HYBRID CONTROL)
4.RECONFIRM DTC OUTPUT (HYBRID CONTROL)
a.

Connect the intelligent tester to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / DTC.


d.

Read output DTCs (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>DTC CHECK / CLEAR).

Result:
Result Proceed to
DTCs are not output. A
DTCs are also output. B



e.

Disconnect the intelligent tester from the DLC3.



A

RECOVERY TO NORMAL

B