The battery temperature sensors are provided at 3 locations of the HV battery. The resistance of the thermistor, which is built into each battery temperature sensor, varies in accordance with changes in the HV battery temperature. The lower the battery temperature, the higher the thermistor resistance. Conversely, the higher the temperature, the lower the resistance. The battery smart unit uses the battery temperature sensors to detect the HV battery temperature, and sends the detected value to the power management control ECU. Based on the results of this detection, the power management control ECU controls the blower fan. (The blower fan starts when HV battery temperature rises above a predetermined level.)
| DTC Title Sensor | Battery Temperature Sensor | Intelligent tester Display |
|---|---|---|
| A | 0 | 1 |
| B | 1 | 2 |
| C | 2 | 3 |
For example, sensor A in the DTC title is battery temperature sensor (No. 0). This sensor is displayed as Temp of Batt TB1 in the Data List.
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| P0A9C
P0AC6 P0ACB P3065 |
123 | When the battery temperature sensor performance is abnormal (1 trip detection/2 trip detection) | ·
Hybrid battery thermistor ·
Battery smart unit ·
Wire harness or connector |
Before inspecting the high-voltage system, take safety precautions to prevent electrical shocks, such as wearing insulated gloves and removing the service plug grip. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>PRECAUTION).
At least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
When disposing of an HV battery, make sure to return it through an authorized collection agent who is capable of handling it safely. If the HV battery is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).
A
B
Be sure to wear insulated gloves and protective goggles.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the upper hybrid battery cover sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>REMOVAL).
Visually check the installation condition of the relevant battery temperature sensor.
| *A | for 2 Clamps Type | *B | for 6 Clamps Type |
| *1 | Battery Temperature Sensor 0 | *2 | Battery Temperature Sensor 1 |
| *3 | Battery Temperature Sensor 2 | - | - |
Each battery temperature sensor is installed in the correct location with the correct orientation and its claws are engaged securely.
| Result | Proceed to |
|---|---|
| Each battery temperature sensor is installed in the correct location with the correct orientation and its claws are engaged securely | A |
| Claws are damaged. | B |
| Any of battery temperature sensors are not installed correctly, but claws are not damaged. | C |
Do not use a stick or similar object to push on the sensors when inspecting them. Doing so may result in damage to the sensors.
Install the upper hybrid battery cover sub-assembly.
A
B
C
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 1 hybrid battery shield sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY SMART UNIT>REMOVAL).
Disconnect connectors d1 and M39 from the battery smart unit.
Measure the resistance of the circuit for the malfunctioning sensor (battery temperature sensor 0 to 2).
| Tester Connection | Battery Temperature Sensor No. |
|---|---|
| d1-4 (TBO) - d1-10 (GBO) | 0 |
| d1-3 (TB1) - d1-9 (GB1) | 1 |
| d1-2 (TB2) - d1-8 (GB2) | 2 |
| Thermistor Temperature | Switch Condition | Specified Condition |
|---|---|---|
| 0°C (32°F) | Power switch off | 26.7 to 27.8 kΩ |
| 25°C (77°F) | Power switch off | 9.9 to 10.1 kΩ |
| 40°C (104°F) | Power switch off | 5.73 to 5.92 kΩ |
| *a | Rear view of wire harness connector
(to Battery Smart Unit) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Standard Resistance |
|---|---|---|
| d1-4 (TBO) - M39-3 (IGCT) | Power switch off | 10 kΩ or more |
| d1-4 (TBO) - M39-6 (GND) | Power switch off | 10 kΩ or more |
| d1-10 (GBO) - M39-3 (IGCT) | Power switch off | 10 kΩ or more |
| d1-10 (GBO) - M39-6 (GND) | Power switch off | 10 kΩ or more |
| d1-3 (TB1) - M39-3 (IGCT) | Power switch off | 10 kΩ or more |
| d1-3 (TB1) - M39-6 (GND) | Power switch off | 10 kΩ or more |
| d1-9 (GB1) - M39-3 (IGCT) | Power switch off | 10 kΩ or more |
| d1-9 (GB1) - M39-6 (GND) | Power switch off | 10 kΩ or more |
| d1-2 (TB2) - M39-3 (IGCT) | Power switch off | 10 kΩ or more |
| d1-2 (TB2) - M39-6 (GND) | Power switch off | 10 kΩ or more |
| d1-8 (GB2) - M39-3 (IGCT) | Power switch off | 10 kΩ or more |
| d1-8 (GB2) - M39-6 (GND) | Power switch off | 10 kΩ or more |
| d1-1 (TCO) - M39-3 (IGCT) | Power switch off | 10 kΩ or more |
| d1-1 (TCO) - M39-6 (GND) | Power switch off | 10 kΩ or more |
| d1-7 (GCO) - M39-3 (IGCT) | Power switch off | 10 kΩ or more |
| d1-7 (GCO) - M39-6 (GND) | Power switch off | 10 kΩ or more |
| *a | Rear view of wire harness connector
(to Battery Smart Unit) |
Connect the battery smart unit connectors.
Install the No. 1 hybrid battery shield sub-assembly.
OK
NG
Be sure to wear insulated gloves and protective goggles.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the upper hybrid battery cover sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>REMOVAL).
Check the wire harness and connectors of the battery temperature sensor for abnormalities by sight and touch.
There are no open or short circuits in the wire harness and connectors. There are no short circuits to other wire harnesses.
Install the upper hybrid battery cover sub-assembly.
OK
NG