Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID BATTERY SYSTEM › 2011.12–2014.12
RM2170E _51 Engine / Hybrid System _057004 HYBRID / BATTERY CONTROL _0277925 HYBRID BATTERY SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID BATTERY SYSTEM  P0AC0-123  Hybrid Battery Pack Current Sensor Circuit Range / Performance  


DESCRIPTION

Refer to the Description for DTC P0ABF-123 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>P0ABF-123).

DTC No. INF Code DTC Detection Condition Trouble Area
P0AC0 123 When the battery current sensor is abnormal (1 or 2 trip detection)
·

Hybrid battery junction block assembly

·

Battery smart unit



PROCEDURE

1.CHECK DTC OUTPUT (HYBRID CONTROL)
a.

Connect the intelligent tester to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / DTC.


d.

Read output DTCs (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>DTC CHECK / CLEAR).

Result:
Result Proceed to
Only DTC P0AC0-123 is output or DTC P0AC0-123 and DTCs other than those in the following table are output. A
Any of the DTCs in the following table are output at the same time. B

DTC No. Relevant Diagnosis
P0A95-123 High Voltage Fuse
P0ABF-123 Hybrid Battery Pack Current Sensor Circuit
P0AC1-123 Hybrid Battery Pack Current Sensor Circuit Low
P0AC2-123 Hybrid Battery Pack Current Sensor Circuit High
P0AFC-123 Hybrid Battery Pack Sensor Module
P0B3D-123, P0B42-123, P0B47-123, P0B4C-123, P0B51-123, P0B56-123, P0B5B-123, P0B60-123, P0B65-123, P0B6A-123, P0B6F-123 Hybrid Battery Voltage Sensor "A - K" Circuit Low



e.

Turn the power switch off.


f.

Disconnect the intelligent tester from the DLC3.



A

2.READ VALUE USING INTELLIGENT TESTER

B

2.READ VALUE USING INTELLIGENT TESTER
a.

Connect the intelligent tester to the DLC3.


b.

Turn the power switch on (IG).

NOTICE:

Do not turn the power switch on (READY).



c.

Enter the following menus: Powertrain / Hybrid Control / Data List / Battery block Vol -V01 to V10.

NOTICE:

Select "Battery block Vol -V01 to V10" only. (Do not select any other Data List items.)



d.

Check the voltage of each "Battery block Vol" of "Battery block Vol -V01 to V10" in the Data List with the power switch on (IG).

A315508E16
0.104,0.083 5.469,0.531 5.365,0.448 10 false Example: The change in voltage of "Battery block Vol -V01" is less than 0.3 V. 6.74,1.25 7.156,1.531 0.417,0.281 10 false 0.3 V 0.167,2.229 5.573,2.677 5.406,0.448 10 false Example: The change in voltage of "Battery block Vol -V02" is 0.3 V or more. 0.125,1.229 1.26,1.563 1.135,0.333 10 false Less than 0.3 V 0.885,3.281 2,3.521 1.115,0.24 10 false 0.3 V or more 0.104,4.469 5.302,4.813 5.198,0.344 10 false NOTICE: Check the voltage of each other "Battery block Vol" in the same manner. 3.792,4.198 4.917,4.479 1.125,0.281 10 false 60 seconds 6.74,3.292 7.156,3.625 0.417,0.333 10 false 0.3 V

Specified Condition:

Any "Battery block Vol" changes by 0.3 V or more, 60 seconds after the power switch is turned on (IG). (the difference between the maximum and minimum voltage is 0.3 V or more.)


Result:
Result Proceed to
The change in voltage of any "Battery block Vol" is 0.3 V or more. A
Other than above. B




A

B

REPLACE HYBRID BATTERY JUNCTION BLOCK ASSEMBLY