Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID BATTERY SYSTEM › 2011.12–2014.12
RM2170E _51 Engine / Hybrid System _057004 HYBRID / BATTERY CONTROL _0277925 HYBRID BATTERY SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID BATTERY SYSTEM  P0ABF-123  Hybrid Battery Pack Current Sensor Circuit  P0AC1-123  Hybrid Battery Pack Current Sensor Circuit Low  P0AC2-123  Hybrid Battery Pack Current Sensor Circuit High  


DESCRIPTION

The battery current sensor, which is mounted on the positive cable side of the HV battery, detects the amperage that flows into the HV battery. The battery smart unit receives a voltage, which varies between 0 and 5 V in proportion to the amperage, at its IB terminal from the battery current sensor. An output voltage of the battery current sensor below 2.5 V indicates that the HV battery is being charged, and above 2.5 V indicates that the HV battery is being discharged. The power management control ECU determines the charging and discharging amperage of the HV battery based on the signals that are input to its IB terminal from the battery smart unit, and calculates the SOC (state of charge) of the HV battery through the accumulated amperage.

A260083E23
0.167,0.083 0.75,0.417 0.583,0.333 10 false Charging Current 1.063,0.083 1.844,0.417 0.781,0.333 10 false Discharging Current 1.135,1.115 2.115,1.719 0.979,0.604 10 false Battery Current Sensor 2.031,0.615 3.208,0.792 1.177,0.177 10 false Battery Smart Unit 2.375,1.563 2.635,1.74 0.26,0.177 10 false VIB 2.375,1.927 2.635,2.104 0.26,0.177 10 false GIB 2.375,1.74 2.542,1.917 0.167,0.177 10 false IB 3.917,0.948 4.146,1.115 0.229,0.167 10 false 4.5 3.917,1.688 4.146,1.854 0.229,0.167 10 false 2.5 3.917,2.417 4.146,2.583 0.229,0.167 10 false 0.5 4.219,2.719 4.521,2.875 0.302,0.156 10 false -200 6.698,2.719 6.958,2.875 0.26,0.156 10 false 200 5.552,2.719 5.667,2.875 0.115,0.156 10 false 0 4.896,3.271 6.333,3.458 1.438,0.188 10 false HV Battery Current (A) 3.479,0.219 5.885,0.552 2.406,0.333 10 false Battery Current Sensor Output Voltage 3.948,0.563 4.333,0.802 0.385,0.24 10 false (V) 4.188,3.146 4.802,3.385 0.615,0.24 10 false Charge 6.438,3.156 7.125,3.354 0.688,0.198 10 false Discharge


DTC No. INF Code DTC Detection Condition Trouble Area
P0ABF
P0AC1
P0AC2
123 When the battery current sensor is abnormal (1 trip detection)
·

Hybrid battery junction block assembly

·

Battery smart unit

·

Wire harness or connector



WIRING DIAGRAM

A388953E01
1.885,1.063 2.198,1.26 0.313,0.198 10 false IB 1.792,1.688 2.104,1.885 0.313,0.198 10 false VIB 1.792,2.333 2.104,2.531 0.313,0.198 10 false GIB 2.135,0.969 2.448,1.167 0.313,0.198 10 false 3 2.135,1.604 2.448,1.802 0.313,0.198 10 false 1 2.146,2.229 2.458,2.427 0.313,0.198 10 false 2 4.927,0.969 5.24,1.167 0.313,0.198 10 false 5 4.938,1.615 5.25,1.813 0.313,0.198 10 false 6 4.885,2.219 5.198,2.417 0.313,0.198 10 false 12 5.156,1.063 5.469,1.26 0.313,0.198 10 false IB 5.146,1.688 5.458,1.885 0.313,0.198 10 false VIB 5.135,2.333 5.448,2.531 0.313,0.198 10 false GIB 0.542,2.896 0.854,3.094 0.313,0.198 10 false d2 0.771,2.896 2.833,3.333 2.063,0.438 10 false Battery Current Sensor (Hybrid Battery Junction Block Assembly) 4.896,2.896 5.208,3.094 0.313,0.198 10 false d1 5.167,2.896 6.573,3.188 1.406,0.292 10 false Battery Smart Unit

Refer to the wiring diagram for DTC U029A-123 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>U029A-123).

CAUTION / NOTICE / HINT

CAUTION:
·

Before inspecting the high-voltage system, take safety precautions to prevent electrical shocks, such as wearing insulated gloves and removing the service plug grip. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·

After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>PRECAUTION).

HINT:

At least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.




NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).


PROCEDURE

1.CHECK DTC OUTPUT (HYBRID CONTROL)

A

2.CHECK BATTERY SMART UNIT (IGCT VOLTAGE)

B

2.CHECK BATTERY SMART UNIT (IGCT VOLTAGE)

OK

3.CHECK HARNESS AND CONNECTOR (HYBRID BATTERY JUNCTION BLOCK ASSEMBLY - BATTERY SMART UNIT)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR (BATTERY SMART UNIT POWER SOURCE CIRCUIT)

3.CHECK HARNESS AND CONNECTOR (HYBRID BATTERY JUNCTION BLOCK ASSEMBLY - BATTERY SMART UNIT)
NOTICE:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the No. 1 hybrid battery shield sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY SMART UNIT>REMOVAL).


c.

Remove the No. 2 hybrid battery shield sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV RELAY ASSEMBLY>REMOVAL).


d.

Disconnect only the d1 connector of the battery smart unit.


e.
A389837E01
2.26,0.969 2.604,1.156 0.344,0.188 2.354,0.99 2.667,1.188 0.313,0.198 10 false d2

Disconnect the d2 battery current sensor connector from the hybrid battery junction block assembly.


f.
U158972E03
1.594,1.667 2.292,1.188 false 1.979,3.76 2.594,3.708 false 1.479,1.667 1.844,1 false 1.531,3.844 0.917,3.188 false 1.469,1.833 1.083,2.135 false 1.771,3.75 2.427,3.188 false 1.125,1.125 1.354,1.323 0.229,0.198 10 false *a 1.156,2.698 1.385,2.896 0.229,0.198 10 false *b 2.365,1.083 2.594,1.271 0.229,0.188 10 false IB 2.656,3.615 2.885,3.802 0.229,0.188 10 false IB 1.906,0.896 2.177,1.083 0.271,0.188 10 false VIB 0.604,3.104 0.875,3.292 0.271,0.188 10 false VIB 0.781,2.063 1.073,2.26 0.292,0.198 10 false GIB 2.531,3.104 2.823,3.302 0.292,0.198 10 false GIB 0.708,1.573 0.896,1.719 0.188,0.146 10 false d1 0.677,3.604 0.906,3.75 0.229,0.146 10 false d2

Measure the resistance according to the value(s) in the tables below.

Standard Resistance (Check for Open):
Tester Connection Switch Condition Specified Condition
d1-5 (IB) - d2-3 (IB) Power switch off Below 1 Ω
d1-12 (GIB) - d2-2 (GIB) Power switch off Below 1 Ω
d1-6 (VIB) - d2-1 (VIB) Power switch off Below 1 Ω


Standard Resistance (Check for Short):
Tester Connection Switch Condition Specified Condition
d1-5 (IB) or d2-3 (IB) - Body ground and other terminals Power switch off 10 kΩ or higher
d1-12 (GIB) or d2-2 (GIB) - Body ground and other terminals Power switch off 10 kΩ or higher
d1-6 (VIB) or d2-1 (VIB) - Body ground and other terminals Power switch off 10 kΩ or higher


Text in Illustration
*a Rear view of wire harness connector
(to Battery Smart Unit)
*b Front view of wire harness connector
(to Hybrid Battery Junction Block Assembly)


HINT:

Because the battery harness is not available as a supply part, if the harness cannot be repaired, replace the HV battery assembly.


g.

Connect the battery smart unit connector.


h.

Connect the battery current sensor connector to the hybrid battery junction block assembly.


i.

Install the No. 2 hybrid battery shield sub-assembly.


j.

Install the No. 1 hybrid battery shield sub-assembly.



OK

4.CHECK BATTERY SMART UNIT (VIB VOLTAGE)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

4.CHECK BATTERY SMART UNIT (VIB VOLTAGE)
NOTICE:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the No. 1 hybrid battery shield sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY SMART UNIT>REMOVAL).


c.

Connect the cable to the negative (-) auxiliary battery terminal.


d.

Turn the power switch on (IG).


e.
U158965E03
0.583,0.448 0.917,0.885 true 0.917,0.969 0.625,1.719 true 0.115,0.073 0.302,0.24 0.188,0.167 10 false *a 0.302,0.375 0.552,0.615 0.25,0.24 10 false VIB 0.49,1.75 0.844,1.969 0.354,0.219 10 false GIB 1.01,0.146 1.313,0.333 0.302,0.188 10 false d1

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
d1-6 (VIB) - d1-12 (GIB) Power switch on (IG) 4.6 to 5.4 V


Text in Illustration
*a Component with harness connected
(Battery Smart Unit)


NOTICE:

Turning the power switch on (IG) with the service grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.


f.

Turn the power switch off.


g.

Disconnect the cable from the negative (-) auxiliary battery terminal.


h.

Install the No. 1 hybrid battery shield sub-assembly.



OK

5.CHECK BATTERY SMART UNIT

NG

5.CHECK BATTERY SMART UNIT
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the No. 1 hybrid battery shield sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY SMART UNIT>REMOVAL).


c.

Connect the cable to the negative (-) auxiliary battery terminal.


d.

Turn the power switch on (IG).


e.
U158966E03
0.979,0.896 1.771,0.365 true 0.917,0.969 0.625,1.719 true 0.115,0.083 0.302,0.25 0.188,0.167 10 false *a 1.813,0.281 2.063,0.521 0.25,0.24 10 false IB 0.49,1.75 0.969,1.969 0.479,0.219 10 false GIB 1.01,0.156 1.271,0.375 0.26,0.219 10 false d1

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
d1-5 (IB) - d1-12 (GIB) Power switch on (IG) 2.46 to 2.54 V


Text in Illustration
*a Component with harness connected
(Battery Smart Unit)


NOTICE:

Turning the power switch on (IG) with the service grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.


f.

Turn the power switch off.


g.

Disconnect the cable from the negative (-) auxiliary battery terminal.


h.

Install the No. 1 hybrid battery shield sub-assembly.



OK

NG

REPLACE HYBRID BATTERY JUNCTION BLOCK ASSEMBLY