Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID BATTERY SYSTEM › 2011.12–2014.12
RM2170E _51 Engine / Hybrid System _057004 HYBRID / BATTERY CONTROL _0277925 HYBRID BATTERY SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID BATTERY SYSTEM  P0A84-123  Hybrid Battery Pack Cooling Fan 1 Control Circuit Low  


DESCRIPTION

The speed of the battery cooling blower assembly is controlled by the power management control ECU. Power is supplied to the battery cooling blower assembly when the MREL terminal of the power management control ECU turns on the IGCT relay. The power management control ECU sends command signals (SI) to the battery cooling blower assembly to adjust the fan speed to an appropriate speed for the HV battery temperature. The battery cooling blower assembly frequency (FP) is sent to the power management control ECU via the battery smart unit as a monitor signal using serial communication.

A260101E31
0.49,0.094 2.563,0.531 2.073,0.438 10 false Battery Cooling Blower Assembly 2.792,0.958 3.875,1.271 1.083,0.313 10 false Command Signal 2.896,3.198 3.896,3.427 1,0.229 10 false Monitor Signal 4.708,0.438 5.948,0.823 1.24,0.385 10 false Power Management Control ECU 4.75,2.323 5.99,2.781 1.24,0.458 10 false Battery Smart Unit 3.896,1.729 5.281,2.01 1.385,0.281 10 false Serial Communication


DTC No. INF Code DTC Detection Condition Trouble Area
P0A84 123 When the speed calculated based on the battery cooling blower assembly frequency (FP) is out of the target control speed range (1 trip detection)
·

Wire harness or connector

·

BATT FAN fuse

·

Battery cooling blower assembly

·

Battery smart unit

·

Power management control ECU



WIRING DIAGRAM

A244326E13
5.802,4.76 7.146,5.115 1.344,0.354 10 false Power Management Control ECU 3.542,4.063 4.802,4.24 1.26,0.177 10 false Battery Smart Unit 4.01,3.302 4.396,3.438 0.385,0.135 10 false BTH+ 6.104,3.313 6.521,3.448 0.417,0.135 10 false BTH+ 2.094,1.083 2.792,1.302 0.698,0.219 10 false BATT FAN 4.104,2.969 4.406,3.188 0.302,0.219 10 false FP0 3.323,1.219 3.51,1.375 0.188,0.156 10 false 1 3.313,1.677 3.5,1.823 0.188,0.146 10 false 4 4.469,1.219 4.656,1.375 0.188,0.156 10 false 3 4.469,1.677 4.656,1.823 0.188,0.146 10 false 2 4.5,2.896 4.688,3.042 0.188,0.146 10 false 5 5.729,1.344 6.031,1.49 0.302,0.146 10 false A38 5.771,1.156 6.021,1.302 0.25,0.146 10 false 29 5.792,0.417 6.083,0.563 0.292,0.146 10 false 6 4.01,3.646 4.385,3.781 0.375,0.135 10 false BTH- 3.229,4.063 3.677,4.271 0.448,0.208 10 false M39 3.229,2.146 3.521,2.281 0.292,0.135 10 false M41 6.104,3.635 6.49,3.771 0.385,0.135 10 false BTH- 6.094,0.583 6.615,0.719 0.521,0.135 10 false MREL 5.771,3.156 6.063,3.396 0.292,0.24 10 false 32 4.5,3.552 4.75,3.698 0.25,0.146 10 false 4 3.542,2.146 4.667,2.469 1.125,0.323 10 false Battery Cooling Blower Assembly 6.104,1.313 6.375,1.521 0.271,0.208 10 false Sl0 6.104,4.354 6.396,4.563 0.292,0.208 10 false E02 6.104,3.99 6.51,4.25 0.406,0.26 10 false E01 5.729,0.604 6,0.802 0.271,0.198 10 false A39 5.813,4.188 6.042,4.354 0.229,0.167 10 false 5 4.5,3.219 4.75,3.365 0.25,0.146 10 false 1 4.104,1.771 4.385,1.938 0.281,0.167 10 false FP0 4.125,1.313 4.406,1.479 0.281,0.167 10 false Sl0 3.5,1.323 3.781,1.49 0.281,0.167 10 false IG0 3.5,1.771 3.906,1.938 0.406,0.167 10 false GND0 5.729,3.323 6.031,3.469 0.302,0.146 10 false G57 5.719,3.646 6.063,3.792 0.344,0.146 10 false G57 5.771,3.49 6.063,3.729 0.292,0.24 10 false 33 5.708,4.365 6.052,4.51 0.344,0.146 10 false G58 5.813,3.833 6.042,4 0.229,0.167 10 false 5 5.708,4 6.031,4.146 0.323,0.146 10 false G57 1.01,4.198 2.313,4.385 1.302,0.188 10 false Auxiliary Battery 0.865,2.063 1.792,2.26 0.927,0.198 10 false IGCT-MAIN 1.219,1.25 1.625,1.448 0.406,0.198 10 false IGCT 1.75,0.49 1.938,0.646 0.188,0.156 10 false 1 0.948,0.49 1.135,0.635 0.188,0.146 10 false 2 0.958,0.823 1.146,0.979 0.188,0.156 10 false 3 1.75,0.833 1.979,1 0.229,0.167 10 false 5 2.177,0.802 2.365,0.958 0.188,0.156 10 false 1 2.594,0.802 2.781,0.958 0.188,0.156 10 false 2 0.865,3.104 1.604,3.302 0.74,0.198 10 false MAIN 0.625,2.25 0.813,2.406 0.188,0.156 10 false 1 0.635,1.854 0.823,2.01 0.188,0.156 10 false 2

CAUTION / NOTICE / HINT

CAUTION:
·

Before inspecting the high-voltage system, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·

After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>PRECAUTION).

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.




NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).


PROCEDURE

1.CHECK FOR DTCS (HV)

A

2.PERFORM ACTIVE TEST USING INTELLIGENT TESTER

B

2.PERFORM ACTIVE TEST USING INTELLIGENT TESTER
a.

Connect the intelligent tester to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / Active Test / Driving the Battery Cooling Fan.

NOTICE:

If the Active Test cannot be performed, skip it and proceed to the next step to check fan operates and air is sucked. In accordance with fail-safe system operation, the power management control ECU sends a command to operate the battery cooling fan.



d.

Select air volume mode 6 in the "Driving the Battery Cooling Fan" Active Test to operate the battery cooling blower assembly.


e.

Check that the fan operates and air is sucked into the inlet duct.

HINT:

The cooling fan may not stop even when turning the cooling fan off in the "Driving the Battery Cooling Fan" Active Test. This is due to HV system control and not a malfunction.


OK:

The fan operates.



f.

Turn the power switch off.



OK

3.CHECK HARNESS AND CONNECTOR (BATTERY COOLING BLOWER - BATTERY SMART UNIT)

NG

7.CHECK FUSE (BATT FAN)
3.CHECK HARNESS AND CONNECTOR (BATTERY COOLING BLOWER - BATTERY SMART UNIT)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the No. 1 hybrid battery exhaust duct (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY SMART UNIT>REMOVAL).


c.

Disconnect connector M41 from the battery cooling blower assembly.


d.

Disconnect connector M39 from the battery smart unit.


e.
U158961E03
1.792,0.802 2.281,0.552 false 1.208,3.615 1.656,4.052 false 2.333,0.469 2.604,0.729 0.271,0.26 10 false FP0 0.99,0.083 1.323,0.323 0.333,0.24 10 false *a 1.031,1.76 1.365,2 0.333,0.24 10 false *b 1.729,3.979 2.083,4.25 0.354,0.271 10 false FP0 0.823,0.771 1.177,0.917 0.354,0.146 10 false M41 0.396,3.406 0.708,3.552 0.313,0.146 10 false M39

Measure the resistance according to the value(s) in the table below.

Standard Resistance (Check for Open):
Tester Connection Switch Condition Specified Condition
M41-2 (FP0) - M39-5 (FP0) Power switch off Below 1 Ω
M41-2 (FP0) or M39-5 (FP0) - Body ground Power switch off 10 kΩ or higher


Text in Illustration
*a Front view of wire harness connector
(to Battery Cooling Blower Assembly)
*b Rear view of wire harness connector
(to Battery Smart Unit)


f.

Connect the cable to the negative (-) auxiliary battery terminal.


g.

Turn the power switch on (IG).


h.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
M41-2 (FP0) - Body ground Power switch on (IG) Below 1 V


NOTICE:

Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.


HINT:

As there might be an intermittent malfunction, inspect the following items even if the measured voltage is as specified. Check that each connector between the battery voltage sensor and battery cooling blower assembly is not loose or disconnected.



i.

Turn the power switch off.


j.

Disconnect the cable from the negative (-) auxiliary battery terminal.


k.

Connect the battery cooling blower assembly connector.


l.

Connect the battery smart unit connector.


m.

Install the No. 1 hybrid battery exhaust duct.



OK

4.READ VALUE USING INTELLIGENT TESTER (COOLING FAN FREQUENCY)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR (BATTERY COOLING BLOWER - BATTERY SMART UNIT)

4.READ VALUE USING INTELLIGENT TESTER (COOLING FAN FREQUENCY)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the rear seat cushion leg sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY SMART UNIT>REMOVAL).


c.

Connect the cable to the negative (-) auxiliary battery terminal.


d.

Connect the intelligent tester to the DLC3.


e.

Turn the power switch on (IG).


f.

Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.



h.

Enter the following menus: Powertrain / Hybrid Control / Active Test / Driving the Battery Cooling Fan.


i.

Enter the following menus: Powertrain / Hybrid Control / Data List / All Data / Cooling Fan Frequency 1.


j.

Select each air volume mode (1 to 6) in the "Driving the Battery Cooling Fan" Active Test to operate the battery cooling blower assembly.

NOTICE:

If the Active Test cannot be performed, skip it and proceed to the next step to check the frequency value. In accordance with fail-safe system operation, the power management control ECU sends a command to operate the battery cooling fan assembly.



k.
U159014E03
0.896,0.833 0.563,0.615 false 0.615,1.188 0.906,1.063 false 0.146,1.667 0.5,1.917 0.354,0.25 10 false *a 0.26,0.5 0.75,0.75 0.49,0.25 10 false FP0 0.198,1.156 0.646,1.406 0.448,0.25 10 false GND0 2.25,0.344 2.729,0.688 0.479,0.344 10 false M41 0.198,0.167 0.552,0.417 0.354,0.25 10 false *b

While the cooling fan is operating, compare the value in the Data List (Cooling Fan Frequency1) with the frequency value that was actually measured at the battery cooling blower assembly connector.

Standard:
Tester Connection Condition
M41-2 (FP0) - M41-4 (GND0) Battery cooling blower assembly is operating


Text in Illustration
*a Component with harness connected
(Battery Cooling Blower Assembly)
*b Rear view of wire harness connector
(to Battery Cooling Blower Assembly)

Result:
Result Proceed to
The value in the Data List (Cooling Fan Frequency 1) and the actual measurement value at the battery cooling blower assembly connector are 0 Hz. A
The value in the Data List (Cooling Fan Frequency 1) and the actual measurement value at the battery cooling blower assembly connector are not 0 Hz. B


NOTICE:

Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.


HINT:

Compare the values in each air volume mode (1 to 6). If the Active Test cannot be performed, compare the values only in the current air volume mode.



l.

Turn the power switch off.


m.

Disconnect the cable from the negative (-) auxiliary battery terminal.


n.

Install the rear seat cushion leg sub-assembly.



A

5.CHECK BATTERY SMART UNIT

B

6.CHECK BATTERY SMART UNIT (FREQUENCY)
5.CHECK BATTERY SMART UNIT
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the rear seat cushion leg sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY SMART UNIT>REMOVAL).


c.

Disconnect connector M41 from the battery cooling blower assembly.


d.

Connect the cable to the negative (-) auxiliary battery terminal.


e.

Turn the Turn the power switch on (IG)..

NOTICE:
·

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

·

If the power switch is turned on (IG) with the service plug grip removed, DTC P0A0D-350 for the interlock switch system will be stored. If this DTC is output, clear the DTC using the intelligent tester (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>DTC CHECK / CLEAR).




f.
U159132E01
0.675,1.024 0.995,1.187 0.320,0.163 10 M41 2.515,1.528 2.968,1.690 0.452,0.163 10 GND0 1.822,1.279 2.476,1.593 false 2.515,0.714 2.801,0.877 0.286,0.163 10 FP0 1.822,1.092 2.476,0.779 false 0.119,0.056 0.439,0.219 0.320,0.163 10 *a

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
M41-2 (FP0) - M41-4 (GND0) Power switch on (IG) 4.5 to 5.5 V


Text in Illustration
*a Front view of wire harness connector
(to Battery Cooling Blower Assembly)

NOTICE:

Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.



g.

Turn the power switch off.


h.

Disconnect the cable from the negative (-) auxiliary battery terminal.


i.

Connect the battery cooling blower assembly connector.


j.

Install the rear seat cushion leg sub-assembly.



OK

REPLACE BATTERY COOLING BLOWER ASSEMBLY

NG

7.CHECK FUSE (BATT FAN)
a.

Remove the BATT FAN fuse from the No. 2 engine room relay block and No. 2 junction block assembly.


b.
A244331E02
2.5,2.052 2.729,2.781 false 0.115,0.052 0.323,0.24 0.208,0.188 10 false *1 2.656,2.823 2.865,3.01 0.208,0.188 10 false *2

Measure the resistance of the BATT FAN fuse.

Standard Resistance:
Tester Connection Condition Specified Condition
BATT FAN fuse Always Below 1 Ω


Text in Illustration
*1 No. 2 Engine Room Relay Block and No. 2 Junction Block Assembly
*2 BATT FAN Fuse



OK

8.CHECK HARNESS AND CONNECTOR (IGCT RELAY - BATTERY COOLING BLOWER ASSEMBLY) (VOLTAGE)

NG

17.CHECK HARNESS AND CONNECTOR (BATT FAN FUSE - BATTERY COOLING BLOWER ASSEMBLY)
8.CHECK HARNESS AND CONNECTOR (IGCT RELAY - BATTERY COOLING BLOWER ASSEMBLY) (VOLTAGE)
a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the rear seat cushion leg sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY SMART UNIT>REMOVAL).


c.

Connect the cable to the negative (-) auxiliary battery terminal.


d.

Connect the intelligent tester to the DLC3.


e.

Turn the power switch on (IG).

NOTICE:
·

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

·

If the power switch is turned on (IG) with the service plug grip removed, DTC P0A0D-350 for the interlock switch system will be stored. If this DTC is output, clear the DTC using the intelligent tester (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>DTC CHECK / CLEAR).




f.

Enter the following menus: Powertrain / Hybrid Control / DTC.



h.
U159015C01
0.542,1.302 0.906,1.073 true 1.094,0.854 1.458,0.625 true 0.167,1.615 0.521,1.865 0.354,0.25 10 false *a 1.521,0.542 1.802,0.792 0.281,0.25 10 false IG0 2.25,0.333 2.563,0.479 0.313,0.146 10 false M41 0.188,0.135 0.542,0.385 0.354,0.25 10 false *b 0.292,1.333 0.99,1.74 0.698,0.406 10 false GND0
*a Component with harness connected
(Battery Cooling Blower Assembly)
*b Rear view of wire harness connector
(to Battery Cooling Blower Assembly)


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
M41-1 (IG0) - M41-4 (GND0) Power switch on (IG) 11 to 14 V


NOTICE:

Turning the power switch on (IG) with the service grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.


HINT:

Measure the voltage on the wire side of the connector that is part of the battery cooling blower.



i.

Turn the power switch off.


j.

Disconnect the cable from the negative (-) auxiliary battery terminal.


k.

Install the rear seat cushion leg sub-assembly.



OK

9.CHECK HARNESS AND CONNECTOR (BATTERY COOLING BLOWER - POWER MANAGEMENT CONTROL ECU)

NG

13.CHECK HARNESS AND CONNECTOR (BATTERY COOLING BLOWER ASSEMBLY - BODY GROUND)
9.CHECK HARNESS AND CONNECTOR (BATTERY COOLING BLOWER - POWER MANAGEMENT CONTROL ECU)
a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the rear seat cushion leg sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY SMART UNIT>REMOVAL).


c.

Disconnect connector M41 from the battery cooling blower assembly.


d.

Disconnect connector A38 from the power management control ECU (See page Power Source / Network>POWER DISTRIBUTION>POWER MANAGEMENT CONTROL ECU>REMOVAL).


e.
U183231E02
1.635,0.917 0.781,1.167 false 1.521,3.698 2.146,3.99 false 0.938,0.073 1.094,0.354 0.156,0.281 10 false *a 0.521,1.125 1.021,1.354 0.5,0.229 10 false SI0 0.76,1.656 0.917,1.938 0.156,0.281 10 false *b 2.219,3.948 2.719,4.177 0.5,0.229 10 false SI0 2.385,0.635 2.719,0.833 0.333,0.198 10 false M41 1.906,3.344 2.208,3.51 0.302,0.167 10 false A38

Measure the resistance according to the value(s) in the table below.

Standard Resistance (Check for Open):
Tester Connection Switch Condition Specified Condition
M41-3 (SI0) - A38-29 (SI0) Power switch off Below 1 Ω
M41-3 (SI0) or A38-29 (SI0) - Body ground Power switch off 10 kΩ or higher


Text in Illustration
*a Front view of wire harness connector
(to Battery Cooling Blower Assembly)
*b Rear view of wire harness connector
(to Power Management Control ECU)

NOTICE:

When taking a measurement with a tester, do not apply excessive force to the tester probe to avoid damaging the holder.



f.

Connect the cable to the negative (-) auxiliary battery terminal.


g.

Turn the power switch on (IG).


h.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
M41-3 (SI0) - Body ground Power switch on (IG) Below 1 V



NOTICE:

Turning the power switch on (IG) with the battery cooling blower assembly connector and power management control ECU connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.


i.

Turn the power switch off.


j.

Disconnect the cable from the negative (-) auxiliary battery terminal.


k.

Connect the battery cooling blower assembly connector.


l.

Install the rear seat cushion leg sub-assembly.


m.

Connect the power management control ECU connector.



OK

10.CHECK POWER MANAGEMENT CONTROL ECU

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

10.CHECK POWER MANAGEMENT CONTROL ECU
a.

Remove the power management control ECU.

Click herePower Source / Network>POWER DISTRIBUTION>POWER MANAGEMENT CONTROL ECU>REMOVAL


b.
A409192C03
1.833,0.375 2.25,0.635 0.417,0.26 0.583,0.365 1,0.625 0.417,0.26 0.979,1.74 0.979,1.25 true 2.604,1.823 2.25,1.823 2.25,1.823 1.896,1.031 true 0.167,0.052 0.531,0.417 0.365,0.365 10 false *a 0.896,1.771 1.552,2.083 0.656,0.313 10 false SI0 2.677,1.74 3.333,2.052 0.656,0.313 10 false E01 1.906,0.427 2.563,0.74 0.656,0.313 10 false G57 0.656,0.396 1.313,0.708 0.656,0.313 10 false A38
*a Component without harness connected
(Power Management Control ECU)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Specified Condition
A38-29 (SI0) - G57-5 (E01) 10 kΩ or higher



c.

Install the hybrid vehicle control ECU.



OK

11.CHECK POWER MANAGEMENT CONTROL ECU (SI0 VOLTAGE)

NG

11.CHECK POWER MANAGEMENT CONTROL ECU (SI0 VOLTAGE)
a.

Turn the power switch on (IG).


b.
A249750C81
0.552,0.896 1.01,1.156 0.458,0.26 1.813,0.885 2.292,1.146 0.479,0.26 0.958,1.917 0.688,2.917 true 1.896,1.698 2.333,2.979 2.333,2.979 2.583,2.979 true 0.667,0.938 1.073,1.156 0.406,0.219 10 false A38 0.219,0.208 0.885,0.958 0.667,0.75 10 false *a 2.656,2.896 3.313,3.333 0.656,0.438 10 false E01 0.573,2.979 1.115,3.354 0.542,0.375 10 false SI0 1.958,0.917 2.365,1.135 0.406,0.219 10 false G57
*a Component with harness connected
(Power Management Control ECU)


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
A38-29 (SI0) - G57-5 (E01) Power switch on (IG) 4.5 to 5.5 V



c.

Turn the power switch off.



OK

12.CHECK BATTERY COOLING BLOWER ASSEMBLY

NG

REPLACE BATTERY COOLING BLOWER ASSEMBLY

12.CHECK BATTERY COOLING BLOWER ASSEMBLY
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the rear seat cushion leg sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY SMART UNIT>REMOVAL).


c.

Connect the cable to the negative (-) auxiliary battery terminal.


d.

Connect the intelligent tester to the DLC3.


e.

Turn the power switch on (IG).


f.

Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.



h.

Enter the following menus: Powertrain / Hybrid Control / Active Test / Driving the Battery Cooling Fan.


i.

Select each air volume mode (1 to 6) in the "Driving the Battery Cooling Fan" Active Test to operate the battery cooling blower assembly.

NOTICE:

If the Active Test cannot be performed, skip it and proceed to the next step to check the waveform. In accordance with fail-safe system operation, the power management control ECU sends a command to operate the battery cooling blower assembly.



j.

Connect an oscilloscope between the battery cooling blower assembly terminals specified in the following table.


k.
U159016E03
1.469,1.146 1.115,1.052 false 0.646,1.115 0.917,1.052 false 0.167,1.615 0.521,1.865 0.354,0.25 10 false *a 1.531,1.094 2.021,1.344 0.49,0.25 10 false SI0 0.208,1.052 0.656,1.302 0.448,0.25 10 false GND0 2.25,0.323 2.563,0.469 0.313,0.146 10 false M41 0.188,0.125 0.542,0.375 0.354,0.25 10 false *b

Check the waveform.

Specified Condition:
Tester Connection Switch Condition Specified Condition
M41-3 (SI0) - M41-4 (GND0) Power switch on (IG), during Active Test Pulse generation

Text in Illustration
*a Component with harness connected
(Battery Cooling Blower Assembly)
*b Rear view of wire harness connector
(to Battery Cooling Blower Assembly)


NOTICE:

Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.


HINT:

Perform this inspection with the battery cooling blower assembly connector connected.



l.

Turn the power switch off.


m.

Disconnect the cable from the negative (-) auxiliary battery terminal.


n.

Install the rear seat cushion leg sub-assembly.



OK

REPLACE BATTERY COOLING BLOWER ASSEMBLY

NG

13.CHECK HARNESS AND CONNECTOR (BATTERY COOLING BLOWER ASSEMBLY - BODY GROUND)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the rear seat cushion leg sub-assembly.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY SMART UNIT>REMOVAL


c.
U124281C03
1.708,1.469 2.115,1.198 false 0.167,0.135 0.521,0.385 0.354,0.25 10 false *a 0.854,0.323 1.24,0.573 0.385,0.25 10 false M41 1.417,0.302 1.771,0.552 0.354,0.25 10 false *b 1.458,1.49 2.104,1.823 0.646,0.333 10 false GND0
*a Component with harness connected
(Battery Cooling Blower Assembly)
*b Rear view of wire harness connector
(Battery Cooling Blower Assembly)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
M41-4 (GND0) - Body ground Power switch off Below 1 Ω



d.

Install the rear seat cushion leg sub-assembly.



OK

14.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - BODY GROUND)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

14.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - BODY GROUND)
a.

Disconnect connector G57 from the power management control ECU (See page Power Source / Network>POWER DISTRIBUTION>POWER MANAGEMENT CONTROL ECU>REMOVAL).


b.
U158854E02
1.875,2.656 1.323,2.958 true 0.573,0.51 1,0.802 0.427,0.292 10 false *a 2.469,2.625 2.781,2.885 0.313,0.26 10 false G57 1.01,2.875 1.396,3.083 0.385,0.208 10 false E01

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Switch Condition Specified Condition
G57-5 (E01) - Body ground Power switch off Below 1 Ω


Text in Illustration
*a Rear view of wire harness connector
(to Power Management Control ECU)

NOTICE:

When taking a measurement with a tester, do not apply excessive force to the tester probe to avoid damaging the holder.



c.

Connect the power management control ECU connector.



OK

15.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - BODY GROUND)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

15.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - BODY GROUND)
a.

Disconnect connector G58 from the power management control ECU (See page Power Source / Network>POWER DISTRIBUTION>POWER MANAGEMENT CONTROL ECU>REMOVAL).


b.
U158855E02
2.521,2.479 1.688,2.729 true 0.583,0.458 1,0.708 0.417,0.25 10 false *a 3.021,2.427 3.323,2.615 0.302,0.188 10 false G58 1.333,2.667 1.646,2.865 0.313,0.198 10 false E02

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Switch Condition Specified Condition
G58-5 (E02) - Body ground Power switch off Below 1 Ω


Text in Illustration
*a Rear view of wire harness connector
(to Power Management Control ECU)

NOTICE:

When taking a measurement with a tester, do not apply excessive force to the tester probe to avoid damaging the holder.



c.

Connect the power management control ECU connector.



OK

16.CHECK HARNESS AND CONNECTOR (IGCT RELAY - BATTERY COOLING BLOWER ASSEMBLY)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

16.CHECK HARNESS AND CONNECTOR (IGCT RELAY - BATTERY COOLING BLOWER ASSEMBLY)
a.

Remove the IGCT relay.


b.

Remove the rear seat cushion leg sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY SMART UNIT>REMOVAL).


c.

Disconnect connector M41 from the battery cooling blower assembly.


d.
U158908E03
1.594,1 1.177,0.833 false 0.885,0.25 1.083,0.51 0.198,0.26 10 false *a 0.854,0.74 1.135,0.99 0.281,0.25 10 false IG0 0.104,1.792 0.302,2.052 0.198,0.26 10 false *1 2.24,1 2.656,1.198 0.417,0.198 10 false M41 2.792,1.594 2.99,1.854 0.198,0.26 10 false *2

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Switch Condition Specified Condition
5 (IGCT relay block) - M41-1 (IG0) Power switch off Below 1 Ω


Text in Illustration
*1 No. 2 Engine Room Relay Block and No. 2 Junction Block Assembly
*2 IGCT Relay
*a Front view of wire harness connector
(to Battery Cooling Blower Assembly)


e.

Install the IGCT relay.


f.

Connect the battery cooling blower assembly connector.


g.

Install the rear seat cushion leg sub-assembly.



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

17.CHECK HARNESS AND CONNECTOR (BATT FAN FUSE - BATTERY COOLING BLOWER ASSEMBLY)
a.

Remove the BATT FAN fuse.


b.

Remove the rear seat cushion leg sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY SMART UNIT>REMOVAL).


c.

Disconnect connector M41 from the battery cooling blower assembly.


d.
U158907E03
1.594,0.813 1.167,0.719 false 1.052,0.104 1.25,0.365 0.198,0.26 10 false *a 0.833,0.615 1.115,0.865 0.281,0.25 10 false IG0 0.167,1.885 0.365,2.146 0.198,0.26 10 false *1 2.281,0.813 2.635,0.958 0.354,0.146 10 false M41 3.052,3.75 3.25,4.01 0.198,0.26 10 false *2

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Switch Condition Specified Condition
M41-1 (IG0) - Terminals other than 2 (BATT FAN fuse block) and body ground Power switch off 10 kΩ or higher


Text in Illustration
*1 No. 2 Engine Room Relay Block and No. 2 Junction Block Assembly
*2 BATT FAN fuse
*a Front view of wire harness connector
(to Battery Cooling Blower Assembly)


e.

Install the BATT FAN fuse.


f.

Connect the battery cooling blower assembly connector.


g.

Install the rear seat cushion leg sub-assembly.



OK

18.CHECK BATTERY COOLING BLOWER ASSEMBLY

NG

19.REPAIR OR REPLACE HARNESS OR CONNECTOR
18.CHECK BATTERY COOLING BLOWER ASSEMBLY
a.

Remove the rear seat cushion leg sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY SMART UNIT>REMOVAL).


b.

Disconnect connector M41 from the battery cooling blower assembly.


c.
U158902E03
1.781,1.135 2.406,0.646 true 1.51,1.406 0.906,1.688 true 0.573,0.042 0.74,0.25 0.167,0.208 10 false *a 0.615,0.625 0.99,0.885 0.375,0.26 10 false M41 2.479,0.542 2.771,0.75 0.292,0.208 10 false IG0 0.458,1.615 0.896,1.823 0.438,0.208 10 false GND0

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Switch Condition Specified Condition
M41-1 (IG0) - M41-4 (GND0) and body ground Power switch off 10 kΩ or higher


Text in Illustration
*a Component without harness connected
(Battery Cooling Blower Assembly)


d.

Connect the battery cooling blower assembly connector.


e.

Install the rear seat cushion leg sub-assembly.



OK

REPLACE FUSE (BATT FAN)

NG

20.REPLACE BATTERY COOLING BLOWER ASSEMBLY
19.REPAIR OR REPLACE HARNESS OR CONNECTOR

NEXT

REPLACE FUSE (BATT FAN)

20.REPLACE BATTERY COOLING BLOWER ASSEMBLY

NEXT

REPLACE FUSE (BATT FAN)