The speed of the battery cooling blower assembly is controlled by the power management control ECU. Power is supplied to the battery cooling blower assembly when the MREL terminal of the power management control ECU turns on the IGCT relay. The power management control ECU sends command signals (SI) to the battery cooling blower assembly to adjust the fan speed to an appropriate speed for the HV battery temperature. The battery cooling blower assembly frequency (FP) is sent to the power management control ECU via the battery smart unit as a monitor signal using serial communication.
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| P0A84 | 123 | When the speed calculated based on the battery cooling blower assembly frequency (FP) is out of the target control speed range (1 trip detection) | ·
Wire harness or connector ·
BATT FAN fuse ·
Battery cooling blower assembly ·
Battery smart unit ·
Power management control ECU |
Before inspecting the high-voltage system, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>PRECAUTION).
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).
A
B
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Active Test / Driving the Battery Cooling Fan.
If the Active Test cannot be performed, skip it and proceed to the next step to check fan operates and air is sucked. In accordance with fail-safe system operation, the power management control ECU sends a command to operate the battery cooling fan.
Select air volume mode 6 in the "Driving the Battery Cooling Fan" Active Test to operate the battery cooling blower assembly.
Check that the fan operates and air is sucked into the inlet duct.
The cooling fan may not stop even when turning the cooling fan off in the "Driving the Battery Cooling Fan" Active Test. This is due to HV system control and not a malfunction.
The fan operates.
Turn the power switch off.
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 1 hybrid battery exhaust duct (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY SMART UNIT>REMOVAL).
Disconnect connector M41 from the battery cooling blower assembly.
Disconnect connector M39 from the battery smart unit.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| M41-2 (FP0) - M39-5 (FP0) | Power switch off | Below 1 Ω |
| M41-2 (FP0) or M39-5 (FP0) - Body ground | Power switch off | 10 kΩ or higher |
| *a | Front view of wire harness connector
(to Battery Cooling Blower Assembly) |
| *b | Rear view of wire harness connector
(to Battery Smart Unit) |
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| M41-2 (FP0) - Body ground | Power switch on (IG) | Below 1 V |
Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
As there might be an intermittent malfunction, inspect the following items even if the measured voltage is as specified. Check that each connector between the battery voltage sensor and battery cooling blower assembly is not loose or disconnected.
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Connect the battery cooling blower assembly connector.
Connect the battery smart unit connector.
Install the No. 1 hybrid battery exhaust duct.
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the rear seat cushion leg sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY SMART UNIT>REMOVAL).
Connect the cable to the negative (-) auxiliary battery terminal.
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Clear the DTCs and freeze frame data (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>DTC CHECK / CLEAR).
Enter the following menus: Powertrain / Hybrid Control / Active Test / Driving the Battery Cooling Fan.
Enter the following menus: Powertrain / Hybrid Control / Data List / All Data / Cooling Fan Frequency 1.
Select each air volume mode (1 to 6) in the "Driving the Battery Cooling Fan" Active Test to operate the battery cooling blower assembly.
If the Active Test cannot be performed, skip it and proceed to the next step to check the frequency value. In accordance with fail-safe system operation, the power management control ECU sends a command to operate the battery cooling fan assembly.
While the cooling fan is operating, compare the value in the Data List (Cooling Fan Frequency1) with the frequency value that was actually measured at the battery cooling blower assembly connector.
| Tester Connection | Condition |
|---|---|
| M41-2 (FP0) - M41-4 (GND0) | Battery cooling blower assembly is operating |
| *a | Component with harness connected
(Battery Cooling Blower Assembly) |
| *b | Rear view of wire harness connector
(to Battery Cooling Blower Assembly) |
| Result | Proceed to |
|---|---|
| The value in the Data List (Cooling Fan Frequency 1) and the actual measurement value at the battery cooling blower assembly connector are 0 Hz. | A |
| The value in the Data List (Cooling Fan Frequency 1) and the actual measurement value at the battery cooling blower assembly connector are not 0 Hz. | B |
Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Compare the values in each air volume mode (1 to 6). If the Active Test cannot be performed, compare the values only in the current air volume mode.
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Install the rear seat cushion leg sub-assembly.
A
B
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the rear seat cushion leg sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY SMART UNIT>REMOVAL).
Disconnect connector M41 from the battery cooling blower assembly.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the Turn the power switch on (IG)..
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
If the power switch is turned on (IG) with the service plug grip removed, DTC P0A0D-350 for the interlock switch system will be stored. If this DTC is output, clear the DTC using the intelligent tester (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>DTC CHECK / CLEAR).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| M41-2 (FP0) - M41-4 (GND0) | Power switch on (IG) | 4.5 to 5.5 V |
| *a | Front view of wire harness connector
(to Battery Cooling Blower Assembly) |
Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Connect the battery cooling blower assembly connector.
Install the rear seat cushion leg sub-assembly.
OK
NG
OK
NG
Remove the BATT FAN fuse from the No. 2 engine room relay block and No. 2 junction block assembly.
Measure the resistance of the BATT FAN fuse.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| BATT FAN fuse | Always | Below 1 Ω |
| *1 | No. 2 Engine Room Relay Block and No. 2 Junction Block Assembly |
| *2 | BATT FAN Fuse |
OK
NG
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the rear seat cushion leg sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY SMART UNIT>REMOVAL).
Connect the cable to the negative (-) auxiliary battery terminal.
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
If the power switch is turned on (IG) with the service plug grip removed, DTC P0A0D-350 for the interlock switch system will be stored. If this DTC is output, clear the DTC using the intelligent tester (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>DTC CHECK / CLEAR).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Clear the DTCs and freeze frame data (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>DTC CHECK / CLEAR).
| *a | Component with harness connected
(Battery Cooling Blower Assembly) |
| *b | Rear view of wire harness connector
(to Battery Cooling Blower Assembly) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| M41-1 (IG0) - M41-4 (GND0) | Power switch on (IG) | 11 to 14 V |
Turning the power switch on (IG) with the service grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Measure the voltage on the wire side of the connector that is part of the battery cooling blower.
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Install the rear seat cushion leg sub-assembly.
OK
NG
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the rear seat cushion leg sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY SMART UNIT>REMOVAL).
Disconnect connector M41 from the battery cooling blower assembly.
Disconnect connector A38 from the power management control ECU (See page Power Source / Network>POWER DISTRIBUTION>POWER MANAGEMENT CONTROL ECU>REMOVAL).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| M41-3 (SI0) - A38-29 (SI0) | Power switch off | Below 1 Ω |
| M41-3 (SI0) or A38-29 (SI0) - Body ground | Power switch off | 10 kΩ or higher |
| *a | Front view of wire harness connector
(to Battery Cooling Blower Assembly) |
| *b | Rear view of wire harness connector
(to Power Management Control ECU) |
When taking a measurement with a tester, do not apply excessive force to the tester probe to avoid damaging the holder.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| M41-3 (SI0) - Body ground | Power switch on (IG) | Below 1 V |
Turning the power switch on (IG) with the battery cooling blower assembly connector and power management control ECU connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Connect the battery cooling blower assembly connector.
Install the rear seat cushion leg sub-assembly.
Connect the power management control ECU connector.
OK
NG
Remove the power management control ECU.
Click herePower Source / Network>POWER DISTRIBUTION>POWER MANAGEMENT CONTROL ECU>REMOVAL
| *a | Component without harness connected
(Power Management Control ECU) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
|---|---|
| A38-29 (SI0) - G57-5 (E01) | 10 kΩ or higher |
Install the hybrid vehicle control ECU.
OK
NG
Turn the power switch on (IG).
| *a | Component with harness connected
(Power Management Control ECU) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A38-29 (SI0) - G57-5 (E01) | Power switch on (IG) | 4.5 to 5.5 V |
Turn the power switch off.
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the rear seat cushion leg sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY SMART UNIT>REMOVAL).
Connect the cable to the negative (-) auxiliary battery terminal.
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Clear the DTCs and freeze frame data (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>DTC CHECK / CLEAR).
Enter the following menus: Powertrain / Hybrid Control / Active Test / Driving the Battery Cooling Fan.
Select each air volume mode (1 to 6) in the "Driving the Battery Cooling Fan" Active Test to operate the battery cooling blower assembly.
If the Active Test cannot be performed, skip it and proceed to the next step to check the waveform. In accordance with fail-safe system operation, the power management control ECU sends a command to operate the battery cooling blower assembly.
Connect an oscilloscope between the battery cooling blower assembly terminals specified in the following table.
Check the waveform.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| M41-3 (SI0) - M41-4 (GND0) | Power switch on (IG), during Active Test | Pulse generation |
| *a | Component with harness connected
(Battery Cooling Blower Assembly) |
| *b | Rear view of wire harness connector
(to Battery Cooling Blower Assembly) |
Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Perform this inspection with the battery cooling blower assembly connector connected.
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Install the rear seat cushion leg sub-assembly.
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the rear seat cushion leg sub-assembly.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY SMART UNIT>REMOVAL
| *a | Component with harness connected
(Battery Cooling Blower Assembly) |
| *b | Rear view of wire harness connector
(Battery Cooling Blower Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| M41-4 (GND0) - Body ground | Power switch off | Below 1 Ω |
Install the rear seat cushion leg sub-assembly.
OK
NG
Disconnect connector G57 from the power management control ECU (See page Power Source / Network>POWER DISTRIBUTION>POWER MANAGEMENT CONTROL ECU>REMOVAL).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| G57-5 (E01) - Body ground | Power switch off | Below 1 Ω |
| *a | Rear view of wire harness connector
(to Power Management Control ECU) |
When taking a measurement with a tester, do not apply excessive force to the tester probe to avoid damaging the holder.
Connect the power management control ECU connector.
OK
NG
Disconnect connector G58 from the power management control ECU (See page Power Source / Network>POWER DISTRIBUTION>POWER MANAGEMENT CONTROL ECU>REMOVAL).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| G58-5 (E02) - Body ground | Power switch off | Below 1 Ω |
| *a | Rear view of wire harness connector
(to Power Management Control ECU) |
When taking a measurement with a tester, do not apply excessive force to the tester probe to avoid damaging the holder.
Connect the power management control ECU connector.
OK
NG
Remove the IGCT relay.
Remove the rear seat cushion leg sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY SMART UNIT>REMOVAL).
Disconnect connector M41 from the battery cooling blower assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 5 (IGCT relay block) - M41-1 (IG0) | Power switch off | Below 1 Ω |
| *1 | No. 2 Engine Room Relay Block and No. 2 Junction Block Assembly |
| *2 | IGCT Relay |
| *a | Front view of wire harness connector
(to Battery Cooling Blower Assembly) |
Install the IGCT relay.
Connect the battery cooling blower assembly connector.
Install the rear seat cushion leg sub-assembly.
OK
NG
Remove the BATT FAN fuse.
Remove the rear seat cushion leg sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY SMART UNIT>REMOVAL).
Disconnect connector M41 from the battery cooling blower assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| M41-1 (IG0) - Terminals other than 2 (BATT FAN fuse block) and body ground | Power switch off | 10 kΩ or higher |
| *1 | No. 2 Engine Room Relay Block and No. 2 Junction Block Assembly |
| *2 | BATT FAN fuse |
| *a | Front view of wire harness connector
(to Battery Cooling Blower Assembly) |
Install the BATT FAN fuse.
Connect the battery cooling blower assembly connector.
Install the rear seat cushion leg sub-assembly.
OK
NG
Remove the rear seat cushion leg sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY SMART UNIT>REMOVAL).
Disconnect connector M41 from the battery cooling blower assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| M41-1 (IG0) - M41-4 (GND0) and body ground | Power switch off | 10 kΩ or higher |
| *a | Component without harness connected
(Battery Cooling Blower Assembly) |
Connect the battery cooling blower assembly connector.
Install the rear seat cushion leg sub-assembly.
OK
NG
NEXT
NEXT