Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › INVERTER WITH CONVERTER › 2011.12–2014.12
RM2170E _51 Engine / Hybrid System _057004 HYBRID / BATTERY CONTROL _0277927 INVERTER WITH CONVERTER A

HYBRID / BATTERY CONTROL  INVERTER WITH CONVERTER  INSTALLATION  


PROCEDURE

Hide 1.INSTALL HIGH VOLTAGE FUSE

CAUTION:

Wear insulated gloves.


HINT:

Perform this procedure only when replacement of the high voltage fuse is necessary.


a.
A266706E07
2.521,0.906 2.521,1.25 true 2.438,1.271 2.708,1.448 0.271,0.177 10 false *1

Remove the 2 bolts and inverter terminal cover.

Text in Illustration
*1 Interlock Connector

NOTICE:

Make sure to pull the inverter cover straight up, as a connector is connected to the bottom of the cover.



b.
A266695

Remove the 7 bolts and inverter cover.


c.
A267097E01
0.441,1.74 0.756,2.028 0.316,0.288 10 *a 0.46,2.682 0.776,2.970 0.316,0.288 10 *b

Install the high voltage fuse with the 2 bolts.

Text in Illustration
*a Correct
*b Incorrect

Torque:
5.0 N*m (51 kgf*cm, 44 in.*lbf)

NOTICE:
·

Be sure to use a torque wrench to tighten the bolts.

·

The fuse should be installed with its orientation as shown in the illustration.




d.
A266695

Temporarily install the inverter cover with the 7 bolts to prevent any foreign matter or water from entering the inverter with converter assembly.


e.
A266706E07
2.521,0.906 2.521,1.25 true 2.438,1.271 2.708,1.448 0.271,0.177 10 false *1

Temporarily install the inverter terminal cover with the 2 bolts to prevent any foreign matter or water from entering the inverter with converter assembly.

Text in Illustration
*1 Interlock Connector

NOTICE:

Make sure that the interlock connector is fully engaged.



Hide G9200 2.INSTALL INVERTER WITH CONVERTER ASSEMBLY

CAUTION:

Wear insulated gloves.


a.
A266704E02
2.688,0.177 2.885,0.552 0.198,0.375 10 false A 1.083,3.208 1.229,3.385 0.146,0.177 10 true B 2.906,2.646 3.104,2.896 0.198,0.25 10 true B

Temporarily install the inverter with converter assembly with the 3 bolts.

NOTICE:
·

Since the inverter with converter assembly is very heavy, 2 people are needed to install the inverter with converter assembly. When installing the inverter with converter assembly, do not damage the parts around it.

·

To prevent damage, do not hold the inverter with converter assembly by the connectors.

·

To prevent damage due to static electricity, do not touch the terminals of the disconnected connectors.




b.

Tighten bolt (A).

Torque:
12 N*m (122 kgf*cm, 8 ft.*lbf)


c.

Tighten the 2 bolts (B).

Torque:
12 N*m (122 kgf*cm, 8 ft.*lbf)


d.

Disconnect the No. 2 engine room wire from the protector.


Hide G90A0A 3.CONNECT NO. 1 INVERTER COOLING HOSE ASSEMBLY

a.
A266703E02
1.708,0.958 1.552,0.708 1.552,0.708 1.479,0.708 false 0.74,1.604 0.885,1.854 0.146,0.25 10 false 1 1.813,0.208 1.958,0.458 0.146,0.25 10 false 2 1.292,0.635 1.469,0.885 0.177,0.25 10 true *1

Connect the No. 1 inverter cooling hose assembly to the inverter with converter assembly and lock the hose with the retainer.

Text in Illustration
*1 Retainer

NOTICE:
·

Insert the retainer until a click sound is heard.

·

Pull on the hose to confirm that the hose is securely connected.

·

If there is foreign matter on the union or the O-ring, clean it with water and finger scouring.

·

To prevent foreign matter from entering the cooling system, do not remove the pieces of cloth or plastic bags from the pipe and disconnected hose until installation.




Hide G90B0 4.CONNECT NO. 2 INVERTER COOLING HOSE ASSEMBLY

a.
A266701E01
2.246,1.95 2.359,2.112 0.112,0.162 10 1 1.617,0.816 1.730,0.978 0.112,0.162 10 2 1.308,1.017 1.502,1.179 0.194,0.162 10 *1 1.654,1.248 1.564,1.102 1.564,1.102 1.491,1.102 false

Connect the No. 2 inverter cooling hose assembly to the inverter with converter assembly and lock the hose with the retainer.

Text in Illustration
*1 Retainer

NOTICE:
·

Insert the retainer until a click sound is heard.

·

Pull on the hose to confirm that the hose is securely connected.

·

If there is foreign matter on the union or the O-ring, clean it with water and finger scouring.

·

To prevent foreign matter from entering the cooling system, do not remove the pieces of cloth or plastic bags from the pipe and disconnected hose until installation.




Hide 82164 5.CONNECT FRAME WIRE

a.

Install the No. 2 engine room wire with the nut.

Torque:
8.4 N*m (86 kgf*cm, 74 in.*lbf)


b.

Install the No. 1 relay block cover with the 2 claws.


c.

Connect the connector.


d.

Install the relay block cover.


Hide G9223 6.REMOVE INVERTER TERMINAL COVER

CAUTION:

Wear insulated gloves.


a.
A266706E07
2.521,0.906 2.521,1.25 true 2.438,1.271 2.708,1.448 0.271,0.177 10 false *1

Remove the 2 bolts and inverter terminal cover.

Text in Illustration
*1 Interlock Connector

NOTICE:

Make sure to pull the inverter cover straight up, as a connector is connected to the bottom of the cover.



Hide G9221 7.REMOVE INVERTER COVER

CAUTION:

Wear insulated gloves.


a.
A266695

Remove the 7 bolts and inverter cover.


Hide 82122 8.CONNECT NO. 2 ENGINE WIRE

CAUTION:

Wear insulated gloves.


NOTICE:

Do not allow any foreign matter or water to enter the inverter with converter assembly.


a.
A266694E04
2.552,0.927 2.76,1.104 0.208,0.177 10 true C 0.906,0.781 1.042,1.021 0.135,0.24 10 false A 1.208,1.271 1.344,1.438 0.135,0.167 10 true B 0.969,1.854 1.104,2.021 0.135,0.167 10 true B 0.125,1.5 0.26,1.667 0.135,0.167 10 true A

Temporarily install the No. 2 engine wire (high voltage cables of the air conditioning) with the 2 bolts (A) and 2 bolts (B) to the inverter with converter assembly.

NOTICE:

To prevent the threads from being damaged, make sure to perform this step by hand.



b.

Fully tighten the 2 bolts (A).

Torque:
9.2 N*m (94 kgf*cm, 81 in.*lbf)

NOTICE:

Be sure to use a torque wrench to tighten the bolts.



c.

Fully tighten the 2 bolts (B).

Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)

NOTICE:

Be sure to use a torque wrench to tighten the bolts.



d.

Install the bracket with the bolt (C).

Torque:
9.4 N*m (96 kgf*cm, 83 in.*lbf)


Hide G1148 9.CONNECT MOTOR CABLE

CAUTION:

Wear insulated gloves.


NOTICE:

Do not allow any foreign matter or water to enter the inverter with converter assembly.


a.

Connect the motor cable (MG2).

i.
A266693E02
0.813,1.292 1.021,1.521 0.208,0.229 10 false B 1.135,1.604 1.344,1.833 0.208,0.229 10 false B 1.542,1.781 1.75,2.01 0.208,0.229 10 true B 0.885,0.396 1.021,0.625 0.135,0.229 10 true A 2.344,1.125 2.479,1.354 0.135,0.229 10 true A

Temporarily install the high voltage cable of the motor cable (MG2) with the 5 bolts to the inverter with converter assembly.

NOTICE:

To prevent the threads from being damaged, make sure to perform this step by hand.



ii.

Fully tighten the 2 bolts (A).

Torque:
9.2 N*m (94 kgf*cm, 81 in.*lbf)

NOTICE:

Be sure to use a torque wrench to tighten the bolts.



iii.

Fully tighten the 3 bolts (B).

Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)

NOTICE:

Be sure to use a torque wrench to tighten the bolts.



iv.

Connect the harness clamp.



b.

Connect the motor cable (MG1).

i.
A266692E02
1.729,1.958 1.885,2.135 0.156,0.177 10 true B 1.198,1.844 1.354,2.021 0.156,0.177 10 true B 0.771,1.427 0.927,1.604 0.156,0.177 10 true B 1.198,0.365 1.354,0.542 0.156,0.177 10 true A 2.458,1.229 2.615,1.406 0.156,0.177 10 true A

Temporarily install the high voltage cable of the motor cable (MG1) with the 5 bolts to the inverter with converter assembly.

NOTICE:

To prevent the threads from being damaged, make sure to perform this step by hand.



ii.

Fully tighten the 2 bolts (A).

Torque:
9.2 N*m (94 kgf*cm, 81 in.*lbf)

NOTICE:

Be sure to use a torque wrench to tighten the bolts.



iii.

Fully tighten the 3 bolts (B).

Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)

NOTICE:

Be sure to use a torque wrench to tighten the bolts.




Hide 82164 10.CONNECT FRAME WIRE

CAUTION:

Wear insulated gloves.


NOTICE:

Do not allow any foreign matter or water to enter the inverter with converter assembly.


a.
A266690E02
0.781,0.802 1.469,0.802 true 2.583,0.844 2.948,0.229 2.948,0.229 3.021,0.229 true 0.906,2.521 1.031,2.677 0.125,0.156 10 true B 1.24,2.583 1.385,2.75 0.146,0.167 10 true B 1.979,1.958 2.125,2.135 0.146,0.177 10 true A 0.469,1.708 0.594,1.865 0.125,0.156 10 true A 2.083,0.115 2.25,0.281 0.167,0.167 10 false *a 3.094,0.156 3.26,0.323 0.167,0.167 10 false *1 0.594,0.719 0.76,0.896 0.167,0.177 10 false *2

Temporarily install the frame wire (high voltage cables of the hybrid battery) with the 4 bolts to the inverter with converter assembly.

Text in Illustration
*1 Interlock Connector
*2 High voltage cables of hybrid battery
*a Front view of frame wire connector

NOTICE:
·

Make sure that the interlock connector are fully engaged.

·

To prevent the threads from being damaged, make sure to perform this step by hand.




b.

Fully tighten the 2 bolts (A).

Torque:
9.2 N*m (94 kgf*cm, 81 in.*lbf)

NOTICE:

Be sure to use a torque wrench to tighten the bolts.



c.

Fully tighten the 2 bolts (B).

Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)

NOTICE:

Be sure to use a torque wrench to tighten the bolts.



d.

Connect the harness clamp.


Hide 11. CHECK HIGH VOLTAGE CABLE CONNECTION

CAUTION:

Wear insulated gloves.


NOTICE:

Do not allow any foreign matter or water to enter the inverter with converter assembly.


a.
A266709

Check that each connector and terminal is firmly installed.

NOTICE:

Make sure that the bolts are fully tightened.



Hide G9221 12.INSTALL INVERTER COVER

CAUTION:

Wear insulated gloves.


a.
A266688E02
1.094,1.156 1.219,1.375 0.125,0.219 10 true A 1.615,0.458 1.75,0.646 0.135,0.188 10 true B 2.406,0.885 2.521,1.115 0.115,0.229 10 true C 1.052,0.229 1.198,0.417 0.146,0.188 10 true C 0.688,0.656 0.823,0.844 0.135,0.188 10 true C 0.375,1.198 0.51,1.385 0.135,0.188 10 true C 1.531,1.427 1.656,1.646 0.125,0.219 10 true C

Temporarily install the inverter cover with the 7 bolts to the inverter with converter assembly.

CAUTION:

An interlock connector is installed to the inverter terminal cover. Make sure to install the inverter terminal cover after installing the inverter cover.


NOTICE:

Visually confirm that the inverter cover waterproofing rubber is securely installed before installing the inverter cover.



b.

Fully tighten the bolt (A).

Torque:
11 N*m (112 kgf*cm, 8 ft.*lbf)


c.

Fully tighten the bolt (B).

Torque:
11 N*m (112 kgf*cm, 8 ft.*lbf)


d.

Fully tighten the 5 bolts (C).

Torque:
11 N*m (112 kgf*cm, 8 ft.*lbf)


Hide G9223 13.INSTALL INVERTER TERMINAL COVER

CAUTION:

Wear insulated gloves.


a.
A266706E07
2.521,0.906 2.521,1.25 true 2.438,1.271 2.708,1.448 0.271,0.177 10 false *1

Temporarily install the inverter terminal cover with the 2 bolts to the inverter with converter assembly.

Text in Illustration
*1 Interlock Connector

CAUTION:

An interlock connector is installed to the inverter terminal cover. Make sure to install the inverter terminal cover after installing the inverter cover.


NOTICE:
·

Visually confirm that the inverter terminal cover waterproofing rubber is securely installed before installing the inverter terminal cover.

·

Make sure that the interlock connector is fully engaged.




b.

Fully tighten the bolt (A).

Torque:
11 N*m (112 kgf*cm, 8 ft.*lbf)


c.

Fully tighten the bolt (B).

Torque:
11 N*m (112 kgf*cm, 8 ft.*lbf)


Hide 82111 14.INSTALL ENGINE ROOM MAIN WIRE

CAUTION:

Wear insulated gloves.


NOTICE:

Do not allow any foreign matter or water to enter the inverter with converter assembly.


a.

Connect the clamp.


b.

Connect the engine room main wire with the 2 bolts.

Torque:
9.4 N*m (96 kgf*cm, 83 in.*lbf)


c.

Connect the hose clamp.


d.
A214645

Connect the engine wire to the engine room main wire.

NOTICE:

Make sure that the interlock is fully engaged.



e.
A266685

Connect the connector to the inverter with converter assembly and lock the connector with the lock lever.