1.INSTALL HIGH VOLTAGE FUSE
Wear insulated gloves.
Perform this procedure only when replacement of the high voltage fuse is necessary.
Remove the 2 bolts and inverter terminal cover.
| *1 | Interlock Connector |
Make sure to pull the inverter cover straight up, as a connector is connected to the bottom of the cover.
Remove the 7 bolts and inverter cover.
Install the high voltage fuse with the 2 bolts.
| *a | Correct |
| *b | Incorrect |
Be sure to use a torque wrench to tighten the bolts.
The fuse should be installed with its orientation as shown in the illustration.
Temporarily install the inverter cover with the 7 bolts to prevent any foreign matter or water from entering the inverter with converter assembly.
Temporarily install the inverter terminal cover with the 2 bolts to prevent any foreign matter or water from entering the inverter with converter assembly.
| *1 | Interlock Connector |
Make sure that the interlock connector is fully engaged.
G9200
2.INSTALL INVERTER WITH CONVERTER ASSEMBLY
Wear insulated gloves.
Temporarily install the inverter with converter assembly with the 3 bolts.
Since the inverter with converter assembly is very heavy, 2 people are needed to install the inverter with converter assembly. When installing the inverter with converter assembly, do not damage the parts around it.
To prevent damage, do not hold the inverter with converter assembly by the connectors.
To prevent damage due to static electricity, do not touch the terminals of the disconnected connectors.
Tighten bolt (A).
Tighten the 2 bolts (B).
Disconnect the No. 2 engine room wire from the protector.
G90A0A
3.CONNECT NO. 1 INVERTER COOLING HOSE ASSEMBLY
Connect the No. 1 inverter cooling hose assembly to the inverter with converter assembly and lock the hose with the retainer.
| *1 | Retainer |
Insert the retainer until a click sound is heard.
Pull on the hose to confirm that the hose is securely connected.
If there is foreign matter on the union or the O-ring, clean it with water and finger scouring.
To prevent foreign matter from entering the cooling system, do not remove the pieces of cloth or plastic bags from the pipe and disconnected hose until installation.
G90B0
4.CONNECT NO. 2 INVERTER COOLING HOSE ASSEMBLY
Connect the No. 2 inverter cooling hose assembly to the inverter with converter assembly and lock the hose with the retainer.
| *1 | Retainer |
Insert the retainer until a click sound is heard.
Pull on the hose to confirm that the hose is securely connected.
If there is foreign matter on the union or the O-ring, clean it with water and finger scouring.
To prevent foreign matter from entering the cooling system, do not remove the pieces of cloth or plastic bags from the pipe and disconnected hose until installation.
82164
5.CONNECT FRAME WIRE
Install the No. 2 engine room wire with the nut.
Install the No. 1 relay block cover with the 2 claws.
Connect the connector.
Install the relay block cover.
G9223
6.REMOVE INVERTER TERMINAL COVER
Wear insulated gloves.
Remove the 2 bolts and inverter terminal cover.
| *1 | Interlock Connector |
Make sure to pull the inverter cover straight up, as a connector is connected to the bottom of the cover.
G9221
7.REMOVE INVERTER COVER
Wear insulated gloves.
Remove the 7 bolts and inverter cover.
82122
8.CONNECT NO. 2 ENGINE WIRE
Wear insulated gloves.
Do not allow any foreign matter or water to enter the inverter with converter assembly.
Temporarily install the No. 2 engine wire (high voltage cables of the air conditioning) with the 2 bolts (A) and 2 bolts (B) to the inverter with converter assembly.
To prevent the threads from being damaged, make sure to perform this step by hand.
Fully tighten the 2 bolts (A).
Be sure to use a torque wrench to tighten the bolts.
Fully tighten the 2 bolts (B).
Be sure to use a torque wrench to tighten the bolts.
Install the bracket with the bolt (C).
G1148
9.CONNECT MOTOR CABLE
Wear insulated gloves.
Do not allow any foreign matter or water to enter the inverter with converter assembly.
Connect the motor cable (MG2).
Temporarily install the high voltage cable of the motor cable (MG2) with the 5 bolts to the inverter with converter assembly.
To prevent the threads from being damaged, make sure to perform this step by hand.
Fully tighten the 2 bolts (A).
Be sure to use a torque wrench to tighten the bolts.
Fully tighten the 3 bolts (B).
Be sure to use a torque wrench to tighten the bolts.
Connect the harness clamp.
Connect the motor cable (MG1).
Temporarily install the high voltage cable of the motor cable (MG1) with the 5 bolts to the inverter with converter assembly.
To prevent the threads from being damaged, make sure to perform this step by hand.
Fully tighten the 2 bolts (A).
Be sure to use a torque wrench to tighten the bolts.
Fully tighten the 3 bolts (B).
Be sure to use a torque wrench to tighten the bolts.
82164
10.CONNECT FRAME WIRE
Wear insulated gloves.
Do not allow any foreign matter or water to enter the inverter with converter assembly.
Temporarily install the frame wire (high voltage cables of the hybrid battery) with the 4 bolts to the inverter with converter assembly.
| *1 | Interlock Connector |
| *2 | High voltage cables of hybrid battery |
| *a | Front view of frame wire connector |
Make sure that the interlock connector are fully engaged.
To prevent the threads from being damaged, make sure to perform this step by hand.
Fully tighten the 2 bolts (A).
Be sure to use a torque wrench to tighten the bolts.
Fully tighten the 2 bolts (B).
Be sure to use a torque wrench to tighten the bolts.
Connect the harness clamp.
11. CHECK HIGH VOLTAGE CABLE CONNECTION
Wear insulated gloves.
Do not allow any foreign matter or water to enter the inverter with converter assembly.
Check that each connector and terminal is firmly installed.
Make sure that the bolts are fully tightened.
G9221
12.INSTALL INVERTER COVER
Wear insulated gloves.
Temporarily install the inverter cover with the 7 bolts to the inverter with converter assembly.
An interlock connector is installed to the inverter terminal cover. Make sure to install the inverter terminal cover after installing the inverter cover.
Visually confirm that the inverter cover waterproofing rubber is securely installed before installing the inverter cover.
Fully tighten the bolt (A).
Fully tighten the bolt (B).
Fully tighten the 5 bolts (C).
G9223
13.INSTALL INVERTER TERMINAL COVER
Wear insulated gloves.
Temporarily install the inverter terminal cover with the 2 bolts to the inverter with converter assembly.
| *1 | Interlock Connector |
An interlock connector is installed to the inverter terminal cover. Make sure to install the inverter terminal cover after installing the inverter cover.
Visually confirm that the inverter terminal cover waterproofing rubber is securely installed before installing the inverter terminal cover.
Make sure that the interlock connector is fully engaged.
Fully tighten the bolt (A).
Fully tighten the bolt (B).
82111
14.INSTALL ENGINE ROOM MAIN WIRE
Wear insulated gloves.
Do not allow any foreign matter or water to enter the inverter with converter assembly.
Connect the clamp.
Connect the engine room main wire with the 2 bolts.
Connect the hose clamp.
Connect the engine wire to the engine room main wire.
Make sure that the interlock is fully engaged.
Connect the connector to the inverter with converter assembly and lock the connector with the lock lever.
G3834
15.INSTALL SERVICE PLUG GRIP
16.ADD COOLANT (for Inverter)
17.INSPECT FOR COOLANT LEAK (for Inverter)