G3834
1.INSTALL SERVICE PLUG GRIP
Wear insulating gloves.
Before connecting the service plug, check that no parts and tools remain and that the high voltage terminals and connectors are connected securely.
Wear insulated gloves and install the service plug grip in the order shown in the illustration.
Rotate the handle of the service plug grip 90° toward the battery and slide it in the direction shown by the arrow until a click sound is heard.
58167H
2.INSTALL FRONT CENTER FLOOR COVER
58166B
3.INSTALL FRONT FLOOR COVER LH
4.CONNECT CABLE TO NEGATIVE AUXILIARY BATTERY TERMINAL
When disconnecting the cable, some systems need to be initialized after the cable is reconnected (See page General>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION).
58165F
5.INSTALL FRONT FLOOR COVER RH