Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › POWER MODULE INTELLIGENT TRANSISTOR
RM2170E _51 Engine / Hybrid System _057004 HYBRID / BATTERY CONTROL _0277941 POWER MODULE INTELLIGENT TRANSISTOR A

HYBRID / BATTERY CONTROL  POWER MODULE INTELLIGENT TRANSISTOR  DISASSEMBLY  


CAUTION / NOTICE / HINT

NOTICE:
A309734

If metal shavings are created when bolts are removed from the inverter with converter assembly, remove them using tape or equivalent.


HINT:

Prepare 2 tubes of thermal grease X-23-7884-4 when replacing the power module intelligent transistor kit.

·

For Europe : 08887-83080

·

For except Europe : 08887-02809



PROCEDURE

Hide G9200 1.REMOVE INVERTER WITH CONVERTER ASSEMBLY

Hide 2.DRAIN COOLANT (for Inverter)

CAUTION:

Wear insulating gloves.


a.
A359763E02
0.823,3.001 1.095,3.182 0.272,0.181 10 *1 3.116,0.26 3.389,0.441 0.272,0.181 10 *1 3.027,2.555 3.212,2.736 0.186,0.181 10 *1 2.973,0.493 3.117,0.349 false 1.313,2.442 0.933,2.961 false 2.371,2.083 2.985,2.613 2.985,2.613 1.9,2.51 false

Apply protective tape to the areas shown in the illustration without leaving any gaps between the tape and part.

Text in Illustration
*1 Protective Tape

NOTICE:

Use non-residue type tape.



b.
A359764E01
0.244,2.589 0.490,2.835 0.246,0.246 12 *1

Tilt the inverter with converter assembly back and forth to drain the coolant (for inverter).

Text in Illustration
*1 Coolant (for inverter) Passage

NOTICE:

Do not hold the inverter with converter assembly by the coolant pipes or inverter signal connector.


HINT:

The coolant (for inverter) passage is designed as shown in the illustration. Tilt the inverter with converter assembly back and forth repeatedly to drain the coolant (for inverter) completely.



c.
A359765

Blow compressed air into the inverter with converter assembly until most all of the coolant (for inverter) is blown out.

NOTICE:

Do not damage the coolant pipes.


HINT:
·

Use a piece of cloth as shown in the illustration to prevent the coolant (for inverter) from spraying.

·

Cover the air inlet port with a piece of cloth to minimize air leakage.




Hide G9200 3.CLEAN INVERTER WITH CONVERTER ASSEMBLY

CAUTION:

Wear insulating gloves.


a.

Using a piece of cloth, clean the outside of the inverter with converter assembly and around the bolts.

NOTICE:

To prevent foreign matter from entering the inverter with converter assembly, make sure that the protective tape is not partially removed.



b.

Turn the inverter with converter assembly over and clean around the bolts.

NOTICE:

Do not hold the inverter with converter assembly by the coolant pipes.



Hide G9223 4.REMOVE INVERTER TERMINAL COVER

CAUTION:

Wear insulated gloves.


a.
A359766E01
2.679,0.675 2.91,0.941 false 2.949,0.88 3.195,1.126 0.246,0.246 12 *1

Remove the 2 bolts and inverter terminal cover.

Text in Illustration
*1 Interlock Connector

CAUTION:

An interlock connector is installed to the inverter terminal cover. Make sure to remove the inverter terminal cover before removing the inverter cover.


NOTICE:

Make sure to pull the inverter terminal cover straight up, as a connector is connected to the bottom of the cover.



Hide G9221 5.REMOVE INVERTER COVER

CAUTION:

Wear insulating gloves.


a.
A359767

Remove the 7 bolts and inverter cover.

CAUTION:

An interlock connector is installed to the inverter terminal cover. Make sure to remove the inverter terminal cover before removing the inverter cover.



Hide 6.REMOVE INVERTER SIGNAL CONNECTOR COVER

CAUTION:

Wear insulating gloves.


a.
A359768E02
2.365,0.719 2.865,0.24 false 0.792,0.521 0.323,0.375 false 2.948,1.74 2.271,1.385 false 2.927,0.156 3.177,0.406 0.25,0.25 12 false *1 0.104,0.25 0.354,0.5 0.25,0.25 12 false *1 3.01,1.667 3.26,1.917 0.25,0.25 12 false *1

Apply protective tape to the area that was exposed when the inverter terminal cover was removed.

Text in Illustration
*1 Protective Tape

NOTICE:

Use non-residue type tape.



b.
A359769E02
2.823,0.792 3.094,0.917 false 3.115,0.854 3.385,1.031 0.271,0.177 10 false *1

Remove the protective tape from the inverter signal connector.

Text in Illustration
*1 Protective Tape


c.
A359770E01
0.336,0.133 0.497,0.314 0.161,0.181 10 *1 0.566,0.238 0.895,0.703 false

Remove the 4 bolts and inverter signal connector cover.

Text in Illustration
*1 Inverter Signal Connector Cover

HINT:

As there will be dust and dirt around the inverter signal connector cover gasket, before removing the inverter signal connector cover, clean the area around the inverter signal connector cover with a piece of cloth to prevent foreign matter from entering the inverter with converter assembly.



Hide 7.REMOVE NO. 1 AND NO. 2 INVERTER DRAIN PLUG

CAUTION:
·

Wear insulating gloves.

·

Wear protective goggles.



a.
A359771E01
2.061,2.447 2.181,2.985 false 2.181,2.985 2.353,2.985 false 2.388,2.9 2.618,3.120 0.230,0.221 10 *2 2.628,3.474 2.901,3.656 0.272,0.181 10 *1 1.882,3.721 2.606,3.566 false 0.757,2.35 0.597,2.708 false 0.597,2.708 0.368,2.708 false 0.171,2.616 0.401,2.837 0.230,0.221 10 *1 1.555,0.252 1.827,0.433 0.272,0.181 10 *2 2.629,0.527 1.756,0.351 false

Using a screwdriver with its tip wrapped with protective tape, remove the No. 1 and No. 2 inverter drain plugs.

Text in Illustration
*1 No. 1 Inverter Drain Plug
*2 No. 2 Inverter Drain Plug

NOTICE:
·

Do not damage the sealing surfaces of the inverter with converter assembly.

·

Do not touch or allow grease or oil to contact the sealing surfaces of the inverter case with condenser.




Hide 8. VERIFY THAT VOLTAGE OF INVERTER WITH CONVERTER IS 0 V

CAUTION:

Wear insulating gloves.


NOTICE:

Do not allow any foreign matter or water to enter the inverter with converter assembly.


a.

Using a voltmeter, measure the voltage between the high voltage cable connector terminals.

A359772

Standard voltage:

0V


HINT:

Use measuring range of DC 750 V or more on the voltmeter.



Hide 9.REMOVE INVERTER UNION GROMMET

a.
A359773E02
1.281,1.906 1.146,1.99 1.146,1.99 0.958,1.99 false 1.646,1.813 1.708,2.052 1.708,2.052 1.792,2.052 false 0.771,1.906 1.042,2.083 0.271,0.177 10 false *2 1.823,1.958 2.094,2.135 0.271,0.177 10 false *1

Using a screwdriver with its tip wrapped with protective tape, remove the 2 inverter union grommets from the inverter with converter assembly.

Text in Illustration
*1 Inverter Union Grommet
*2 Coolant Pipe

NOTICE:

Pull the grommet straight out without applying any force to the coolant pipes.



Hide 10.REMOVE INVERTER CASE WITH CONDENSER

a.
A359774

Disengage the 2 claws and open the terminal cover.


b.
A359775

Loosen the nut of the No. 2 engine room wire to secure enough space to perform work.


c.
A359776

Remove the 5 bolts.

NOTICE:

Do not touch the bus-bars.



d.
A359777E02
2.677,1.625 2.938,1.917 2.938,1.917 3.115,1.917 false 1.104,1.49 0.813,1.875 0.813,1.875 0.625,1.875 false 3.156,1.833 3.375,2.073 0.219,0.24 10 false *1 0.438,1.792 0.76,2.031 0.323,0.24 10 false *1

Apply protective tape to the installation holes of the No. 1 and No. 2 inverter drain plugs as shown in the illustration.

Text in Illustration
*1 Protective Tape

NOTICE:
·

Use non-residue type tape.

·

Do not touch or allow grease or oil to contact the sealing surfaces of the inverter case with condenser.




e.
A359778

Remove the 11 bolts.


f.

Apply protective tape to the coolant pipe as shown in the illustration.

A359779E02
0.729,3.229 0.938,2.177 0.938,2.177 1.083,2.177 false 6.198,0.781 5.208,0.365 5.208,0.365 4.792,0.365 false 6.427,0.927 6.677,1.427 false 1.104,3.448 0.76,4.385 0.76,4.385 0.563,4.385 false 1.167,2.094 1.417,2.313 0.25,0.219 10 false *1 4.594,0.292 4.844,0.51 0.25,0.219 10 false *2 6.667,1.458 6.917,1.677 0.25,0.219 10 false *1 0.354,4.302 0.604,4.521 0.25,0.219 10 false *2

Text in Illustration
*1 Protective Tape *2 Coolant Pipe

NOTICE:
·

Do not apply excessive force to the coolant pipe.

·

Do not damage the coolant pipe.

·

Use non-residue type tape.




g.

Install SST to the inverter with converter assembly. (Step A)

SST
09891-47020  

i.
A334853E01
2.054,1.278 2.48,0.708 false 2.48,0.708 2.942,0.708 false 2.499,1.491 2.798,1.192 false 2.798,1.192 2.992,1.192 false 3.033,0.613 3.246,0.823 0.213,0.210 10 *1 3.05,1.103 3.263,1.313 0.213,0.210 10 *2

Apply protective tape to SST as shown in the illustration.

Text in Illustration
*1 SST
*2 Protective Tape


ii.

Insert SST into the inverter union grommet installation hole and tighten the bolt (A) of SST to install SST to the inverter with converter assembly as shown in the illustration.

A359780E02
0.84,0.668 1.056,0.880 0.216,0.211 10 A 0.798,1.719 1.014,1.931 0.216,0.211 10 *1 5.057,0.285 5.273,0.497 0.216,0.211 10 *1 5.005,1.577 5.221,1.788 0.216,0.211 10 *1 5.821,0.272 6.037,0.483 0.216,0.211 10 *2 5.896,1.253 6.112,1.464 0.216,0.211 10 *3 5.863,0.902 6.079,1.114 0.216,0.211 10 *a 5.667,0.667 5.828,0.977 false 5.828,0.977 5.635,1.287 false 5.518,0.412 5.674,0.332 false 5.674,0.332 5.776,0.332 false 5.734,1.481 5.785,1.314 false 5.779,1.314 5.853,1.314 false 4.595,0.568 4.709,0.365 false 4.709,0.365 5.01,0.365 false 4.583,1.432 4.721,1.64 false 4.721,1.64 4.968,1.64 false 2.229,1.611 1.298,0.724 false 1.298,0.724 0.999,0.724 false 1.883,2.128 1.228,1.785 false 1.228,1.785 0.971,1.785 false

Text in Illustration
*1 SST *2 Inverter Case with Condenser
*3 Hybrid Vehicle Converter Kit - -
*a Tip - -

NOTICE:
·

Do not damage the grommet sealing surface of the inverter with converter assembly.

·

Do not apply excessive force to the coolant pipe.




iii.

Check that the tips of SST are not in contact with the grommet sealing surface of the inverter with converter assembly.



h.

While supporting SST by hand, tighten the bolt A of SST to separate the inverter case with condenser and hybrid vehicle converter kit as shown in the illustration. (Step B)

A359868E01
0.705,0.594 0.911,0.801 0.207,0.207 10 A 0.648,1.654 0.855,1.861 0.207,0.207 10 *1 2.205,1.625 1.198,0.657 false 1.198,0.657 0.873,0.657 false 1.888,2.058 1.262,1.707 false 1.262,1.708 0.848,1.708 false

Text in Illustration
*1 SST - -

NOTICE:

Do not use air tools.



i.

Remove SST from the inverter with converter assembly, and then insert SST into the inverter union grommet installation hole on the opposite side of the inverter with converter assembly and tighten the bolt (A) of SST to install SST to the inverter with converter assembly as shown in the illustration. (Step C)

A359781E03
2.219,1.625 1.375,0.729 1.375,0.729 0.979,0.729 false 1.063,1.708 1.427,1.708 1.427,1.708 1.854,2.104 false 4.594,0.573 4.76,0.365 4.76,0.365 4.99,0.365 false 4.948,1.635 4.708,1.635 4.708,1.635 4.563,1.448 false 5.688,1.49 5.729,1.344 5.729,1.344 5.844,1.344 false 5.625,1.313 5.792,0.969 5.792,0.969 5.635,0.677 false 5.51,0.427 5.625,0.323 5.625,0.323 5.771,0.323 false 0.813,0.646 0.969,0.844 0.156,0.198 10 false A 0.875,1.615 1.125,1.833 0.25,0.219 10 false *1 5.042,0.292 5.292,0.51 0.25,0.219 10 false *1 4.99,1.552 5.24,1.771 0.25,0.219 10 false *1 5.792,0.24 6.042,0.458 0.25,0.219 10 false *2 5.823,0.875 6.073,1.094 0.25,0.219 10 false *a 5.854,1.26 6.104,1.479 0.25,0.219 10 false *3

Text in Illustration
*1 SST *2 Inverter Case with Condenser
*3 Hybrid Vehicle Converter Kit - -
*a Tips - -


j.

While supporting SST by hand, tighten the bolt A of SST to separate the inverter case with condenser and hybrid vehicle converter kit as shown in the illustration. (Step D)

A360149E02
2.219,1.677 1.344,0.698 1.344,0.698 0.969,0.698 false 1,1.667 1.344,1.667 1.344,1.667 1.865,2.135 false 0.823,0.604 2.031,0.906 1.208,0.302 10 false A 0.802,1.583 2.01,1.885 1.208,0.302 10 false *1

Text in Illustration
*1 SST - -

NOTICE:

Do not use air tools.



k.

Perform steps A, B, C and D on the opposite side of the inverter with converter assembly and remove the inverter case with condenser from the hybrid vehicle converter kit.


l.
A359867

Place the inverter case with condenser on a clean piece of cloth.

NOTICE:
·

Do not touch the bus-bars.

·

Do not touch or allow grease or oil to contact the sealing surfaces of the inverter case with condenser.




Hide 11.HOW TO PREVENT STATIC ELECTRICITY

SST
09890-47010  

NOTICE:
·

Static electricity should be eliminated when removing/installing the inverter with converter assembly.

·

Do not touch the electronic components of a circuit board.

·

Keep clothes away from electronic components.

·

Place parts removed from the inverter with converter assembly on an antistatic mat.



a.
E104190

Wear an antistatic wrist strap.


b.

Connect the ground clip of the antistatic mat securely to a ground point provided in the workshop or on a workbench (anchor bolt).

HINT:

If the ground clip cable is too short, use an extension cable.



c.

Connect the ground clip of the antistatic wrist strap securely to the specified point of the antistatic mat.


d.

After removing the inverter case with condenser, perform work with bare hands to prevent damage from static electricity and entry of foreign matter.


Hide 12.REMOVE INVERTER TERMINAL WITH SENSOR SUB-ASSEMBLY

NOTICE:
·

If metal shavings are created, remove them using tape or equivalent.

·

Do not touch the circuit board.

·

Do not allow any moisture to come into contact with the inverter terminal with sensor sub-assembly.

·

Do not touch or allow grease or oil to contact the sealing surfaces of the inverter case with condenser.



a.
A361152

Disconnect the 3 connectors from the MG control computer with bracket sub-assembly.

NOTICE:

Do not move a pen sheet out of position when disconnecting the connectors.


HINT:
·

If the pen sheet is moved out of position, return it to its original position when connecting the connectors




b.
A361153

Remove the 6 bolts.

NOTICE:

Do not touch the bus-bars.



c.
A361154

Remove the 4 bolts and inverter terminal with sensor sub-assembly.


Hide 13.REMOVE MG CONTROL COMPUTER WITH BRACKET SUB-ASSEMBLY

NOTICE:
·

If metal shavings are created, remove them using tape or equivalent.

·

Do not touch the circuit board.

·

Do not allow any moisture to come into contact with the MG control computer with bracket sub-assembly.



a.
A361155E02
0.234,2.308 0.506,2.489 0.272,0.181 10 *a 1.675,1.305 0.615,2.426 0.615,2.426 0.432,2.426 false

While disengaging the white resin lock claws of the connector, disconnect the flat cable from the power module intelligent transistor kit.

Text in Illustration
*a Do not disconnect

NOTICE:
·

Do not disconnect the flat cable from the MG control computer with bracket sub-assembly.

·

Do not use any tools.




b.
A361156

Disconnect the 2 connectors.

NOTICE:

Do not move a pen sheet out of position when disconnecting the connectors.



c.
A361159

Disconnect the connector.


d.

Disengage the 2 wire harnesses from the 4 clamps.

A361157


e.
A361158

Remove the 4 bolts and MG control computer with bracket sub-assembly.


Hide 14.REMOVE POWER MODULE INTELLIGENT TRANSISTOR KIT

NOTICE:
·

If metal shavings are created, remove them using tape or equivalent.

·

Do not touch the circuit board.

·

Do not allow any moisture to come into contact with the power module intelligent transistor kit.



a.
A359880

Remove the 3 bolts.

NOTICE:

Do not touch the bus-bars.



b.
A361160

Remove the 4 bolts.


c.
A361161

Using a screwdriver with its tip wrapped with protective tape, lift the power module intelligent transistor kit.


d.
A361162E03
2.677,0.531 2.854,0.125 2.854,0.125 2.958,0.125 false 0.563,1.594 0.302,1.854 0.302,1.854 0.365,1.854 false 0.396,1.792 0.667,1.969 0.271,0.177 10 false *1 2.979,0.052 3.156,0.229 0.177,0.177 10 false *1

While holding the base of the coolant pipes, remove the power module intelligent transistor kit.

NOTICE:

Do not touch the circuit board.


Text in Illustration
*1 Base of the coolant pipe