16031
1.INSPECT WATER INLET WITH THERMOSTAT SUB-ASSEMBLY
The valve opening temperature is inscribed on the water inlet with thermostat sub-assembly.
Immerse the water inlet with thermostat sub-assembly in water and then gradually heat the water.
Check the valve opening temperature of the water inlet with thermostat sub-assembly.
80 to 84°C (176 to 183°F)
If the valve opening temperature is not as specified, replace the water inlet with thermostat sub-assembly (See page Engine / Hybrid System>1NZ-FXE (COOLING)>THERMOSTAT>REMOVAL).
Check the valve lift.
| *a | Valve Lift |
8.0 mm (0.315 in.) or more at 95°C (203°F)
If the valve lift is not as specified, replace the water inlet with thermostat sub-assembly (See page Engine / Hybrid System>1NZ-FXE (COOLING)>THERMOSTAT>REMOVAL).
Check that the valve is fully closed when the water inlet with thermostat sub-assembly is at low temperatures (below 77°C (171°F)).
If it is not fully closed, replace the water inlet with thermostat sub-assembly (See page Engine / Hybrid System>1NZ-FXE (COOLING)>THERMOSTAT>REMOVAL).