Home › Engine / Hybrid System › 1NZ-FXE (COOLING) › THERMOSTAT
RM2170E _51 Engine / Hybrid System _057009 1NZ-FXE COOLING _0277975 THERMOSTAT A

1NZ-FXE COOLING  THERMOSTAT  REMOVAL  


PROCEDURE

Hide 17705 2.REMOVE AIR CLEANER CAP SUB-ASSEMBLY

Hide 16031 5.REMOVE WATER INLET WITH THERMOSTAT SUB-ASSEMBLY

a.
A267958E06
0.438,1.74 0.656,1.74 0.656,1.74 0.979,1.354 false 2.177,0.896 2.302,0.896 2.302,0.896 2.573,1.406 false 1.948,0.802 2.177,0.979 0.229,0.177 10 true *1 0.24,1.656 0.469,1.833 0.229,0.177 10 false *2

Disconnect the water inlet hose and No. 3 water by-pass hose.

Text in Illustration
*1 Water Inlet Hose
*2 No. 3 Water By-pass Hose

NOTICE:
·

Do not apply force to the water inlet with thermostat sub-assembly when disconnecting the No. 3 water by-pass hose.

·

Do not damage the water inlet with thermostat sub-assembly.




b.
A267959

Remove the 2 bolts and water inlet with thermostat sub-assembly.


c.
A267962

Remove the gasket from the water inlet with thermostat sub-assembly.