1. PRECAUTION
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notice before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).
58165F
2.REMOVE FRONT FLOOR COVER RH (for LHD)
3.DISCONNECT CABLE FROM NEGATIVE AUXILIARY BATTERY TERMINAL (for LHD)
When disconnecting the cable, some systems need to be initialized after the cable is reconnected (See page General>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION).
55405B
4.REMOVE CLUSTER INSTRUMENT CLUSTER FINISH PANEL SUB-ASSEMBLY (for LHD)
5.REMOVE POWER SWITCH (for LHD)
Disengage the 2 claws and remove the power switch.
Disconnect the power switch connector.
6.REMOVE UPPER INSTRUMENT PANEL ASSEMBLY (for RHD)
7.REMOVE POWER SWITCH (for RHD)
Disengage the 2 claws and remove the power switch.
Disconnect the power switch connector.