This circuit detects the power switch on (IG) or off condition, and sends it to the main body ECU (multiplex network body ECU).
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Check for DTCs (See page Vehicle Interior>THEFT DETERRENT / KEYLESS ENTRY>SMART ENTRY AND START SYSTEM (for Start Function)>DTC CHECK / CLEAR).
| Result | Proceed to |
|---|---|
| DTC is not output | A |
| DTC is output | B |
A
B
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Body / Main Body / Data List.
Read the Data List according to the display on the intelligent tester.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| IG SW | Power switch on (IG) signal/ON or OFF | ON: Power switch on (IG)
OFF: Power switch off |
- |
Normal conditions listed above are displayed.
OK
NG
Disconnect the 3E*1 or 3F*2 instrument panel junction block assembly connectors.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3E-1 - Body ground*1 | Power switch off | 11 to 14 V |
| 3F-1 - Body ground*2 | Power switch off | 11 to 14 V |
*1: for LHD
*2: for RHD
OK
NG
Disconnect the 3A instrument panel junction block assembly connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3A-54 - 3A-40 | Always | Below 1 Ω |
| 3A-54 - Body ground | Always | 10 kΩ or higher |
OK
NG
Remove the instrument panel junction block assembly (See page Power Source / Network>POWER DISTRIBUTION>MAIN BODY ECU>REMOVAL).
Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.
Measure the resistance according to the value(s) in the table below.
| *a | Component without harness connected
(Instrument panel junction block assembly) |
*b | for LHD |
| *c | for RHD | - | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3A-40 - MB-32 (IG) | Always | Below 1 Ω |
| 3E-1 - 3A-54*1 | Always | 10 kΩ or higher |
| 3E-1 - 3A-54*1 | Auxiliary battery positive (+) → 3A-29
Auxiliary battery negative (-) → 3B-8 |
Below 1 Ω |
| 3F-1 - 3A-54*2 | Always | 10 kΩ or higher |
| 3F-1 - 3A-54*2 | Auxiliary battery positive (+) → 3A-29
Auxiliary battery negative (-) → 3B-8 |
Below 1 Ω |
*1: for LHD
*2: for RHD
OK
NG