This circuit is the power source circuit for the meter. This circuit provides two types of power sources; one is a constant power source, and the other is an IG power source.
Inspect the fuses of circuits related to this system before performing the following inspection procedure.
Disconnect the G1 combination meter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G1-20 (ET) - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G1-21 (IG+) - Body ground | Power switch off | Below 1 V |
| Power switch on (IG) | 11 to 14 V | |
| G1-1 (B) - Body ground | Power switch off | 11 to 14 V |
| *a | Front view of wire harness connector
(to Combination Meter Assembly) |
OK
NG