DESCRIPTION

The room temperature sensor (cooler thermistor) is installed in the instrument panel to detect the cabin temperature which is used to control heater and air conditioning system AUTO mode. The resistance of the room temperature sensor (cooler thermistor) changes in accordance with the cabin temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.

The air conditioning amplifier assembly applies a voltage (5 V) the room temperature sensor (cooler thermistor) and reads voltage changes due to changes in the resistance of the room temperature sensor (cooler thermistor).

DTC No. DTC Detection Condition Trouble Area
B1411/11 Open or short in room temperature sensor (cooler thermistor) circuit
·

Room temperature sensor (cooler thermistor)

·

Harness or connector between room temperature sensor (cooler thermistor) and air conditioning amplifier assembly

·

Air conditioning amplifier assembly



WIRING DIAGRAM

E236721E93
2.147,0.469 2.244,0.643 0.097,0.174 10 1 2.147,1.42 2.244,1.594 0.097,0.174 10 2 1.963,0.469 2.075,0.643 0.113,0.174 10 + 1.994,1.42 2.076,1.594 0.082,0.174 10 - 5.117,0.472 5.290,0.647 0.173,0.174 10 29 5.119,1.425 5.290,1.599 0.172,0.174 10 34 5.419,0.56 5.622,0.734 0.203,0.174 10 TR 5.419,1.512 5.762,1.687 0.343,0.174 10 SG-1 0.833,1.802 1.154,1.977 0.321,0.174 10 G31 0.833,1.961 2.529,2.293 1.696,0.332 10 Room Temperature Sensor (Cooler Thermistor) 5.067,1.883 5.352,2.057 0.285,0.174 10 G34 5.067,2.041 6.749,2.355 1.682,0.313 10 Air Conditioning Amplifier Assembly

PROCEDURE

1.READ VALUE USING INTELLIGENT TESTER
a.

Connect the intelligent tester to the DLC3.


b.

Turn the power switch on (IG).


c.

Turn the intelligent tester on.


d.

Enter the following menus: Body / Air Conditioner / Data List.


e.

Check the value(s) by referring to the table below.

Air Conditioner
Tester Display Measurement Item/Range Normal Condition Diagnostic Note
Room Temperature Sensor Room temperature sensor (cooler thermistor) /
min.: -6.50°C (20.30°F)
max.: 57.25°C (135.05°F)
Actual cabin temperature displayed -

OK:

The display is as specified in the normal condition column.


Result:
Result Proceed to
NG A
OK (When troubleshooting according to Problem Symptoms Table) B
OK (When troubleshooting according to the DTC) C




A

2.INSPECT ROOM TEMPERATURE SENSOR (COOLER THERMISTOR)

B

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE

C

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

2.INSPECT ROOM TEMPERATURE SENSOR (COOLER THERMISTOR)
a.

Remove the room temperature sensor (cooler thermistor) (See page Vehicle Interior>HEATING / AIR CONDITIONING>ROOM TEMPERATURE SENSOR>REMOVAL).


b.

Disconnect the G31 room temperature sensor (cooler thermistor) connector.

E319151E03
1.792,0.417 2.208,0.667 0.417,0.25 2,1.677 2.51,1.323 2.51,1.323 2.646,1.323 false 4.844,1.49 5.25,0.958 5.25,0.958 5.385,0.958 false 2.031,1.073 2.427,0.906 false 1.917,1.073 1.49,0.885 false 0.469,0.26 0.781,0.458 0.313,0.198 10 false *a 2.698,1.25 3.01,1.448 0.313,0.198 10 false *b 4.052,0.271 4.365,0.469 0.313,0.198 10 false *c 5.49,0.833 5.802,1.031 0.313,0.198 10 false *d 6.75,2.49 7.063,2.688 0.313,0.198 10 false *e 4.135,2.406 4.438,2.792 0.302,0.385 10 false 10 4.104,2.563 4.427,2.781 0.323,0.219 10 false (50) 4.583,2.406 4.885,2.792 0.302,0.385 10 false 20 5.042,2.406 5.344,2.792 0.302,0.385 10 false 30 5.5,2.406 5.802,2.792 0.302,0.385 10 false 40 5.938,2.406 6.24,2.792 0.302,0.385 10 false 50 6.375,2.406 6.677,2.792 0.302,0.385 10 false 60 4.542,2.563 4.865,2.781 0.323,0.219 10 false (68) 5.01,2.563 5.333,2.781 0.323,0.219 10 false (86) 5.427,2.563 5.813,2.781 0.385,0.219 10 false (104) 5.865,2.563 6.25,2.781 0.385,0.219 10 false (122) 6.302,2.552 6.688,2.771 0.385,0.219 10 false (140) 3.958,0.521 7.156,0.917 3.198,0.396 10 false 4.0 3.958,0.74 7.156,1.135 3.198,0.396 10 false 3.5 3.958,0.958 7.156,1.354 3.198,0.396 10 false 3.0 3.958,1.177 7.156,1.573 3.198,0.396 10 false 2.5 3.958,1.396 7.156,1.792 3.198,0.396 10 false 2.0 3.958,1.635 7.156,2.031 3.198,0.396 10 false 1.5 3.958,1.854 7.156,2.25 3.198,0.396 10 false 1.0 3.958,2.271 7.156,2.667 3.198,0.396 10 false 0.0 3.958,2.063 7.156,2.458 3.198,0.396 10 false 0.5 2.5,0.802 2.813,1 0.313,0.198 10 false + 1.333,0.781 1.646,0.979 0.313,0.198 10 false - 1.865,0.458 2.333,0.698 0.469,0.24 10 false G31


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
G31-1 (+) - G31-2 (-) 10°C (50°F) 3.00 to 3.73 kΩ
G31-1 (+) - G31-2 (-) 15°C (59°F) 2.45 to 2.88 kΩ
G31-1 (+) - G31-2 (-) 20°C (68°F) 1.95 to 2.30 kΩ
G31-1 (+) - G31-2 (-) 25°C (77°F) 1.60 to 1.80 kΩ
G31-1 (+) - G31-2 (-) 30°C (86°F) 1.28 to 1.47 kΩ
G31-1 (+) - G31-2 (-) 35°C (95°F) 1.00 to 1.22 kΩ
G31-1 (+) - G31-2 (-) 40°C (104°F) 0.80 to 1.00 kΩ
G31-1 (+) - G31-2 (-) 45°C (113°F) 0.65 to 0.85 kΩ
G31-1 (+) - G31-2 (-) 50°C (122°F) 0.50 to 0.70 kΩ
G31-1 (+) - G31-2 (-) 55°C (131°F) 0.44 to 0.60 kΩ
G31-1 (+) - G31-2 (-) 60°C (140°F) 0.36 to 0.50 kΩ


NOTICE:
·

Hold the sensor only by its connector. Touching the sensor may change the resistance value.

·

When measuring, the sensor temperature must be the same as the ambient temperature.



HINT:

As the temperature increases, the resistance decreases (see the graph).


Text in Illustration
*a Component without harness connected
(Room Temperature Sensor (Cooler Thermistor))
*b Sensing Portion
*c Resistance (kΩ)
*d Allowable Range
*e Temperature (°C (°F))



OK

3.CHECK HARNESS AND CONNECTOR ( ROOM TEMPERATURE SENSOR (COOLER THERMISTOR) - AIR CONDITIONING AMPLIFIER ASSEMBLY)

NG

REPLACE ROOM TEMPERATURE SENSOR (COOLER THERMISTOR)

3.CHECK HARNESS AND CONNECTOR ( ROOM TEMPERATURE SENSOR (COOLER THERMISTOR) - AIR CONDITIONING AMPLIFIER ASSEMBLY)
a.

Disconnect the G34 air conditioning amplifier assembly connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
G34-29 (TR) - G31-1 (+) Always Below 1 Ω
G34-34 (SG-1) - G31-2 (-) Always Below 1 Ω
G34-29 (TR) - Body ground Always 10 kΩ or higher
G34-34 (SG-1) - Body ground Always 10 kΩ or higher




OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG