HEATING / AIR CONDITIONING
AIR CONDITIONING SYSTEM
- PRECAUTION2011.12–2014.122014.12–2015.11from 2015.11
- PARTS LOCATION2011.12–2014.122014.12–2017.06from 2017.06
- SYSTEM DIAGRAM2011.12–2014.122014.12–2017.06from 2017.06
- SYSTEM DESCRIPTION2011.12–2014.122014.12–2017.06from 2017.06
- HOW TO PROCEED WITH TROUBLESHOOTING2011.12–2014.12from 2014.12
- CUSTOMIZE PARAMETERS2011.12–2014.12from 2014.12
- INITIALIZATION
- PROBLEM SYMPTOMS TABLE2011.12–2013.122013.12–2014.122014.12–2017.06from 2017.06
- TERMINALS OF ECU2011.12–2014.122014.12–2017.06from 2017.06
- DIAGNOSIS SYSTEM2011.12–2014.122014.12–2017.06from 2017.06
- DTC CHECK / CLEAR
- CHECK MODE PROCEDURE2011.12–2014.122014.12–2017.06from 2017.06
- DATA LIST / ACTIVE TEST2011.12–2014.12from 2014.12
- DIAGNOSTIC TROUBLE CODE CHART2011.12–2014.122014.12–2017.06from 2017.06
- B1411/11 Open or short in room temperature sensor (cooler thermistor) circuit
- B1412/12 Open or short in ambient temperature sensor (thermistor assembly) circuit2011.12–2017.06from 2017.06
- B1413/13 Open or short in evaporator temperature sensor (No. 1 cooler thermistor) circuit
- B1423/23 · Open or short in air conditioning pressure sensor circuit · Refrigerant pressure on the high pressure side...2011.12–2014.12from 2014.12
- B1441/41 Air mix damper position sensor value does not change even though air conditioning amplifier assembly operates...2011.12–2013.122013.12–2014.12from 2014.12
- B1442/42 Air inlet damper position sensor value does not change even though air conditioning amplifier assembly...
- B1443/43 Air outlet damper position sensor value does not change even though the air conditioning amplifier assembly...2011.12–2013.122013.12–2014.12from 2014.12
- B1471/71 · Open or short in A/C inverter high voltage power resource system · The boost inverter is broken or...2011.12–2014.12from 2014.12
- B1472/72 Open or short in A/C inverter high voltage output system2011.12–2014.12from 2014.12
- B1473/73 Open or short in A/C inverter start-up signal system2011.12–2014.12from 2014.12
- B1474/74 A/C inverter malfunction2011.12–2014.12from 2014.12
- B1475/75 Temperature of the inverter is outside the specified range (temperature is too high), or there is an open or...2011.12–2014.12from 2014.12
- B1476/76 Motor rotation load while the compressor is operating is too large or too small.2011.12–2014.12from 2014.12
- B1477/77 An open or short to ground in the inverter control power voltage circuit.2011.12–2014.12from 2014.12
- B1497/97 Error or open in communication line2011.12–2013.12from 2013.12
- B1498/98 · Communication line error or open between the hybrid vehicle control ECU and compressor with motor assembly....2011.12–2014.12from 2014.12
- B14A2 Short in cooler thermistor (solar sensor) circuit2011.12–2017.06from 2017.06
- B14B2 Lost communication with the air conditioning panel (heater control switch board).2011.12–2014.12from 2014.12
- B14B8 When the following conditions is detected using the refrigerant shortage check in normal operation: The...2011.12–2014.12from 2014.12
- P0AA6-611 High voltage system insulation malfunction2011.12–2014.12from 2014.12
- U0101, U0142, U0155, U02932011.12–2014.12from 2014.12
- Blower Motor Circuit2011.12–2017.06from 2017.06
- Steering Pad Switch Circuit2011.12–2014.12from 2014.12
- ECO Switch Circuit2011.12–2014.12from 2014.12
- IG Power Source Circuit2011.12–2014.12from 2014.12
- Back-up Power Source Circuit
REFRIGERANT
REFRIGERANT LINE
AIR CONDITIONING UNIT
- COMPONENTS2011.12–2013.122013.12–2014.12from 2014.12
- REMOVAL2011.12–2014.12from 2014.12
- DISASSEMBLY2011.12–2013.12from 2013.12
- REASSEMBLY2011.12–2013.12from 2013.12
- INSTALLATION2011.12–2014.12from 2014.12
BLOWER UNIT
FRONT BLOWER MOTOR
COOLER EXPANSION VALVE
COMPRESSOR
- COMPONENTS2011.12–2017.06from 2017.06
- REMOVAL2011.12–2014.122014.12–2017.06from 2017.06
- INSTALLATION2011.12–2014.122014.12–2017.06from 2017.06
CONDENSER
- COMPONENTS2011.12–2014.122014.12–2017.062017.06–2018.08from 2018.08
- ON-VEHICLE INSPECTION
- REMOVAL2011.12–2014.122014.12–2017.062017.06–2018.08from 2018.08
- DISASSEMBLY
- REASSEMBLY
- INSTALLATION2011.12–2014.122014.12–2017.062017.06–2018.08from 2018.08
ROOM TEMPERATURE SENSOR
- COMPONENTS2011.12–2017.06from 2017.06
- REMOVAL2011.12–2014.122014.12–2017.06from 2017.06
- INSPECTION
- INSTALLATION2011.12–2017.06from 2017.06
AMBIENT TEMPERATURE SENSOR
- COMPONENTS
- REMOVAL2011.12–2014.122014.12–2018.08from 2018.08
- INSPECTION
- INSTALLATION2011.12–2014.122014.12–2018.08from 2018.08
FRONT EVAPORATOR TEMPERATURE SENSOR
- COMPONENTS2011.12–2013.12from 2013.12
- REMOVAL2011.12–2013.12from 2013.12
- INSPECTION
- INSTALLATION2011.12–2013.12from 2013.12
SOLAR SENSOR
- COMPONENTS2011.12–2017.06from 2017.06
- REMOVAL2011.12–2017.06from 2017.06
- INSPECTION2011.12–2017.06from 2017.06
- INSTALLATION2011.12–2017.06from 2017.06
AIR CONDITIONING PRESSURE SENSOR
- COMPONENTS
- ON-VEHICLE INSPECTION
- REMOVAL2011.12–2014.12from 2014.12
- INSTALLATION2011.12–2014.12from 2014.12
AIR CONDITIONING PANEL
- COMPONENTS2011.12–2014.122014.12–2017.06from 2017.06
- REMOVAL2011.12–2014.122014.12–2017.06from 2017.06
- DISASSEMBLY2011.12–2014.122014.12–2017.06from 2017.06
- REASSEMBLY2011.12–2014.122014.12–2017.06from 2017.06
- INSTALLATION2011.12–2017.06from 2017.06