| Air conditioning amplifier assembly
|
Power management control ECU
|
Heater idle up request signal
|
CAN
|
| ECO mode switch (eco switch assembly) information
|
| Engine ON request signal
|
| Charging control inhibit signal
|
| Cooling fan motor drive request signal
|
| Prior A/C control request signal
|
| Heating performance assistance request signal to transmission system
|
| Inlet state signal (for cooling battery)
|
| Stand by for inverter request signal
|
| Humidity control for compressor with motor assembly start signal
|
| Compressor with motor assembly start signal
|
| Compressor with motor assembly target revolutions signal
|
| Front blower level indicator signal
|
| In-vehicle temperature signal
|
| Ambient temperature display signal
|
| A/C control state signal
|
| Air conditioning amplifier assembly
|
Combination meter assembly
|
Ambient temperature display signal
|
CAN
|
| Driver temperature display signal
|
| Ambient temperature display 0.0°C (32°F) or 0.5°C (32.9°F) switch signal
|
| REC indicator signal
|
| FRS indicator signal
|
| Presence signal of exhaust heat withdrawal instrument
|
| Air conditioning amplifier assembly
|
Main body ECU (multiplex network body ECU)
|
Ambient temperature display signal
|
CAN
|
| A/C control state signal
|
| ECM
|
Air conditioning amplifier assembly
|
Engine rpm data
|
CAN
|
| Estimated flux of engine water pump
|
| Compulsory internal air circulation command signal at high water temperature
|
| Engine coolant temperature signal
|
| Main body ECU (multiplex network body ECU)
|
Air conditioning amplifier assembly
|
Tail light request signal
|
CAN
|
| Destination symbol
|
| Destination package 1
|
| Destination package 2
|
| Steering wheel
|
| Engine starter condition signal
|
| Light sensor illuminance data signal
|
| Defogger on request
|
| A/C on request
|
| Combination meter assembly
|
Air conditioning amplifier assembly
|
Vehicle speed signal (meter to other)
|
CAN
|
| Power management control ECU
|
Air conditioning amplifier assembly
|
Shift position P signal
|
CAN
|
| Shift position R signal
|
| Shift position N signal
|
| Shift position D signal
|
| Shift position B signal
|
| Eco mode indicator signal
|
| State of STB
|
| Compulsion recycle request
|
| Communication A/C inverter and HV ECU
|
| A/C inverter STB malfunction
|
| A/C permission electric power
|
| READY signal
|
| A/C inverter output signal
|
| A/C inverter main voltage signal
|
| Motor overload information signal
|
| Motor start information signal
|
| A/C inverter internal power source malfunction signal
|
| STB wire short signal
|
| A/C inverter temperature information signal
|
| Self check signal
|
| Thermistor cold temperature malfunction signal
|
| Compressor start flag signal
|
| A/C motor current signal
|
| A/C input power signal
|
| A/C motor current request signal
|
| A/C inverter temperature signal
|
| A/C inverter voltage signal
|
| Air conditioning panel (heater control switch board)
|
Air conditioning amplifier assembly
|
OFF switch operation signal
|
LIN
|
| Blower switch operation signal (up, down)
|
| MODE switch operation signal
|
| DEF switch operation signal
|
| RDEF switch operation signal
|
| REC/FRS switch operation signal
|
| A/C switch operation signal
|
| Set temperature switch operation signal
|
| Air conditioning amplifier assembly
|
Air conditioning panel (heater control switch board)
|
Entire front panel display instruction signal
|
LIN
|
| Blower level display instruction signal
|
| A/C display instruction signal
|
| Rec display instruction signal
|
| Air outlet display instruction signal
|
| RDEF display instruction signal
|
| Set temperature display instruction signal
|