DATA LIST
Using the intelligent tester to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Body / Air Conditioner / Data List.
Check the value(s) by referring to the table below.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Room Temperature Sensor | Room temperature sensor (cooler thermistor) /
Min.: -6.50°C (20.30°F) Max.: 57.25°C (135.05°F) |
Actual cabin temperature displayed | - |
| Ambient Temp Sensor | Ambient temperature sensor (thermistor assembly) /
Min.: -23.30°C (-9.94°F) Max.: 65.95°C (150.71°F) |
Actual ambient temperature displayed | - |
| Adjusted Ambient Temp | Adjusted ambient temperature /
Min.: -30.80°C (-23.44°F) Max.: 50.80°C (123.44°F) |
- | - |
| Evaporator Fin Thermistor | Evaporator temperature sensor (No. 1 cooler thermistor) /
Min.: -29.70°C (-21.46°F) Max.: 59.55°C (139.19°F) |
Actual evaporator temperature displayed | - |
| Evaporator Target Temp | Evaporator target temperature /
Min.: -327.68°C (-557.82°F) Max.: 327.67°C (621.81°F) |
Evaporator target temperature displayed | - |
| Solar Sensor (D Side) | Solar sensor /
Min.: 0 Max.: 255 |
Solar sensor value increases as brightness increases | - |
| Engine Coolant Temp | Engine coolant temperature sensor /
Min.: 1.30°C (34.34°F) Max.: 90.55°C (194.99°F) |
Actual engine coolant temperature displayed | - |
| Set Temperature (D Side) | Set temperature /
Min.: MAX COLD Max.: MAX HOT |
Set temperature displayed | - |
| Blower Motor Speed Level | Blower motor speed level /
Min.: 0 Max.: 31 |
Displayed speed level increases in range between 0 and 31 as blower motor speed increases | - |
| Regulator Pressure Sensor | Air conditioning pressure sensor /
Min.: -0.4566 MPaG Max.: 3.2943 MPaG |
Actual pressure displayed | - |
| Air Mix Servo Targ Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (air mix) target pulse /
Min.: 128 Max.: 383 |
MAX. COLD: 257 (pulse)
MAX. HOT: 173 (pulse) |
- |
| Air Mix Servo Actual Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (air mix) actual pulse /
Min.: 128 Max.: 383 |
MAX. COLD: 257 (pulse)
MAX. HOT: 173 (pulse) |
- |
| Air Outlet Servo Pulse (D) | No. 2 air conditioning radiator damper servo sub-assembly (air outlet) target pulse /
Min.: 128 Max.: 383 |
FACE: 267 (pulse)
B/L: 250 (pulse) FOOT: 227 (pulse) FOOT/DEF: 220 (pulse) DEF: 206 (pulse) |
- |
| Air Outlet Servo Actu Pulse(D) | No. 2 air conditioning radiator damper servo sub-assembly (air outlet) actual pulse /
Min.: 128 Max.: 383 |
FACE: 267 (pulse)
B/L: 250 (pulse) FOOT: 227 (pulse) FOOT/DEF: 220 (pulse) DEF: 206 (pulse) |
- |
| Air Inlet Damper Targ Pulse | No. 1 blower damper servo sub-assembly (air inlet) target pulse /
Min.: 128 Max.: 383 |
RECIRCULATION: 287 (pulse)
FRESH: 254 (pulse) |
- |
| Air Inlet Damper Actual Pulse | No. 1 blower damper servo sub-assembly (air inlet) actual pulse /
Min.: 128 Max.: 383 |
RECIRCULATION: 287 (pulse)
FRESH: 254 (pulse) |
- |
| Compressor Speed | Compressor speed /
Min.: 0 rpm Max.: 65535 rpm |
Actual compressor rotation speed displayed | - |
| Compressor Target Speed | Compressor target speed /
Min.: 0 rpm Max.: 65535 rpm |
Compressor target rotation speed displayed | - |
| Shift Set Temperature | Shift set temperature /
2C decr, 1C decr, Normal, 1C incr, 2C incr |
Customized value displayed | - |
| Air Inlet Mode | Air inlet mode /
Auto or Manual |
Customized value displayed | - |
| Noise and Vibration Reduction | Noise and vibration reduction /
OFF or ON |
Customized value displayed | - |
| ECO MODE Cancel | ECO MODE Cancel /
OFF or ON |
Customized value displayed | - |
| ECO Switch | ECO mode switch (eco switch assembly) /
OFF or ON |
ECO mode switch (eco switch assembly) not operated: OFF
(when switch is not pressed) |
- |
| ECO mode switch (eco switch assembly) operated: ON
(when switch is pressed) |
- | ||
| Refrigerant Shortage Check | Refrigerant shortage check /
ON or OFF |
Customized value displayed | - |
| Fan speed increment control | Fan speed increment control /
Slow, Normal, Fast |
Customized value displayed | - |
| Foot/DEF Auto Mode | Foot/DEF Auto Mode /
ON or OFF |
Customized value displayed | - |
| Foot/DEF Auto Blow Up | Foot/DEF Auto blower speed increase /
ON or OFF |
Customized value displayed | - |
| Ambient Temperature Shift | Ambient temperature shift /
3C decr, 2C decr, 1C decr, Normal, 1C incr, 2C incr, 3C incr |
Customized value displayed | - |
| Pls Servo Test Sts | Pulse servo motor test status/
Wait, Move, Comp, Error, Stop |
Pulse servo motor test status | - |
| Compressor Drive Check | Compressor drive check /
OK or NG |
NG: Compressor does not drive
OK: Compressor drives |
- |
| Number of Trouble Codes | Number of trouble codes /
Min.: 0 Max.: 255 |
Number of DTCs displayed | - |
ACTIVE TEST
Using the intelligent tester to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Body / Air Conditioner / Active Test.
Check the operation by referring to the table below.
| Tester Display | Test Part | Control Range | Diagnostic Note |
|---|---|---|---|
| Blower Motor | Blower motor with fan sub-assembly | Min.: 0, Max.: 31 | - |
| Compressor Target Speed | Compressor with motor assembly | Min.: 0, Max.: 7500 | - |
| Defogger Relay (Rear) | Defogger relay | OFF, ON | - |
| Water Pump | Engine water pump assembly | OFF, ON | - |
| Electrical Fan | Electrical fan | OFF, ON | - |
| Air Mix Servo Targ Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (air mix) pulse | Min.: 128, Max.: 383 | Operates between 173 and 257 pulses |
| Air Outlet Servo Pulse (D) | No. 2 air conditioning radiator damper servo sub-assembly (air outlet) pulse | Min.: 128, Max.: 383 | Operates between 206 and 267 pulses |
| Air Inlet Damper Targ Pulse | No. 1 blower damper servo sub-assembly (air inlet) target pulse | Min.: 128, Max.: 383 | Operates between 254 and 287 pulses |