1.CUSTOMIZE AIR CONDITIONING SYSTEM
Customizing with the intelligent tester
The following items can be customized.
When the customer requests a change in a function, first make sure that the function can be customized.
Be sure to make a note of the current settings before customizing.
When troubleshooting a function, first make sure that the function is set to the default setting.
Connect the intelligent tester.
Turn the power switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Body / Air Conditioner / Utility / Customize.
Select the setting by referring to the table below.
| Tester Display | Default | Content | Setting | Relevant ECU |
|---|---|---|---|---|
| Set Temperature Shift | Normal | Function to perform control with the shifted temperature versus the displayed temperature | -2C, -1C, Normal, +1C, +2C | Air Conditioning Amplifier Assembly |
| Air Inlet Mode | Automatic | In case of turning the A/C on to cool the cabin down quickly, this is the function to change the mode automatically to RECIRCULATION mode | Automatic or Manual | Air Conditioning Amplifier Assembly |
| Foot/DEF Auto Mode | ON | Function to turn the airflow from FOOT/DEF on automatically when AUTO MODE is on | ON or OFF | Air Conditioning Amplifier Assembly |
| Foot/DEF Automatic Blow Up Function | ON | Function to increase the blower level automatically when the defroster is on | ON or OFF | Air Conditioning Amplifier Assembly |
| Ambient Temperature Shift | Normal | Function to display shifted ambient temperature versus actual ambient temperature | -3C, -2C, -1C, Normal, +1C, +2C, +3C | Air Conditioning Amplifier Assembly |
| ECO MODE Cancel | OFF | Function to cancel the ECO mode drive when item is on | OFF or ON | Air conditioning amplifier assembly |
| Noise and Vibration Reduction | OFF | Function to change speed of the compressor when item is on | OFF or ON | Air conditioning amplifier assembly |
| Refrigerant Shortage Check | ON | Function to cancel the refrigerant shortage check (check performed during normal operation) when item is off | ON or OFF | Air Conditioning Amplifier Assembly |
| Fan speed increment control | Normal | Function to define how fast the AC blower goes to target speed when first activating the AC | Slow, Normal, Fast | Air Conditioning Amplifier Assembly |