Home › Vehicle Interior › HEATING / AIR CONDITIONING › REFRIGERANT › from 2014.12
RM2170E _58 Vehicle Interior _057042 HEATING / AIR CONDITIONING _0278126 REFRIGERANT A

HEATING / AIR CONDITIONING  REFRIGERANT  REPLACEMENT  


PROCEDURE

Hide 1.RECOVER REFRIGERANT FROM AIR CONDITIONING SYSTEM

a.

Start the hybrid system.


b.

Operate the cooler compressor under the conditions show below:

Item Condition
Engine Speed Idling
Operating Time 3 minutes or more
A/C Switch Status ON
Blower Switch Status HI
Set Temperature MAX COOL

This causes most of the compressor oil from the various components of the A/C system to collect in the A/C compressor.

HINT:

It is not necessary to operate the cooler compressor if the A/C does not operate because of compressor lock, etc.



c.

Stop the engine.


d.

Recover the refrigerant from the A/C system using a refrigerant recovery unit.

HINT:

Use the refrigerant recovery unit in accordance with the manufacturer's instruction manual.



Hide 2.CHARGE AIR CONDITIONING SYSTEM WITH REFRIGERANT

a.

Perform vacuum purging using a vacuum pump or appropriate equipment.


b.

Charge the air conditioning system with refrigerant.

Refrigerant type:

HFC-134a (R134a)


E247093E20
4.51,1.75 4.792,0.927 4.792,0.927 4.885,0.927 false 2.615,0.271 2.823,0.49 0.208,0.219 10 false *a 4.906,0.844 5.115,1.063 0.208,0.219 10 false *b 5.771,1.51 5.979,1.729 0.208,0.219 10 false *c 1.667,3.313 1.938,3.51 0.271,0.198 10 false : *e 3.781,3.063 3.99,3.281 0.208,0.219 10 false *f 0.75,1.552 0.958,1.771 0.208,0.219 10 false *d 4.396,2.25 4.667,2.521 0.271,0.271 10 false *g

Text in Illustration
*a Standard Charge Amount *b Mean Value in Proper Range
*c Overcharged *d High Pressure
*e Sub-cool System *f Refrigerant Amount
*g +/-50 g (+/-1.76 oz) - -

Standard charge amount:

370 to 470 g (13.0 to 16.6 oz)


SST
09985-20010  (09985-02010, 09985-02050, 09985-02060, 09985-02070, 09985-02080, 09985-02090, 09985-02110, 09985-02130, 09985-02140, 09985-02150)

NOTICE:
·

Do not turn the A/C switch on before charging the air conditioning system with refrigerant. Doing so may cause the compressor to work without refrigerant, resulting in overheating of the compressor.

·

The refrigerant amount should be checked by quantity (weight).

·

The graph above is shown for reference only.



HINT:

Ensure that sufficient refrigerant is available to recharge the system when using a refrigerant recovery unit. Refrigerant recovery units are not always able to recover 100% of the refrigerant from an air conditioning system.



Hide 3.WARM UP COMPRESSOR

a.

Keep the A/C switch on for at least 2 minutes to warm up the compressor.

NOTICE:

To prevent damage to the compressor, be sure to warm up the compressor when turning the air conditioning on after removing and installing air conditioning system lines (including the compressor).



Hide 4.INSPECT FOR REFRIGERANT LEAK

a.

After recharging the air conditioning system with refrigerant, inspect for refrigerant leaks using a halogen leak detector.


b.

Carry out the test under the following conditions:

·

Turn the power switch off.

·

Ensure good ventilation (the halogen leak detector may react to volatile gases which are not refrigerant, such as gasoline vapor and exhaust gas).

·

Repeat the inspection 2 or 3 times.

·

Measure the pressure to make sure that there is some refrigerant remaining in the air conditioning system.

Pressure when the compressor is off: approx. 392 to 588 kPa (3.9 to 5.9 kgf/cm2, 57 to 85 psi)



c.
I042222E45
2.552,0.167 2.656,0.167 2.656,0.167 3.063,1.75 false 0.052,0.052 0.198,0.229 0.146,0.177 10 false *a 2.354,0.063 2.5,0.24 0.146,0.177 10 false *1

Using a halogen leak detector, inspect for refrigerant leaks from the air conditioning system.

Text in Illustration
*1 Halogen Leak Detector
*a Inspect for Leak


d.
N014519E23
1.115,1.677 1.438,1.677 false 1.323,0.896 1.323,0.458 true 1.24,0.281 1.396,0.49 0.156,0.208 10 false *2 1.5,1.573 1.677,1.771 0.177,0.198 10 false *1

Bring the halogen leak detector close to the drain hose with the detector power off, and then turn the detector on.

Text in Illustration
*1 Halogen Leak Detector
*2 Drain Hose

HINT:
·

After the blower motor has stopped, leave the cooling unit for more than 15 minutes.

·

Bring the halogen leak detector sensor under the drain hose.

·

When bringing the halogen leak detector close to the drain hose, make sure that the halogen leak detector does not react to volatile gases. If it is not possible to avoid interference from volatile gases, the vehicle should be lifted up to allow checking for leaks.




e.

If a refrigerant leak is not detected from the drain hose, remove the blower motor control from the cooling unit. Insert the halogen leak detector sensor into the unit and check for a leak.


f.

Disconnect the pressure sensor connector and leave it for approximately 20 minutes. Bring the halogen leak detector close to the pressure sensor and check for a leak.

HINT:

When checking for leaks, the presence of oily dirt at a joint can indicate a leak.