Home › Vehicle Interior › HEATING / AIR CONDITIONING › ROOM TEMPERATURE SENSOR
RM2170E _58 Vehicle Interior _057042 HEATING / AIR CONDITIONING _0278136 ROOM TEMPERATURE SENSOR G

HEATING / AIR CONDITIONING  ROOM TEMPERATURE SENSOR  INSPECTION  


PROCEDURE

Hide 88625Q 1.INSPECT ROOM TEMPERATURE SENSOR (COOLER THERMISTOR)

a.

Measure the resistance according to the value(s) in the table below.

E319151E03
1.792,0.417 2.208,0.667 0.417,0.25 2,1.677 2.51,1.323 2.51,1.323 2.646,1.323 false 4.844,1.49 5.25,0.958 5.25,0.958 5.385,0.958 false 2.031,1.073 2.427,0.906 false 1.917,1.073 1.49,0.885 false 0.469,0.26 0.781,0.458 0.313,0.198 10 false *a 2.698,1.25 3.01,1.448 0.313,0.198 10 false *b 4.052,0.271 4.365,0.469 0.313,0.198 10 false *c 5.49,0.833 5.802,1.031 0.313,0.198 10 false *d 6.75,2.49 7.063,2.688 0.313,0.198 10 false *e 4.135,2.406 4.438,2.792 0.302,0.385 10 false 10 4.104,2.563 4.427,2.781 0.323,0.219 10 false (50) 4.583,2.406 4.885,2.792 0.302,0.385 10 false 20 5.042,2.406 5.344,2.792 0.302,0.385 10 false 30 5.5,2.406 5.802,2.792 0.302,0.385 10 false 40 5.938,2.406 6.24,2.792 0.302,0.385 10 false 50 6.375,2.406 6.677,2.792 0.302,0.385 10 false 60 4.542,2.563 4.865,2.781 0.323,0.219 10 false (68) 5.01,2.563 5.333,2.781 0.323,0.219 10 false (86) 5.427,2.563 5.813,2.781 0.385,0.219 10 false (104) 5.865,2.563 6.25,2.781 0.385,0.219 10 false (122) 6.302,2.552 6.688,2.771 0.385,0.219 10 false (140) 3.958,0.521 7.156,0.917 3.198,0.396 10 false 4.0 3.958,0.74 7.156,1.135 3.198,0.396 10 false 3.5 3.958,0.958 7.156,1.354 3.198,0.396 10 false 3.0 3.958,1.177 7.156,1.573 3.198,0.396 10 false 2.5 3.958,1.396 7.156,1.792 3.198,0.396 10 false 2.0 3.958,1.635 7.156,2.031 3.198,0.396 10 false 1.5 3.958,1.854 7.156,2.25 3.198,0.396 10 false 1.0 3.958,2.271 7.156,2.667 3.198,0.396 10 false 0.0 3.958,2.063 7.156,2.458 3.198,0.396 10 false 0.5 2.5,0.802 2.813,1 0.313,0.198 10 false + 1.333,0.781 1.646,0.979 0.313,0.198 10 false - 1.865,0.458 2.333,0.698 0.469,0.24 10 false G31

Standard Resistance:
Tester Connection Condition Specified Condition
G31-1 (+) - G31-2 (-) 10°C (50°F) 3.00 to 3.73 kΩ
G31-1 (+) - G31-2 (-) 15°C (59°F) 2.45 to 2.88 kΩ
G31-1 (+) - G31-2 (-) 20°C (68°F) 1.95 to 2.30 kΩ
G31-1 (+) - G31-2 (-) 25°C (77°F) 1.60 to 1.80 kΩ
G31-1 (+) - G31-2 (-) 30°C (86°F) 1.28 to 1.47 kΩ
G31-1 (+) - G31-2 (-) 35°C (95°F) 1.00 to 1.22 kΩ
G31-1 (+) - G31-2 (-) 40°C (104°F) 0.80 to 1.00 kΩ
G31-1 (+) - G31-2 (-) 45°C (113°F) 0.65 to 0.85 kΩ
G31-1 (+) - G31-2 (-) 50°C (122°F) 0.50 to 0.70 kΩ
G31-1 (+) - G31-2 (-) 55°C (131°F) 0.44 to 0.60 kΩ
G31-1 (+) - G31-2 (-) 60°C (140°F) 0.36 to 0.50 kΩ


If the resistance is not as specified, replace the room temperature sensor (cooler thermistor).

Text in Illustration
*a Component without harness connected
(Room Temperature Sensor (Cooler Thermistor))
*b Sensing Portion
*c Resistance (kΩ)
*d Allowable Range
*e Temperature (°C (°F))

NOTICE:
·

Hold the sensor only by its connector. Touching the sensor may change the resistance value.

·

When measuring, the sensor temperature must be the same as the ambient temperature.



HINT:

As the temperature increases, the resistance decreases (see the graph).