HEATING / AIR CONDITIONING  SOLAR SENSOR  INSPECTION  


PROCEDURE

Hide 88625H 1.INSPECT COOLER THERMISTOR (SOLAR SENSOR)

a.

Disconnect the G61 cooler thermistor (solar sensor) connector.


b.
U159701E01
0.209,0.228 0.395,0.391 0.186,0.162 10 *a 0.689,1.004 1.006,1.167 0.316,0.162 10 SS+ 2.434,0.978 2.807,1.141 0.373,0.162 10 SS- 1.559,0.455 1.881,0.636 0.322,0.181 10 G61 1.827,1.372 2.184,1.075 2.184,1.075 2.386,1.075 false 1.622,1.382 1.265,1.085 1.265,1.085 1.064,1.085 false

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
G61-1 (SS+) - G61-2 (SS-) Power switch off Below 1 V
G61-1 (SS+) - G61-2 (SS-) Power switch on (IG) 4.75 to 5.25 V


Text in Illustration
*a Front view of wire harness connector
(to Cooler Thermistor (Solar Sensor))

If the voltage is not as specified, repair or replace the wire harness or connector.



c.

Reconnect the G61 cooler thermistor (solar sensor) connector.


d.
U159700E02
1.885,1.146 2.333,0.625 2.333,0.625 2.594,0.625 false 1.531,1.135 1.052,0.604 1.052,0.604 0.781,0.604 false 0.156,0.104 0.417,0.375 0.26,0.271 10 false *a 0.5,0.521 0.917,0.708 0.417,0.188 10 false SS- 2.656,0.531 3.031,0.698 0.375,0.167 10 false SS+ 0.396,1.156 0.719,1.333 0.323,0.177 10 false G61

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
G61-1 (SS+) - G61-2 (SS-) Sensor is subjected to electric light 0.8 to 4.3 V
G61-1 (SS+) - G61-2 (SS-) Sensor is covered with a cloth Below 0.8 V


Text in Illustration
*a Component with harness connected
(Cooler Thermistor (Solar Sensor))

NOTICE:
·

The connection procedure for using a digital tester such as a TOYOTA electrical tester is shown above. When using an analog tester, connect the negative (-) lead to terminal 1 and the positive (+) lead to terminal 2 of the cooler thermistor (solar sensor).

·

Do not bring the positive and negative tester probes too close to each other as a short circuit may occur.



HINT:
·

Use an incandescent light for inspection. Bring it within about 30 cm (11.8 in.) of the cooler thermistor (solar sensor).

·

As the inspection light is moved away from the sensor, the voltage decreases.



If the voltage is not as specified, replace the cooler thermistor (solar sensor).