Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING PRESSURE SENSOR
RM2170E _58 Vehicle Interior _057042 HEATING / AIR CONDITIONING _0278140 AIR CONDITIONING PRESSURE SENSOR G

HEATING / AIR CONDITIONING  AIR CONDITIONING PRESSURE SENSOR  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 88719A 1.INSPECT AIR CONDITIONING PRESSURE SENSOR

a.

Check the wire harness.

i.

Disconnect the A25 air conditioning pressure sensor connector.


ii.

Disconnect the G34 air conditioning amplifier assembly connector.


iii.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A25-1 (-) - G34-13 (SG-2) Always Below 1 Ω
A25-2 (PR) - G34-9 (PRE) Always Below 1 Ω
A25-3 (+) - G34-10 (S5-3) Always Below 1 Ω
A25-1 (-) - Body ground Always 10 kΩ or higher
A25-2 (PR) - Body ground Always 10 kΩ or higher
A25-3 (+) - Body ground Always 10 kΩ or higher


If the resistance is not as specified, repair the wire harness.



iv.

Reconnect the G34 air conditioning amplifier assembly connector.


v.

Turn the power switch on (IG).


vi.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch condition Specified Condition
A25-3 (+) - Body ground Power switch on (IG) 4.75 to 5.25 V
A25-3 (+) - Body ground Power switch off Below 1 V


If the voltage is not as specified, repair the wire harness or replace air conditioning amplifier assembly.




b.

Check the air conditioning pressure sensor.

i.

Install a manifold gauge set.


ii.

Connect the connector to the air conditioning pressure sensor.


iii.

Turn the power switch on (READY).


iv.

Turn the A/C switch on.


v.
U159661E02
1.573,1.01 1.969,1.604 false 1.323,1 0.927,1.594 false 0.177,0.167 0.333,0.313 0.156,0.146 10 false *a 1.865,1.615 2.167,1.76 0.302,0.146 10 false PRE 0.729,1.615 1.125,1.76 0.396,0.146 10 false SG-2 1.354,0.385 1.656,0.542 0.302,0.156 10 false G34

Measure the voltage according to the value(s) in the table below.

HINT:

Check from the rear of the connector while it is connected to the air conditioning amplifier.


Standard Voltage:
Tester Connection Condition Specified Condition
G34-9 (PRE) - G34-13 (SG-2) Refrigerant pressure:
(less than 3025 kPa (30.9 kgf/cm2, 439 psi) and more than 176 kPa (1.8 kgf/cm2, 25 psi))
0.74 to 4.62 V


Text in Illustration
*a Component with harness connected
(Air Conditioning Amplifier)

If the voltage is not as specified, replace the air conditioning pressure sensor.