Home › Vehicle Interior › HEATING / AIR CONDITIONING › SOLAR SENSOR › from 2017.06
RM2170E _58 Vehicle Interior _057042 HEATING / AIR CONDITIONING _0278139 SOLAR SENSOR G

HEATING / AIR CONDITIONING  SOLAR SENSOR  INSPECTION  


PROCEDURE

Hide 88625H 1.INSPECT AUTOMATIC LIGHT CONTROL SENSOR (w/ Automatic Light Control)

a.

Disconnect the G56 automatic light control sensor connector.


b.
E222418C13
1.479,0.104 1.938,0.385 0.458,0.281 1.021,1.198 1.51,1.198 false 1.948,1.417 2.427,1.688 false 0.167,0.115 0.448,0.333 0.281,0.219 10 false *a 0.594,1.125 1.313,1.302 0.719,0.177 10 false CLTB 2.479,1.677 3.146,1.885 0.667,0.208 10 false CLTE 1.573,0.156 1.948,0.333 0.375,0.177 10 false G90
*a Front view of wire harness connector
(to Automatic Light Control Sensor)


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
G56-3 (CLTB) - G56-5 (CLTE) Ignition switch off Below 1 V
Ignition switch ON (IG) 4.75 to 5.25 V


If the voltage is not as specified, repair or replace the wire harness or connector.



c.

Connect the G56 automatic light control sensor connector.


d.
E222419C09
0.646,0.469 1.104,0.75 0.458,0.281 1.542,1.219 0.938,1.385 false 1.906,0.875 2.469,0.75 false 0.146,0.115 0.438,0.375 0.292,0.26 10 false *a 2.521,0.656 2.948,0.875 0.427,0.219 10 false TSD 0.51,1.323 0.969,1.51 0.458,0.188 10 false CLTE 0.74,0.542 1.135,0.75 0.396,0.208 10 false G90
*a Component with harness connected
(Automatic Light Control Sensor)


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
G56-1 (TSD) - G56-5 (CLTE) Sensor is subjected to electric light 0.8 to 4.3 V
Sensor is covered with a cloth Below 0.8 V


NOTICE:
·

The connection procedure for using a digital tester such as a TOYOTA electrical tester is shown above. When using an analog tester, connect the negative (-) lead to terminal 1 and the positive (+) lead to terminal 2 of the automatic light control sensor.

·

Do not bring the positive and negative tester probes too close to each other as a short circuit may occur.



HINT:
·

Use an incandescent light for inspection. Bring it within about 30 cm (11.8 in.) of the automatic light control sensor.

·

As the inspection light is moved away from the sensor, the should decrease.



If the voltage is not as specified, replace the automatic light control sensor.



Hide 88625H 2.INSPECT COOLER THERMISTOR (SOLAR SENSOR) (w/o Automatic Light Control)

a.

Disconnect the G61 cooler thermistor (solar sensor) connector.


b.
E373252C01
1.469,0.396 1.927,0.625 0.458,0.229 0.917,1.083 1.083,1.083 1.083,1.083 1.625,1.333 false 2.646,1.052 2.521,1.052 2.521,1.052 1.823,1.323 false 0.188,0.156 0.5,0.354 0.313,0.198 10 false *a 0.583,1.01 0.896,1.208 0.313,0.198 10 false SS+ 2.729,0.979 3.042,1.177 0.313,0.198 10 false SS- 1.563,0.427 1.875,0.625 0.313,0.198 10 false G61
*a Front view of wire harness connector
(to Cooler Thermistor (Solar Sensor))


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
G61-1 (SS+) - G61-2 (SS-) Ignition switch off Below 1 V
Ignition switch ON (IG) 4.75 to 5.25 V


If the voltage is not as specified, repair or replace the wire harness or connector.



c.

Connect the G61 cooler thermistor (solar sensor) connector.


d.
E373253C01
1.479,0.104 1.927,0.354 0.448,0.25 1.594,1.344 1,1.854 1,1.854 0.833,1.854 true 1.844,1.344 2.385,1.917 2.385,1.917 2.552,1.917 true 0.167,0.125 0.479,0.323 0.313,0.198 10 false *a 0.552,1.76 0.865,1.958 0.313,0.198 10 false SS- 2.604,1.823 2.917,2.021 0.313,0.198 10 false SS+ 1.563,0.135 1.875,0.333 0.313,0.198 10 false G61
*a Component with harness connected
(Cooler Thermistor (Solar Sensor))


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
G61-1 (SS+) - G61-2 (SS-) Sensor is subjected to electric light 0.8 to 4.3 V
Sensor is covered with a cloth Below 0.8 V


NOTICE:
·

The connection procedure for using a digital tester such as a TOYOTA electrical tester is shown above. When using an analog tester, connect the negative (-) lead to terminal 1 and the positive (+) lead to terminal 2 of the cooler thermistor (solar sensor).

·

Do not bring the positive and negative tester probes too close to each other as a short circuit may occur.



HINT:
·

Use an incandescent light for inspection. Bring it within about 30 cm (11.8 in.) of the cooler thermistor (solar sensor).

·

As the inspection light is moved away from the sensor, the should decrease.



If the voltage is not as specified, replace the cooler thermistor (solar sensor).