Home › Engine / Hybrid System › 1NZ-FXE (ENGINE CONTROL) › SFI SYSTEM(w/ Canister Pump Module) › 2017.06–2018.08
RM2170E _51 Engine / Hybrid System _057003 1NZ-FXE ENGINE CONTROL _0320444 SFI SYSTEM(w/ Canister Pump Module) C

1NZ-FXE ENGINE CONTROL  SFI SYSTEM(w/ Canister Pump Module)  P043E  Evaporative Emission System Leak Detection Reference Orifice Low Flow  P043F  Evaporative Emission System Leak Detection Reference Orifice High Flow  P2401  Evaporative Emission Leak Detection Pump Stuck OFF  P2402  Evaporative Emission Leak Detection Pump Stuck ON  P2419  Evaporative Emission Pressure Switching Valve Stuck ON  


DTC SUMMARY

DTC No. Monitoring Item Malfunction Detection Condition Trouble Area Detection Timing Detection Logic
P043E Reference orifice clogged P043E, P043F, P2401, P2402 and P2419 stored when one of following conditions met during key-off EVAP monitor:
·

Reference orifice clogged

·

Reference orifice high-flow

·

Leak detection pump off malfunction

·

Leak detection pump on malfunction

·

Vent valve on (closed) malfunction


·

Canister pump module

·

Connector/wire harness (Canister pump module - ECM)

·

ECM


While power switch off 2 trip
P043F Reference orifice high-flow
P2401 Leak detection pump stuck off
P2402 Leak detection pump stuck on
P2419 Vent valve stuck closed

HINT:

The reference orifice is located inside the canister pump module.


DESCRIPTION

The description can be found in EVAP (Evaporative Emission) System.

Click hereEngine / Hybrid System>1NZ-FXE (ENGINE CONTROL)>SFI SYSTEM(w/ Canister Pump Module)>EVAP System

MONITOR DESCRIPTION

5 hours* after the power switch is turned off, the leak detection pump creates negative pressure (vacuum) in the EVAP system. The ECM monitors for leaks and actuator malfunctions based on the EVAP pressure.

HINT:

*: If the engine coolant temperature is not less than 35°C (95°F) 5 hours after the power switch is turned off, the monitor check starts 2 hours later. If it is still not less than 35°C (95°F) 7 hours after the power switch is turned off, the monitor check starts 2.5 hours later.


Sequence Operation Description Duration
- ECM activation Activated by soak timer, 5, 7 or 9.5 hours after power switch turned off. -
A Atmospheric pressure measurement Vent valve is turned off (vent) and EVAP system pressure is measured by ECM in order to register atmospheric pressure.
If pressure in EVAP system is not between 70 kPa(abs) and 110 kPa(abs) [525 mmHg(abs) and 825 mmHg(abs)], ECM cancels EVAP system monitor.
60 seconds
B First reference pressure measurement In order to determine reference pressure, leak detection pump creates negative pressure (vacuum) through reference orifice and then ECM checks if leak detection pump and vent valve operate normally. 360 seconds
C EVAP system pressure measurement Vent valve is turned on (closed) to shut EVAP system.
Negative pressure (vacuum) is created in EVAP system, and EVAP system pressure is then measured.
Write down measured value as it will be used in leak check
If EVAP pressure does not stabilize within 15 minutes, ECM cancels EVAP system monitor.
15 minutes*
D Purge VSV monitor Purge VSV is opened and then EVAP system pressure is measured by ECM.
Large increase indicates normal.
10 seconds
E Second reference pressure measurement After second reference pressure measurement, leak check is performed by comparing first and second reference pressure measurements.
If stabilized system pressure is higher than second reference pressure, ECM determines that EVAP system is leaking.
60 seconds
- Final check Atmospheric pressure is measured and then monitoring result is recorded by ECM. -

*: If only a small amount of fuel is in the fuel tank, it takes longer for the EVAP pressure to stabilize.

A269951E02
1.219,0.771 1.198,0.906 false 1.219,3.135 1.198,3.26 false 1.625,2.167 1.75,2.417 false 1.146,1.729 0.813,1.813 false 1.604,0.927 1.635,0.427 1.635,0.427 1.719,0.427 false 2.271,0.885 2.302,0.417 2.302,0.417 2.385,0.417 false 1.792,1.594 1.896,1.24 1.896,1.24 1.979,1.24 false 1.833,3.948 1.938,3.583 1.938,3.583 2.021,3.583 false 5.094,3.125 5.063,3.25 false 5.719,3.958 5.823,3.594 5.823,3.594 5.906,3.594 false 5.083,0.771 5.052,0.906 false 5.5,2.167 5.635,2.417 false 5.656,1.594 5.771,1.24 5.771,1.24 5.854,1.24 false 1.469,1.958 0.802,2.208 false 1.417,1.344 1.292,1.271 1.292,1.271 1.208,1.271 false 2.333,1.427 2.344,1.229 2.344,1.229 2.427,1.229 false 2.813,1.927 2.833,1.771 2.833,1.771 2.906,1.771 false 1.594,4.51 0.896,4.51 false 5.448,4.51 4.75,4.51 false 0.365,0.135 0.552,0.313 0.188,0.177 10 false *a 1.115,0.906 1.302,1.083 0.188,0.177 10 false *1 1.719,0.333 1.906,0.51 0.188,0.177 10 false *9 4.281,0.135 4.469,0.313 0.188,0.177 10 false *b 4.281,2.688 4.469,2.865 0.188,0.177 10 false *d 0.365,2.688 0.552,2.865 0.188,0.177 10 false *c 1.115,3.271 1.302,3.448 0.188,0.177 10 false *1 1.677,2.417 1.865,2.594 0.188,0.177 10 false *5 0.729,4.427 0.917,4.604 0.188,0.177 10 false *6 1.99,1.156 2.156,1.333 0.167,0.177 10 false *3 2.042,3.5 2.208,3.677 0.167,0.177 10 false *4 3.458,3.354 3.625,3.531 0.167,0.177 10 false *e 3.458,3.74 3.625,3.917 0.167,0.177 10 false *f 5,3.271 5.188,3.448 0.188,0.177 10 false *2 5.917,3.51 6.083,3.688 0.167,0.177 10 false *4 4.979,0.917 5.167,1.094 0.188,0.177 10 false *1 5.563,2.417 5.75,2.594 0.188,0.177 10 false *6 5.854,1.156 6.021,1.333 0.167,0.177 10 false *3 0.979,1.188 1.219,1.365 0.24,0.177 10 false *10 0.667,1.729 0.833,1.906 0.167,0.177 10 false *7 0.646,2.135 0.813,2.313 0.167,0.177 10 false *8 2.958,1.708 3.208,1.885 0.25,0.177 10 false *12 2.469,1.167 2.719,1.344 0.25,0.177 10 false *11 2.438,0.354 2.688,0.531 0.25,0.177 10 false *13 4.594,4.438 4.781,4.615 0.188,0.177 10 false *6

Text in Illustration
*1 Purge VSV: Off (Closed) *2 Purge VSV: On (Open)
*3 Vent Valve: Off (Vent) *4 Vent Valve: On (Closed)
*5 Leak Detection Pump: Off *6 Leak Detection Pump: On
*7 Reference Orifice (0.02 inch) *8 Canister Pressure Sensor
*9 Canister *10 No. 1 Canister
*11 Canister Pump Module *12 Canister Filter
*13 Fuel Tank - -
*a Operation A:
Atmospheric Pressure Measurement
*b Operation B, E:
Reference Pressure Measurement
*c Operation C:
EVAP System Pressure Measurement
*d Operation D:
Purge VSV Monitor
*e Atmospheric Pressure *f Negative Pressure

The leak detection pump creates negative pressure through the reference orifice (in operation B and E). When the system is normal, the EVAP pressure is between 97 to 100 kPa(abs) [726 to 750 mmHg(abs)]* and saturated within a minute. If not, the ECM interprets this as a malfunction. The ECM illuminates the MIL and stores a DTC if this malfunction is detected in consecutive drive cycles.

*: Typical value.

A293468E03
0.104,0.042 3.167,0.313 3.063,0.271 10 false EVAP Pressure during EVAP key-off monitor 0.406,0.531 1.219,0.75 0.813,0.219 10 false Purge VSV 0.448,1.156 1.26,1.375 0.813,0.219 10 false Vent Valve 0.188,1.417 1.167,1.792 0.979,0.375 10 false Leak Detection Pump 0.135,2.031 1.104,2.25 0.969,0.219 10 false EVAP Pressure 0.25,2.417 1.219,2.635 0.969,0.219 10 false 101 kPa(abs) 0.25,2.76 1.219,2.979 0.969,0.219 10 false 100 kPa(abs) 0.323,3.792 1.292,4.01 0.969,0.219 10 false 97 kPa(abs) 0.49,4.073 1.458,4.292 0.969,0.219 10 false Sequence 0.146,4.344 1.115,4.563 0.969,0.219 10 false Time (Seconds) 1.688,4.083 1.938,4.333 0.25,0.25 10 false A 1.667,4.323 1.917,4.573 0.25,0.25 10 false 60 2.5,4.323 2.75,4.573 0.25,0.25 10 false 360 2.573,4.083 2.823,4.333 0.25,0.25 10 false B 3.906,4.083 4.156,4.333 0.25,0.25 10 false C 3.406,4.323 4.76,4.563 1.354,0.24 10 false Within 15 minutes 5.125,4.323 5.375,4.5 0.25,0.177 10 false 10 5.688,4.323 5.938,4.5 0.25,0.177 10 false 60 5.167,4.083 5.417,4.26 0.25,0.177 10 false D 5.719,4.083 5.969,4.26 0.25,0.177 10 false E 3.74,2.656 4.24,2.906 0.5,0.25 10 false : OK 3.74,2.969 4.917,3.229 1.177,0.26 10 false : Malfunction 3.844,1.531 4.344,1.781 0.5,0.25 10 false ON 3.844,1.052 4.344,1.302 0.5,0.25 10 false ON 5.083,0.49 5.583,0.74 0.5,0.25 10 false ON 6.292,0.292 6.969,0.542 0.677,0.25 10 false ON: Open 6.292,0.615 7.104,0.833 0.813,0.219 10 false OFF: Closed 6.292,0.906 7.104,1.156 0.813,0.25 10 false ON: Closed 6.292,1.167 6.969,1.417 0.677,0.25 10 false OFF: Vent

MONITOR STRATEGY

Required Sensors/Components (Main) Canister pump module
Required Sensors/Components (Related) -
Frequency of Operation Once per driving cycle

CONFIRMATION DRIVING PATTERN

NOTICE:
·

The Evaporative System Check (Automatic Mode) consists of 6 steps performed automatically by the GTS. It takes a maximum of approximately 24 minutes.

·

Do not perform the Evaporative System Check when the fuel tank is higher than 90% full because the cut-off valve may be closed, making the fuel tank leak check unavailable.

·

Do not run the engine during this operation.

·

When the temperature of the fuel is 35°C (95°F) or higher, a large amount of vapor forms and any check results become inaccurate. When performing the Evaporative System Check, keep the fuel temperature less than 35°C (95°F).



1.

Connect the GTS to the DLC3.

2.

Turn the power switch on (IG) and turn the GTS on.

3.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

4.

Turn the power switch off and wait for at least 30 seconds.

5.

Turn the power switch on (IG) and turn the GTS on.

6.

Enter the following menus: Powertrain / Engine and ECT / Utility / Evaporative System Check / Automatic Mode.

7.

After the "Evaporative System Check" is completed, check for All Readiness by entering the following menus: Powertrain / Engine and ECT / Utility / All Readiness.

8.

Input the DTC: P043E, P043F, P2401, P2402 or P2419.

9.

Check the DTC judgment result.

GTS Display Description
NORMAL
·

DTC judgment completed

·

System normal


ABNORMAL
·

DTC judgment completed

·

System abnormal


INCOMPLETE
·

DTC judgment not completed

·

Perform driving pattern after confirming DTC enabling conditions


N/A
·

Unable to perform DTC judgment

·

Number of DTCs which do not fulfill DTC preconditions has reached ECU memory limit



HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.




PROCEDURE

1.REFER TO THE EVAP SYSTEM

NEXT

END