POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY
| *A | for LHD | *B | for RHD |
Disconnect the J1*1, H1*2 power window regulator master switch assembly connector.
*1: for LHD
*2: for RHD
Measure the voltage and resistance according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| J1-1 (E) - Body ground | LA - Body ground | Ground | Always | Below 1 Ω |
| J1-6 (B) - J1-1 (E) | LA-GR - LA | Power supply | Power switch on (IG) | 11 to 14 V |
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| J1-1 (E) - Body ground | LA - Body ground | Ground | Always | Below 1 Ω |
| J1-7 (B) - J1-1 (E) | LA-GR - LA | Power supply | Power switch on (IG) | 11 to 14 V |
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| H1-9 (E) - Body ground | LA - Body ground | Ground | Always | Below 1 Ω |
| H1-6 (B) - H1-9 (E) | LA-GR - LA | Power supply | Power switch on (IG) | 11 to 14 V |
Reconnect the J1*1, H1*2 power window regulator master switch assembly.
*1: for LHD
*2: for RHD
Measure the voltage according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| J1-8 (U) - J1-1 (E) | R - LA | Power window motor UP output | Power switch on (IG), driver door power window switch OFF → UP (Manual operation) | 11 to 14 V → Below 1 V |
| J1-4 (AUTO) - J1-1 (E) | R - LA | Power window motor AUTO UP output | Power switch on (IG), driver door power window fully open → driver door power window switch UP (AUTO UP position) → driver door power window fully closed | 11 to 14 V → Below 1 V → 11 to 14 V |
| Power window motor AUTO DOWN output | Power switch on (IG), driver door power window fully closed → driver door power window switch DOWN (AUTO DOWN position) → driver door power window fully open | 11 to 14 V → Below 1 V → 11 to 14 V | ||
| J1-5 (D) - J1-1 (E) | G - LA | Power window motor DOWN output | Power switch on (IG), driver door power window switch OFF → DOWN (Manual operation) | 11 to 14 V → Below 1 V |
| J1-16 (U) - J1-1 (E) | LA-W - LA | Power window motor UP output | Power switch on (IG), front passenger door power window switch OFF → UP (Manual operation) | Below 1 V → 11 to 14 V |
| J1-15 (D) - J1-1 (E) | LA-P - LA | Power window motor DOWN output | Power switch on (IG), front passenger door power window switch OFF → DOWN (Manual operation) | Below 1 V → 11 to 14 V |
| J1-12 (U) - J1-1 (E) | LA-Y - LA | Power window motor UP output | Power switch on (IG), rear LH door power window switch OFF → UP (Manual operation) | Below 1 V → 11 to 14 V |
| J1-13 (D) - J1-1 (E) | LA-B - LA | Power window motor DOWN output | Power switch on (IG), rear LH door power window switch OFF → DOWN (Manual operation) | Below 1 V → 11 to 14 V |
| J1-10 (U) - J1-1 (E) | LA-R - LA | Power window motor UP output | Power switch on (IG), rear RH door power window switch OFF → UP (Manual operation) | Below 1 V → 11 to 14 V |
| J1-18 (D) - J1-1 (E) | LA-G - LA | Power window motor DOWN output | Power switch on (IG), rear RH door power window switch OFF → DOWN (Manual operation) | Below 1 V → 11 to 14 V |
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| J1-6 (U) - J1-1 (E) | R - LA | Power window motor UP output | Power switch on (IG), driver door power window switch OFF → UP (Manual operation) | 11 to 14 V → Below 1 V |
| J1-4 (AUTO) - J1-1 (E) | R - LA | Power window motor AUTO UP output | Power switch on (IG), driver door power window fully open → driver door power window switch UP (AUTO UP position) → driver door power window fully closed | 11 to 14 V → Below 1 V → 11 to 14 V |
| Power window motor AUTO DOWN output | Power switch on (IG), driver door power window fully closed → driver door power window switch DOWN (AUTO DOWN position) → driver door power window fully open | 11 to 14 V → Below 1 V → 11 to 14 V | ||
| J1-3 (D) - J1-1 (E) | G - LA | Power window motor DOWN output | Power switch on (IG), driver door power window switch OFF → DOWN (Manual operation) | 11 to 14 V → Below 1 V |
| J1-10 (U) - J1-1 (E) | LA-W - LA | Power window motor UP output | Power switch on (IG), front passenger door power window switch OFF → UP (Manual operation) | Below 1 V → 11 to 14 V |
| J1-18 (D) - J1-1 (E) | LA-P - LA | Power window motor DOWN output | Power switch on (IG), front passenger door power window switch OFF → DOWN (Manual operation) | Below 1 V → 11 to 14 V |
| J1-12 (U) - J1-1 (E) | LA-Y - LA | Power window motor UP output | Power switch on (IG), rear LH door power window switch OFF → UP (Manual operation) | Below 1 V → 11 to 14 V |
| J1-13 (D) - J1-1 (E) | LA-B - LA | Power window motor DOWN output | Power switch on (IG), rear LH door power window switch OFF → DOWN (Manual operation) | Below 1 V → 11 to 14 V |
| J1-15 (U) - J1-1 (E) | LA-R - LA | Power window motor UP output | Power switch on (IG), rear RH door power window switch OFF → UP (Manual operation) | Below 1 V → 11 to 14 V |
| J1-16 (D) - J1-1 (E) | LA-G - LA | Power window motor DOWN output | Power switch on (IG), rear RH door power window switch OFF → DOWN (Manual operation) | Below 1 V → 11 to 14 V |
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| H1-1 (U) - H1-9 (E) | G - LA | Power window motor UP output | Power switch on (IG), driver door power window switch OFF → UP (Manual operation) | 11 to 14 V → Below 1 V |
| H1-4 (AUTO) - H1-9 (E) | R - LA | Power window motor AUTO UP output | Power switch on (IG), driver door power window fully open → driver door power window switch UP (AUTO UP position) → driver door power window fully closed | 11 to 14 V → Below 1 V → 11 to 14 V |
| Power window motor AUTO DOWN output | Power switch on (IG), driver door power window fully closed → driver door power window switch DOWN (AUTO DOWN position) → driver door power window fully open | 11 to 14 V → Below 1 V → 11 to 14 V | ||
| H1-5 (D) - H1-9 (E) | R - LA | Power window motor DOWN output | Power switch on (IG), driver door power window switch OFF → DOWN (Manual operation) | 11 to 14 V → Below 1 V |
| H1-12 (U) - H1-9 (E) | LA-W - LA | Power window motor UP output | Power switch on (IG), front passenger door power window switch OFF → UP (Manual operation) | Below 1 V → 11 to 14 V |
| H1-13 (D) - H1-9 (E) | LA-P - LA | Power window motor DOWN output | Power switch on (IG), front passenger door power window switch OFF → DOWN (Manual operation) | Below 1 V → 11 to 14 V |
| H1-18 (U) - H1-9 (E) | LA-Y - LA | Power window motor UP output | Power switch on (IG), rear LH door power window switch OFF → UP (Manual operation) | Below 1 V → 11 to 14 V |
| H1-10 (D) - H1-9 (E) | LA-B - LA | Power window motor DOWN output | Power switch on (IG), rear LH door power window switch OFF → DOWN (Manual operation) | Below 1 V → 11 to 14 V |
| H1-16 (U) - H1-9 (E) | LA-R - LA | Power window motor UP output | Power switch on (IG), rear RH door power window switch OFF → UP (Manual operation) | Below 1 V → 11 to 14 V |
| H1-15 (D) - H1-9 (E) | LA-G - LA | Power window motor DOWN output | Power switch on (IG), rear RH door power window switch OFF → DOWN (Manual operation) | Below 1 V → 11 to 14 V |
CHECK POWER WINDOW REGULATOR SWITCH ASSEMBLY (for Front Passenger Door)
| *A | for LHD | *B | for RHD |
Disconnect the H2*1,J2*2 power window regulator switch assembly (for front passenger door) connector.
*1: for LHD
*2: for RHD
Measure the voltage according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| H2-3 (B) - Body ground | LA-L - Body ground | Power supply | Power switch on (IG) | 11 to 14 V |
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| J2-3 (B) - Body ground | LA-L - Body ground | Power supply | Power switch on (IG) | 11 to 14 V |
Reconnect the H2*1,J2*2 power window regulator switch assembly (for front passenger door).
*1: for LHD
*2: for RHD
Measure the voltage according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| H2-4 (U) - Body ground | LA-R - Body ground | Power window motor UP output | Power switch on (IG), front passenger door power window switch OFF → UP (Manual operation) | Below 1 V → 11 to 14 V |
| H2-1 (D) - Body ground | LA-G - Body ground | Power window motor DOWN output | Power switch on (IG), front passenger door power window switch OFF → DOWN (Manual operation) | Below 1 V → 11 to 14 V |
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| J2-4 (U) - Body ground | LA-R - Body ground | Power window motor UP output | Power switch on (IG), front passenger door power window switch OFF → UP (Manual operation) | Below 1 V → 11 to 14 V |
| J2-1 (D) - Body ground | LA-G - Body ground | Power window motor DOWN output | Power switch on (IG), front passenger door power window switch OFF → DOWN (Manual operation) | Below 1 V → 11 to 14 V |
CHECK POWER WINDOW REGULATOR SWITCH ASSEMBLY (for Rear LH Door)
Disconnect the L1 power window regulator switch assembly (for rear LH door) connector.
Measure the voltage according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| L1-3 (B) - Body ground | LA-SB - Body ground | Power supply | Power switch on (IG) | 11 to 14 V |
Reconnect the L1 power window regulator switch assembly (for rear LH door).
Measure the voltage according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| L1-4 (U) - Body ground | LA-Y - Body ground | Power window motor UP output | Power switch on (IG), rear LH door power window switch OFF → UP (Manual operation) | Below 1 V → 11 to 14 V |
| L1-1 (D) - Body ground | LA-B - Body ground | Power window motor DOWN output | Power switch on (IG), rear LH door power window switch OFF → DOWN (Manual operation) | Below 1 V → 11 to 14 V |
CHECK POWER WINDOW REGULATOR SWITCH ASSEMBLY (for Rear RH Door)
Disconnect the K1 power window regulator switch assembly (for rear RH door) connector.
Measure the voltage according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| K1-3 (B) - Body ground | LA-SB - Body ground | Power supply | Power switch on (IG) | 11 to 14 V |
Reconnect the K1 power window regulator switch assembly (for rear RH door) connector.
Measure the voltage according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| K1-4 (U) - Body ground | LA-Y - Body ground | Power window motor UP output | Power switch on (IG), rear RH door power window switch OFF → UP (Manual operation) | Below 1 V → 11 to 14 V |
| K1-1 (D) - Body ground | LA-B - Body ground | Power window motor DOWN output | Power switch on (IG), rear RH door power window switch OFF → DOWN (Manual operation) | Below 1 V → 11 to 14 V |
CHECK POWER WINDOW REGULATOR MOTOR ASSEMBLY (for Driver Door)
| *A | for LHD | *B | for RHD |
Disconnect the J3*1, H3*2 power window regulator motor assembly (for driver door) connector.
*1: for LHD
*2: for RHD
Measure the voltage and resistance according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| J3-1 (GND) - Body ground | LA - Body ground | Ground | Always | Below 1 Ω |
| J3-2 (B) - Body ground | LA-G - Body ground | Power supply | Power switch off | 11 to 14 V |
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| H3-1 (GND) - Body ground | LA - Body ground | Ground | Always | Below 1 Ω |
| H3-2 (B) - Body ground | LA-LG - Body ground | Power supply | Power switch off | 11 to 14 V |
Reconnect the J3*1, H3*2 power window regulator motor assembly (for driver door) connector.
*1: for LHD
*2: for RHD
Measure the voltage according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| J3-4 (AUTO) - J3-1 (GND) | R - LA | Power window motor AUTO UP input | Power switch on (IG), driver door power window fully open | 11 to 14 V |
| J3-4 (AUTO) - J3-1 (GND) | R - LA | Power window motor AUTO UP input | Power switch on (IG), driver door power window moving, power window regulator switch assembly fully pulled up (Automatic operation) | Below 1 V |
| J3-4 (AUTO) - J3-1 (GND) | R - LA | Power window motor AUTO UP input | Power switch on (IG), driver door power window fully closed | 11 to 14 V |
| J3-4 (AUTO) - J3-1 (GND) | R - LA | Power window motor AUTO DOWN input | Power switch on (IG), driver door power window fully closed | 11 to 14 V |
| J3-4 (AUTO) - J3-1 (GND) | R - LA | Power window motor AUTO DOWN input | Power switch on (IG), driver door power window moving, power window regulator switch assembly fully pushed down (Automatic operation) | Below 1 V |
| J3-4 (AUTO) - J3-1 (GND) | R - LA | Power window motor AUTO DOWN input | Power switch on (IG), driver door power window fully open | 11 to 14 V |
| J3-5 (LED) - J3-1 (GND) | W - LA | LED illumination signal | Power switch on (IG) | 11 to 14 V |
| J3-5 (LED) - J3-1 (GND) | W - LA | LED illumination signal | Approximately 43 seconds after power switch turned off | Below 1 V |
| J3-7 (DOWN) - J3-1 (GND) | G - LA | Power window motor DOWN input | Power switch on (IG), driver door power window regulator switch not pushed or pulled | 11 to 14 V |
| J3-7 (DOWN) - J3-1 (GND) | G - LA | Power window motor DOWN input | Power switch on (IG), driver door power window regulator switch pushed halfway down (Manual operation) | Below 1 V |
| J3-7 (DOWN) - J3-1 (GND) | G - LA | Power window motor DOWN input | Power switch on (IG), driver door power window fully closed | 11 to 14 V |
| J3-7 (DOWN) - J3-1 (GND) | G - LA | Power window motor DOWN input | Power switch on (IG), driver door power window regulator switch fully pushed down (Automatic position) | Below 1 V |
| J3-7 (DOWN) - J3-1 (GND) | G - LA | Power window motor DOWN input | Power switch on (IG), driver door power window fully open | 11 to 14 V |
| J3-10 (UP) - J3-1 (GND) | R - LA | Power window motor UP input | Power switch on (IG), driver door power window regulator switch not pushed or pulled | 11 to 14 V |
| J3-10 (UP) - J3-1 (GND) | R - LA | Power window motor UP input | Power switch on (IG), driver door power window regulator switch pulled halfway up (Manual operation) | Below 1 V |
| J3-10 (UP) - J3-1 (GND) | R - LA | Power window motor UP input | Power switch on (IG), driver door power window fully open | 11 to 14 V |
| J3-10 (UP) - J3-1 (GND) | R - LA | Power window motor UP input | Power switch on (IG), driver door power window regulator switch fully pulled up (Automatic operation) | Below 1 V |
| J3-10 (UP) - J3-1 (GND) | R - LA | Power window motor UP input | Power switch on (IG), driver door power window fully closed | 11 to 14 V |
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| H3-4 (AUTO) - H3-1 (GND) | R - LA | Power window motor AUTO UP input | Power switch on (IG), driver door power window fully open | 11 to 14 V |
| H3-4 (AUTO) - H3-1 (GND) | R - LA | Power window motor AUTO UP input | Power switch on (IG), driver door power window moving, power window regulator switch assembly fully pulled up (Automatic operation) | Below 1 V |
| H3-4 (AUTO) - H3-1 (GND) | R - LA | Power window motor AUTO UP input | Power switch on (IG), driver door power window fully closed | 11 to 14 V |
| H3-4 (AUTO) - H3-1 (GND) | R - LA | Power window motor AUTO DOWN input | Power switch on (IG), driver door power window fully closed | 11 to 14 V |
| H3-4 (AUTO) - H3-1 (GND) | R - LA | Power window motor AUTO DOWN input | Power switch on (IG), driver door power window moving, power window regulator switch assembly fully pushed down (Automatic operation) | Below 1 V |
| H3-4 (AUTO) - H3-1 (GND) | R - LA | Power window motor AUTO DOWN input | Power switch on (IG), driver door power window fully open | 11 to 14 V |
| H3-5 (LED) - H3-1 (GND) | W - LA | LED illumination signal | Power switch on (IG) | 11 to 14 V |
| H3-5 (LED) - H3-1 (GND) | W - LA | LED illumination signal | Approximately 43 seconds after power switch turned off | Below 1 V |
| H3-7 (DOWN) - H3-1 (GND) | R - LA | Power window motor DOWN input | Power switch on (IG), driver door power window regulator switch not pushed or pulled | 11 to 14 V |
| H3-7 (DOWN) - H3-1 (GND) | R - LA | Power window motor DOWN input | Power switch on (IG), driver door power window regulator switch pushed halfway down (Manual operation) | Below 1 V |
| H3-7 (DOWN) - H3-1 (GND) | R - LA | Power window motor DOWN input | Power switch on (IG), driver door power window fully closed | 11 to 14 V |
| H3-7 (DOWN) - H3-1 (GND) | R - LA | Power window motor DOWN input | Power switch on (IG), driver door power window regulator switch fully pushed down (Automatic position) | Below 1 V |
| H3-7 (DOWN) - H3-1 (GND) | R - LA | Power window motor DOWN input | Power switch on (IG), driver door power window fully open | 11 to 14 V |
| H3-10 (UP) - H3-1 (GND) | G - LA | Power window motor UP input | Power switch on (IG), driver door power window regulator switch not pushed or pulled | 11 to 14 V |
| H3-10 (UP) - H3-1 (GND) | G - LA | Power window motor UP input | Power switch on (IG), driver door power window regulator switch pulled halfway up (Manual operation) | Below 1 V |
| H3-10 (UP) - H3-1 (GND) | G - LA | Power window motor UP input | Power switch on (IG), driver door power window fully open | 11 to 14 V |
| H3-10 (UP) - H3-1 (GND) | G - LA | Power window motor UP input | Power switch on (IG), driver door power window regulator switch fully pulled up (Automatic operation) | Below 1 V |
| H3-10 (UP) - H3-1 (GND) | G - LA | Power window motor UP input | Power switch on (IG), driver door power window fully closed | 11 to 14 V |
CHECK INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY AND MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU)
| *A | Main Body ECU (Multiplex Network Body ECU) with 1 Connector | *B | for LHD |
| *C | for RHD | - | - |
| *1 | Main Body ECU (Multiplex Network Body ECU) | - | - |
| *A | Main Body ECU (Multiplex Network Body ECU) with 2 Connectors | *B | for LHD |
| *C | for RHD | - | - |
| *1 | Main Body ECU (Multiplex Network Body ECU) | - | - |
Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU>REMOVAL
Reconnect the instrument panel junction block assembly connectors.
Measure the voltage and resistance according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| MB-11 (GND1) - Body ground | - | Ground | Always | Below 1 Ω |
| MB-30 (BECU) - Body ground | - | Auxiliary battery power supply | Power switch off | 11 to 14 V |
| MB-29 (ACC) - Body ground | - | ACC power supply | Power switch on (ACC) | 11 to 14 V |
| MB-29 (ACC) - Body ground | - | ACC power supply | Power switch off | Below 1 V |
| MB-32 (IG) - Body ground | - | Power switch power supply | Power switch on (IG) | 11 to 14 V |
| MB-32 (IG) - Body ground | - | Power switch power supply | Power switch off | Below 1 V |
Install the main body ECU (multiplex network body ECU) to the instrument panel junction block assembly.
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU>INSTALLATION
Measure the voltage and check for pulses according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| G59-2 (KOFF) - Body ground | L - Body ground | Power window relay operation signal | Power switch on (IG) | 11 to 14 V |
| G59-2 (KOFF) - Body ground | L - Body ground | Power window relay operation signal | Approximately 43 seconds after power switch turned off | Below 1 V |
| 3D-36 (FLCY) - Body ground | R - Body ground | Front door courtesy switch LH input | Front door LH open | Below 1 V |
| 3D-36 (FLCY) - Body ground | R - Body ground | Front door courtesy switch LH input | Front door LH closed | Pulse generation |
| G59-19 (FRCY) - Body ground | R - Body ground | Front door courtesy switch RH input | Front door RH open | Below 1 V |
| G59-19 (FRCY) - Body ground | R - Body ground | Front door courtesy switch RH input | Front door RH closed | Pulse generation |