The HV battery uses nickel metal-hydride batteries and does not require external charging. The hybrid vehicle control ECU controls the SOC (state of charge) of the HV battery at a constant level during driving. The HV battery is composed of 20 modules, and each module consists of six 1.2 V cells in series. The battery smart unit monitors battery block voltage at 10 locations. Each battery block is composed of 2 modules in a set.
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| P0A80 | 123 | Difference in voltage between battery blocks is larger than the standard (2 trip detection) | ·
HV battery ·
Battery smart unit |
P0A80-123 will not be set unless the vehicle is driven for approximately 10 minutes after clearing the DTC. (As 2 trip detection logic is used, check for DTCs including pending DTCs.)
DTC P0A80-123 is stored when a malfunction is detected in the HV battery or battery smart unit. If the HV supply battery is malfunctioning, the malfunction may not be reproduced when the condition of the HV supply battery changes due to difference in driving load (amperage), battery SOC and battery temperature. Therefore, use the freeze frame data when performing a repair.
When the HV battery is malfunctioning:
- Voltage of 1 or a few battery blocks has dropped. (voltage difference from that of the next block is 1 V or more.)
- Voltage of all battery blocks is output randomly with no certain pattern.
When the battery smart unit is malfunctioning:
- Differences in battery block voltages have a certain pattern.
In order to ensure HV battery performance, appropriate cooling performance must be maintained. Perform the following items as necessary. If cooling performance has decreased and "MAINTENANCE REQUIRED FOR TRACTION BATTERY COOLING PARTS SEE OWNER'S MANUAL" is displayed on the multi-information display, make sure to perform the following items:
Make sure the air intake port is not blocked.
Clean the battery cooling blower filter.
Clear the DTCs to reset the learning values even if no DTCs are stored.
When disposing of an HV battery, make sure to return it through an authorized collection agent who is capable of handling it safely. If the HV battery is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.
A
B
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Read output DTCs.
Using the intelligent tester, make a note of the freeze frame data item "Battery Block Vol -V01 to V10".
Compare the freeze frame data item "Battery Block Vol -V01 to V10" values with those shown in the following combination tables.
| Circuit A Battery Block | Circuit B Battery Block | Condition |
|---|---|---|
| Battery Block Vol -V01 (VB1) | Battery Block Vol -V02 (VB2) | "Battery Block Vol -V01" - "Battery Block Vol -V02" = 0.3 V or more |
| Battery Block Vol -V04 (VB4) | Battery Block Vol -V03 (VB3) | "Battery Block Vol -V04" - "Battery Block Vol -V03" = 0.3 V or more |
| Battery Block Vol -V05 (VB5) | Battery Block Vol -V06 (VB6) | "Battery Block Vol -V05" - "Battery Block Vol -V06" = 0.3 V or more |
| Battery Block Vol -V08 (VB8) | Battery Block Vol -V07 (VB7) | "Battery Block Vol -V08" - "Battery Block Vol -V07" = 0.3 V or more |
| Battery Block Vol -V09 (VB9) | Battery Block Vol -V10 (VB10) | "Battery Block Vol -V09" - "Battery Block Vol -V10" = 0.3 V or more |
| Circuit A Battery Block | Circuit B Battery Block | Condition |
|---|---|---|
| Battery Block Vol -V01 (VB1) | Battery Block Vol -V02 (VB2) | "Battery Block Vol -V02" - "Battery Block Vol -V01" = 0.3 V or more |
| Battery Block Vol -V04 (VB4) | Battery Block Vol -V03 (VB3) | "Battery Block Vol -V03" - "Battery Block Vol -V04" = 0.3 V or more |
| Battery Block Vol -V05 (VB5) | Battery Block Vol -V06 (VB6) | "Battery Block Vol -V06" - "Battery Block Vol -V05" = 0.3 V or more |
| Battery Block Vol -V08 (VB8) | Battery Block Vol -V07 (VB7) | "Battery Block Vol -V07" - "Battery Block Vol -V08" = 0.3 V or more |
| Battery Block Vol -V09 (VB9) | Battery Block Vol -V10 (VB10) | "Battery Block Vol -V10" - "Battery Block Vol -V09" = 0.3 V or more |
When an internal malfunction occurs in the battery smart unit, this symptom (difference in voltage of 0.3 V or more for all 5 pairs of blocks) will occur.
| Result | Proceed to |
|---|---|
| All conditions in table 1 are met. | A |
| All conditions in table 2 are met. | |
| Other than above | B |
Turn the power switch off.
A
B