Home › Power Source / Network › 1NZ-FXE BATTERY / CHARGING › CHARGING SYSTEM › from 2017.06
RM2170E _57 Power Source / Network _057031 1NZ-FXE BATTERY / CHARGING _0278065 CHARGING SYSTEM G

1NZ-FXE BATTERY / CHARGING  CHARGING SYSTEM  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 1.CHECK AUXILIARY BATTERY

a.

Check that the auxiliary battery cables are connected to the correct terminals.

If they are not, connect them properly.


b.

Check the auxiliary battery for damage and deformation. If severe damage, deformation or leakage is found, replace the auxiliary battery.


c.

Check the electrolyte level in each cell.

·

If the electrolyte level is below the lower line, replace the auxiliary battery.



Hide 2.CHECK AUXILIARY BATTERY VOLTAGE

a.

Turn the ignition switch off and turn on the high beam headlights for 30 seconds. This will remove the surface charge from the auxiliary battery.


b.

Measure the battery voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
Positive (+) auxiliary battery terminal - Negative (-) auxiliary battery terminal Ignition switch off 20°C (68°F) 12.0 V or higher


If the voltage is not as specified, recharge or replace the battery.


Hide 3.RECHARGE AUXILIARY BATTERY

a.

Recharge the auxiliary battery.

HINT:
·

Recharge the auxiliary battery according to the charger's instructions.

·

Apply the appropriate charging current according to the type of auxiliary battery as shown in the table below.


Charge Method Charging Current
Normal Below 5 A
Quick Below 15 A



b.

Turn the ignition switch off and turn on the high beam headlights for 30 seconds. This will remove the surface charge from the auxiliary battery.


c.

Measure the battery voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
Positive (+) auxiliary battery terminal - Negative (-) auxiliary battery terminal Ignition switch off 20°C (68°F) 12.0 V or higher


If the voltage is not as specified, replace the battery.


Hide 4.CHECK AUXILIARY BATTERY TERMINAL, FUSIBLE LINK AND FUSE

a.

Check that the auxiliary battery terminals are not loose or corroded.

Torque:
Positive (+) Auxiliary Battery Terminal : 5.4 N*m (55 kgf*cm, 48 in.*lbf)
Negative (-) Auxiliary Battery Terminal : 5.4 N*m (55 kgf*cm, 48 in.*lbf)

If a terminal is loose or corroded, tighten or clean the terminal.


b.

Measure the resistance of each fusible link and fuse for the auxiliary battery charging system.

Standard Resistance:

Below 1 Ω


If any of the results are not as specified, replace the fusible link or fuse.


Hide 5.CHECK AMD TERMINAL

CAUTION:

Be sure to wear insulated gloves.


a.

Remove the service plug grip.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>SERVICE PLUG GRIP>REMOVAL

NOTICE:

After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Check that the AMD terminal is connected securely, and there is not a contact problem.

If there are any arc marks, replace the affected parts.


c.
A267465

Check that the nut for the AMD terminal are tightened to the specified torque.

Torque:
8.4 N*m (86 kgf*cm, 74 in.*lbf)

If there are no arc marks and the AMD terminal connection is faulty, connect the AMD terminal securely.



Hide 6.CHECK DC/DC CONVERTER FUNCTION

a.
A111747C13
0.802,0.979 1.146,0.646 1.146,0.646 1.281,0.646 false 1.177,1.26 0.896,1.656 0.896,1.656 0.75,1.656 false 1.302,0.563 1.49,0.719 0.188,0.156 10 *a 0.552,1.563 0.75,1.708 0.198,0.146 10 *b
*a Probe Direction
*b Current Flowing into Auxiliary Battery


Connect the AC/DC 400 A probe to the positive (+) auxiliary battery cable.


b.

Turn the ignition switch to ON (READY) and leave the vehicle as is until the electric current flowing to the auxiliary battery becomes 10 A or less.


c.

Turn on the high beam headlights, and turn the blower motor switch to the HI position and the rear window defogger on.


d.
A314451C01
0.729,0.854 0.865,0.417 0.865,0.417 1.083,0.417 false 0.719,1.76 0.938,1.76 0.938,1.76 1.229,1.313 false 1.135,0.333 1.448,0.49 0.313,0.156 10 false *a 0.563,1.688 0.875,1.844 0.313,0.156 10 false *b
*a Probe Direction
*b Current Flowing from Auxiliary Battery


Measure the current and voltage according to the value(s) in the table below.

Result:
Item Tester Connection Condition Specified Condition
Current flowing from auxiliary battery Positive (+) auxiliary battery cable Ignition switch ON (READY)
(The high beam headlights are on, the blower motor switch is in the HI position, and the rear window defogger is turned on.)
Below 0 A
(No current from auxiliary battery)
Auxiliary battery voltage Positive (+) auxiliary battery terminal - Negative (-) auxiliary battery terminal 13 to 15 V


If the result is not as specified, replace the inverter with converter assembly.