DATA LIST
Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
Turn the power switch off (lock).
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Chassis / EMPS / Data List.
According to the display on the GTS, read the "Data List".
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Meter Vehicle Velocity | Vehicle speed from meter/
Min.: 0.0 km/h (0.0mph) Max.: 300.0 km/h (186.4 mph) |
0 km/h (0 mph) | Power switch on (ready) and vehicle stopped |
| No significant fluctuation | Power switch on (ready) and vehicle driven at constant speed | ||
| Motor Actual Current | Current to motor/
Min.: -327.68 A Max.: 327.67 A |
Value changes in proportion to steering effort
-The value increases when turning right and decreases when turning left |
Power switch on (ready) and steering wheel being turned |
| Command Value Current | Requested current to motor/
Min.: -327.68 A Max.: 327.67 A |
Value changes in proportion to steering effort
-The value increases when turning right and decreases when turning left |
Power switch on (ready) and steering wheel being turned |
| Thermistor Temperature | ECU substrate temperature/
Min.: -50.0°C (-58.0°F) Max.: 150.0°C (302.0°F) |
-50 to 150°C (-58 to 302°F) | - |
| PIG Power Supply | Power source voltage to activate motor/
Min.: 0.0000 V Max.: 20.1531 V |
9 to 16 V | Always |
| IG Power Supply | ECU power source voltage/
Min.: 0.0000 V Max.: 20.1531 V |
9 to 16 V | Power switch on (IG) |
| Steering Wheel Torque | Steering wheel torque/
Min.: -327.68 Nm Max.: 7.00 Nm |
Value changes in proportion to steering effort | Power switch on (ready) and steering wheel being turned |
| Torque Sensor 1 Output | Torque sensor 1 output value/
Min.: 0.0000 V Max.: 4.9725 V |
2.3 to 2.7 V | Power switch on (ready) and steering wheel not being turned (without load) |
| 2.5 to 3.8 V | Power switch on (ready) and steering wheel being turned to right with vehicle stopped | ||
| 1.2 to 2.5 V | Power switch on (ready) and steering wheel being turned to left with vehicle stopped | ||
| Torque Sensor 2 Output | Torque sensor 2 output value/
Min.: 0.0000 V Max.: 4.9725 V |
2.3 to 2.7 V | Power switch on (ready) and steering wheel not being turned (without load) |
| 1.2 to 2.5 V | Power switch on (ready) and steering wheel being turned to right with vehicle stopped | ||
| 2.5 to 3.8 V | Power switch on (ready) and steering wheel being turned to left with vehicle stopped | ||
| TRQ1 Zero Point Value | Zero point value of torque sensor 1/
Min.: 0.0000 V Max.: 4.9725 V |
2.3 to 2.7 V | Power switch on (ready) and steering wheel not being turned (without load) |
| TRQ2 Zero Point Value | Zero point value of torque sensor 2/
Min.: 0.0000 V Max.: 4.9725 V |
2.3 to 2.7 V | Power switch on (ready) and steering wheel not being turned (without load) |
| Motor Terminal Volt(+) | Motor terminal M1 voltage/
Min.: 0.0 V Max.: 25.5 V |
9 to 16 V | Power switch on (ready) and steering wheel being turned to right |
| 6 to 8 V | Power switch on (ready) and steering wheel being turned to left | ||
| Motor Terminal Volt(-) | Motor terminal M2 voltage/
Min.: 0.0 V Max.: 25.5 V |
6 to 8 V | Power switch on (ready) and steering wheel being turned to right |
| 9 to 16 V | Power switch on (ready) and steering wheel turned to left | ||
| IG ON/OFF Times | Number of times of power switch ON/OFF after fail detection/
Min.: 0 time Max.: 65535 times |
- | This value indicates the number of times of IG ON/OFF after the latest DTC detection. |
| Motor Overheat Record | Continuous overheat prevention control record/
Unrec or Rec |
Unrec | - |
| Motor Lo Power Record | PIG power source voltage drop record/
Unrec or Rec |
Unrec | - |
| Eng Rev Inter Record | Record of power switch on (IG) signal interruption/
Unrec or Rec |
Unrec | - |
| Spd Sig Invalid Record | Vehicle speed signal invalid record/
Unrec or Rec |
Unrec | - |
| Battery Voltage Lo Record | Auxiliary battery voltage reduction history/
Min.: 0 times, Max.: 65535 times |
0 to 65535 | - |
| Ready Status | Ready status/
READY or OFF |
READY or OFF | - |
| Motor Overheat Limit Cnt(Normal) | Number of times that assist limit was performed according to the estimated temperature of the portion where heat was generated in the power steering ECU assembly and motor coil/
Min.: 0 times Max.: 255 times |
- | - |
| Assist Limit Cnt(Power Voltage Low) | Number of times that assist limit was performed due to auxiliary battery voltage having dropped to 9 V or below/
Min.: 0 times Max.: 255 times |
- | - |
| Power Vol Low Prevention Limit Cnt | Number of times that assist limit was performed due to auxiliary battery voltage having dropped to 9.7 V or below/
Min.: 0 times Max.: 255 times |
- | - |
| Eng Stall/Ready OFF Cnt | Number of times that assist limit was performed after the engine stalled and the power switch was turned off/
Min.: 0 times Max.: 255 times |
- | - |
| Motor Overheat Limit Cnt(Motor Overload) | Number of times that assist limit was performed to prevent the system from overheating in a case where the motor is overloaded because it is locked due to the steering wheel being turned to the full lock position or a tire hitting a curb/
Min.: 0 times Max.: 255 times |
- | - |
| Assist Limit Cnt(Vehicle Spd Sig Malf) | Number of times that assist power was set to a value suitable for high-speed driving when driving at high speeds due to an abnormal vehicle speed signal/
Min.: 0 times Max.: 255 times |
- | - |
| Assist Limit Record 1 | Information of assist limit that was used in the past or is currently in use (latest history)/
Unrec, Mtr Overheat, Pow Vol Low, Pow Vol Low Prevent, Eng Stall, Ready OFF, Mtr Overload, Vhcl Spd Sig Malf, Batt Vol Keep |
- | - |
| Record 1 Key Cycle | Number of times that the power switch was turned on (IG) before Assist Limit Record 1 was stored/
Min.: 0 times Max.: 65535 times |
- | - |
| Record 1 Key Cycle Elapsed Time | Period of time that elapsed after the power switch was turned on (IG) before Assist Limit Record 1 was stored/
Min.: 0.0 s Max.: 53687091.1 s |
- | - |
| Assist Limit Record 2 | Information of assist limit that was used in the past (second latest history)/
Unrec, Mtr Overheat, Pow Vol Low, Pow Vol Low Prevent, Eng Stall, Ready OFF, Mtr Overload, Vhcl Spd Sig Malf, Batt Vol Keep |
- | - |
| Record 2 Key Cycle | Number of times that the power switch was turned on (IG) after Assist Limit Record 2 was stored before Assist Limit Record 1 was stored/
Min.: 0 times Max.: 65535 times |
- | - |
| Record 2 Key Cycle Elapsed Time | Period of time that elapsed after the power switch was turned on (IG) before Assist Limit Record 2 was stored/
Min.: 0.0 s Max.: 53687091.1 s |
- | - |
| Assist Limit Record 3 | Information of assist limit that was used in the past (third latest history)/
Unrec, Mtr Overheat, Pow Vol Low, Pow Vol Low Prevent, Eng Stall, Ready OFF, Mtr Overload, Vhcl Spd Sig Malf, Batt Vol Keep |
- | - |
| Record 3 Key Cycle | Number of times that the power switch was turned on (IG) after Assist Limit Record 3 was stored before Assist Limit Record 2 was stored/
Min.: 0 times Max.: 65535 times |
- | - |
| Record 3 Key Cycle Elapsed Time | Period of time that elapsed after the power switch was turned on (IG) before Assist Limit Record 3 was stored/
Min.: 0.0 s Max.: 53687091.1 s |
- | - |
| Current Key Cycle | Number of current trip/
Min.: 0 times Max.: 65535 times |
- | - |
| Current Key Cycle Elapsed Time | Time elapsed since the power switch was turned on (IG)/
Min.: 0.0 s Max.: 53687091.1 s |
- | - |
| Steering Angle | Steering angle/
Min.: -3072.0 deg Max.: 3070.5 deg |
- | - |
| The Number of DTCs | Number of detected DTCs when freeze frame data stored/
Min.: 0 Max.: 255 |
0 to 255 | - |