Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID BATTERY SYSTEM › from 2018.08
RM2170E _51 Engine / Hybrid System _057004 HYBRID / BATTERY CONTROL _0277925 HYBRID BATTERY SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID BATTERY SYSTEM  P0A85-123  Hybrid Battery Pack Cooling Fan 1 Control Circuit High  P0A85-345  Hybrid Battery Pack Cooling Fan 1 Control Circuit High  


DESCRIPTION

Refer to the circuit description for DTC P0A84-123 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>P0A84-123).

DTC No. INF Code DTC Detection Condition Trouble Area
PP0A85 123 w/o Canister Pump Module:
When the speed calculated based on the battery cooling blower assembly frequency is out of the target control speed range (1 trip detection)
·

Battery cooling blower assembly

·

Battery smart unit


w/ Canister Pump Module:
Both of the following conditions are met:
·

The speed calculated based on the battery cooling blower assembly output frequency is not within the target control speed range.

·

The battery cooling blower assembly speed is excessively high when a speed below a certain level is requested.


(2 trip detection logic)
·

Battery cooling blower assembly

·

Battery smart unit


PP0A85 345 w/ Canister Pump Module:
Both of the following conditions are met:
·

The HV battery temperature is high and the hybrid battery cooling fan speed calculated based on the battery cooling blower assembly output frequency is not within the target control speed range.

·

The HV battery temperature is high and the battery cooling blower assembly speed is excessively high when a speed below a certain level is requested.


(1 trip detection logic)
·

Battery cooling blower assembly

·

Battery smart unit



Related Data List
DTC No. Data List
P0A85-123
·

Cooling Fan 0

·

Cooling Fan Mode 1

·

Cooling Fan Frequency 1


P0A85-345

The following items can be helpful when performing repairs:

Data List
·

Temp of Batt TB1 to 3

·

+B


HINT:
·

"Cooling Fan Frequency 1" is detected when the battery cooling blower assembly is operating and its value changes in proportion to the battery cooling blower assembly rotation speed.

·

If the battery cooling blower assembly speed is too high, this DTC is stored.



WIRING DIAGRAM

Refer to the wiring diagram for DTC P0A84-123 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>P0A84-123).

CAUTION / NOTICE / HINT

CAUTION:
·

Before inspecting the high-voltage system, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·

After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>PRECAUTION).

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.


·

When disposing of an HV battery, make sure to return it through an authorized collection agent who is capable of handling it safely. If the HV battery is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.



NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).


HINT:

After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.

1.

Connect the GTS to the DLC3.

2.

Turn the power switch on (IG) and turn the GTS on.

3.

Enter the following menus: Powertrain / Hybrid Control / Active Test / Driving the Battery Cooling Fan.

4.

Select fan mode 6 and operate the battery cooling blower assembly and wait for 60 seconds or more.

HINT:

Operation of the battery cooling blower assembly can be confirmed by checking if air is sucked into the air intake port of the intake duct.