Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM › 2014.11–2016.05
RM2070E _51 Engine / Hybrid System _061906 HYBRID / BATTERY CONTROL _0301573 HYBRID CONTROL SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  P0A08-264  DC / DC Converter Status Circuit  


DESCRIPTION

The DC/DC converter converts the DC 201.6 V of the HV battery into DC 12 V in order to supply power to areas such as the vehicle's lighting, audio, and ECU systems. In addition, it charges the auxiliary battery. A transistor bridge circuit initially converts DC 201.6 V into alternating current, and a transformer lowers the voltage. Then, it is rectified and smoothed (into direct current) and converted into DC 12 V. The DC/DC converter controls the output voltage in order to keep a constant voltage at the terminals of the auxiliary battery.

The power management control ECU sends a signal to the DC/DC converter to prohibit its control and receives signals indicating a normal or abnormal condition of the 12 V charging system via the NODD signal line.

If the DC/DC converter malfunctions, the vehicle will become inoperative. Therefore, the power management control ECU monitors the operation of the DC/DC converter and detects malfunctions.

A217225E33
1,0.927 1.479,1.146 0.479,0.219 10 false DC/DC 0.885,2.24 1.531,2.448 0.646,0.208 10 false DC/DC-S 0.927,2.563 1.448,2.792 0.521,0.229 10 false MAIN 1.625,0.656 1.99,0.865 0.365,0.208 10 false AMD 1.021,3.052 1.667,3.49 0.646,0.438 10 false Auxiliary Battery 2.844,4.458 5.271,4.729 2.427,0.271 10 false Power Management Control ECU 1.979,3.438 4.094,3.729 2.115,0.292 10 false Inverter with Converter Assembly 2.26,2.417 3.917,2.688 1.656,0.271 10 false Hybrid Vehicle Converter 3.906,2.177 4.146,2.385 0.24,0.208 10 false S 4.115,2.167 4.563,2.375 0.448,0.208 10 false NODD 4.604,2.156 5.031,2.354 0.427,0.198 10 false VLO 5.396,2.177 5.802,2.396 0.406,0.219 10 false IGCT 6.375,2.51 7.042,2.979 0.667,0.469 10 false from IGCT Relay 5.292,0.313 6.052,0.552 0.76,0.24 10 false DC201.6V 4.99,2.167 5.323,2.365 0.333,0.198 10 false IDH* 4.906,3.896 7.156,4.135 2.25,0.24 10 false Air Conditioning Amplifier Assembly 0.146,4.563 1.646,4.76 1.5,0.198 10 false *: w/ PTC Heater

DTC No. INF Code DTC Detection Condition Trouble Area
P0A08 264 DC/DC converter malfunction and the auxiliary battery voltage drops to 11 V or less with the power switch on (READY).
·

Wire harness or connector

·

Inverter cooling system

·

Hybrid vehicle transaxle assembly

·

Generator cable

·

Motor cable

·

Frame wire

·

Inverter with converter assembly

·

Fusible link block assembly (MAIN)

·

Fuse (DC/DC-S)

·

Fusible link block assembly (DC/DC)

·

Power management control ECU



Related Data List
DTC No. INF Code Data List Item
P0A08 264
·

+B

·

Inverter Coolant Water Temperature

·

Short Wave Highest Val



*: If the inverter is overheating, control may be suspended for self-protection of the DC/DC converter and this DTC may be stored.

HINT:
·

When the NODD signal line is open, DC/DC converter control is prohibited and the auxiliary battery voltage will be approximately 12 V (or less).

·

Regarding NODD signal circuit, when the transistor of the power management control ECU turns on, a signal is sent to the inverter to prohibit DC/DC converter control. Sends a malfunction signal to the power management control ECU when the inverter side transistor is on.



WIRING DIAGRAM

A262679E12
2.24,4.813 4.406,5.219 2.167,0.406 10 false Power Management Control ECU 0.604,4.021 1.698,4.229 1.094,0.208 10 false Auxiliary Battery 5.76,4.802 7.021,5.49 1.26,0.688 10 false Inverter with Converter Assembly 2.875,2.385 3.313,2.563 0.438,0.177 10 false IGCT 1.917,1.813 2.344,1.99 0.427,0.177 10 false IGCT 1.844,1.333 2.344,1.51 0.5,0.177 10 false DC/DC 1.813,0.875 2.552,1.052 0.74,0.177 10 false DC/DC-S 0.521,3.115 0.906,3.292 0.385,0.177 10 false MAIN 3.583,1.813 4.354,1.99 0.771,0.177 10 false IGCT NO. 2 3.938,3.01 4.406,3.188 0.469,0.177 10 false MREL 3.938,3.375 4.375,3.552 0.438,0.177 10 false NODD 4.167,4.333 4.417,4.51 0.25,0.177 10 false E1 6.021,3.385 6.521,3.563 0.5,0.177 10 false NODD 6.01,0.719 6.396,0.896 0.385,0.177 10 false S 6.021,1.198 6.406,1.375 0.385,0.177 10 false AMD 6.021,1.656 6.438,1.833 0.417,0.177 10 false IGCT 5.646,0.719 6.01,0.896 0.365,0.177 10 false A59 5.646,1.677 5.969,1.854 0.323,0.177 10 false A59 5.646,3.469 5.938,3.646 0.292,0.177 10 false A59 4.438,3.01 4.708,3.188 0.271,0.177 10 false A22 4.438,3.479 4.75,3.656 0.313,0.177 10 false A21 4.49,4.438 4.698,4.615 0.208,0.177 10 false L5 3.458,3.677 3.917,3.854 0.458,0.177 10 false 100 Ω 2.885,3.729 3.344,3.906 0.458,0.177 10 false 47 kΩ 2.885,4.198 3.344,4.375 0.458,0.177 10 false 82 kΩ 4.458,1.177 4.719,1.354 0.26,0.177 10 false 1F 4.146,1.552 4.344,1.729 0.198,0.177 10 false 2 3.677,1.563 3.875,1.74 0.198,0.177 10 false 1 2.583,2.063 2.781,2.24 0.198,0.177 10 false 2 3.396,2.042 3.594,2.219 0.198,0.177 10 false 1 3.396,1.583 3.594,1.76 0.198,0.177 10 false 5 2.583,1.583 2.781,1.76 0.198,0.177 10 false 3 2.281,1.552 2.479,1.729 0.198,0.177 10 false 2 1.802,1.542 2,1.719 0.198,0.177 10 false 1 2.281,0.594 2.479,0.771 0.198,0.177 10 false 2 1.802,0.594 2,0.771 0.198,0.177 10 false 1 4.51,4.24 4.719,4.448 0.208,0.208 10 false 6 4.479,3.281 4.792,3.458 0.313,0.177 10 false 21 4.5,2.802 4.615,2.979 0.115,0.177 10 false 6 5.688,3.281 5.958,3.458 0.271,0.177 10 false 12 5.698,0.521 5.896,0.698 0.198,0.177 10 false 11 5.719,1.49 5.823,1.667 0.104,0.177 10 false 1 4.5,1 4.594,1.177 0.094,0.177 10 false 1 0.813,1.188 1.073,1.365 0.26,0.177 10 false 1E 0.844,0.99 0.938,1.167 0.094,0.177 10 false 1 0.979,2.594 4.5,2.938 3.521,0.344 10 false Engine Room Relay Block and Junction Block Assembly

CAUTION / NOTICE / HINT

CAUTION:
·

Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·

After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals of the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION).

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.




NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).


HINT:
·

After repair, clear the DTCs, turn the power switch off and wait for 30 seconds or more and perform the following procedure to confirm that the auxiliary battery low voltage indicated by this DTC has been repaired.

(a)

Wait for 2 minutes with the park (P) selected, the power switch on (READY) and the following conditions met, then confirm that Data List item "+B" is between 13.0 and 15.0 V.

(If charging is not performed and the electrical load increases, +B voltage may not be steady and gradually drops.)

(1)

Headlight switch is in the HI position.

(2)

A/C blower fan switch is in the HI position.

(3)

Window defogger switch is turned on.

If the DC/DC converter has an internal malfunction, DTC P0A08-264 is stored regardless of the auxiliary battery voltage after performing this procedure.

If the auxiliary battery voltage drops, the power switch turns off regardless of DTCs being stored or not.




·

By performing the following procedure, the DC/DC converter function can be checked.

(a)

Connect the AC/DC 400 A probe to the positive auxiliary battery cable.

(1)

Turn the power switch on (READY) and leave the vehicle as it is until the electric current flowing into the auxiliary battery becomes 10 A or less.

(2)

Turn the power switch on (READY) and the headlight switch and A/C blower fan switch in the HI position, and the window defogger turned on.

(3)

Confirm that the current drawn from the auxiliary battery is 0 A or lower and the auxiliary battery voltage is between 13.0 and 15.0 V.




·

This DTC is stored when a part other than the DC/DC converter is malfunctioning or depending on user operation.

Malfunction cases to store DTC P0A08-264
Malfunction Case Remarks Inspection Step
Fuse is blown. (DCDC-S, DC/DC) - 2, 3
The connector between the auxiliary battery and DC/DC converter is not connected securely. - 24, 25, 26
High-voltage insulation between the inverter, generator (MG1), motor (MG2) and body ground is poor (body ground). DTC P0AA6 may be stored if the ground potential fluctuates due to a high-voltage insulation malfunction. 1
A signal connector of the power management control ECU or inverter is not connected securely. - 4, 5
The DC/DC converter is malfunctioning. Inspect the DC/DC converter function. 11
Control is suspended due to overheating. (The inverter water pump assembly is malfunctioning, the coolant is not sufficient, a hose is clogged, etc.) When the inverter is overheating, the DC/DC converter has self protection control that suspends the DC/DC converter control. As that time, this DTC may be stored.
The suspended DC/DC converter control will return to normal by clearing the DTCs and turning the power switch off.
12 to 15, 19


·

If this vehicle is used to jump start another vehicle with a discharged battery, a fuse may blow due to overcurrent or the DC/DC converter self-protection may be activated. Also, if this vehicle is jump started by a vehicle with a 24 V battery, the same malfunction may occur and this DTC may be stored. (The suspended DC/DC converter control will return to normal by clearing the DTCs and turning the power switch off.)


·

If the DC/DC converter is malfunctioning, the auxiliary battery cannot be charged. Therefore, once the power switch is turned off, it may be impossible to turn it on (READY) again if the auxiliary battery is completely discharged. In this case, charge the auxiliary battery. Be careful as charging is not performed during the inspection.

·

If the power switch turns off immediately after it is turned on (READY), the auxiliary battery voltage may be low. Charge the auxiliary battery.



PROCEDURE

1.CHECK DTC OUTPUT (HYBRID CONTROL)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.


d.

Check if DTCs are output.

Result:
Result Proceed to
P0A08-264 only is output. A
Any of the following DTCs including pending DTCs are also output. B


DTC No. Relevant Diagnosis
P0A93-346 Inverter Cooling System Performance
P0A94-547, 548, 549 DC / DC Converter Performance
P0AA6-526, 613 Hybrid Battery Voltage System Isolation Fault
P0ADB-227 Hybrid Battery Positive Contactor Control Circuit Low
P0ADF-229 Hybrid Battery Negative Contactor Control Circuit Low
P0AE6-225 Hybrid Battery Precharge Contactor Control Circuit Low
P0C73-776 Motor Electronics Coolant Pump "A" Control Performance
P3004-131, 803 High Voltage Power Resource
P314A-828 Inverter Coolant Pump Speed Signal


e.

Turn the power switch off.



A

2.CHECK FUSE (DC/DC-S)

B

2.CHECK FUSE (DC/DC-S)
a.
A270232E05
1.854,1.427 2.948,1.729 false 0.177,0.146 0.458,0.344 0.281,0.198 10 false *1 2.979,1.646 3.26,1.844 0.281,0.198 10 false *2

Remove the DC/DC-S fuse from the engine room relay block and junction block assembly.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
DC/DC-S fuse terminals Always Below 1 Ω


Text in Illustration
*1 Engine Room Relay Block and Junction Block Assembly
*2 DC/DC-S Fuse


c.

Install the DC/DC-S fuse.



OK

3.CHECK FUSIBLE LINK (DC/DC)

NG

24.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - DC/DC-S FUSE)
3.CHECK FUSIBLE LINK (DC/DC)
a.
U154316E02
1.615,0.25 1.885,0.417 0.271,0.167 10 false 1E 0.792,0.229 0.99,0.396 0.198,0.167 10 false 1F

Disconnect connector 1E from the engine room relay block and junction block assembly.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1F-1 (AMD) - 1E-1 Always Below 1 Ω



c.

Check the fusible links (DC/DC) in the engine room relay block and junction block assembly for improper installation.

OK:

The fusible link is installed securely.



d.

Connect the engine room relay block and junction block assembly connector.



OK

4.CHECK CONNECTOR CONNECTION CONDITION (POWER MANAGEMENT CONTROL ECU CONNECTOR)

NG

REPLACE FUSIBLE LINK BLOCK ASSEMBLY (FUSIBLE LINK(DC/DC))

4.CHECK CONNECTOR CONNECTION CONDITION (POWER MANAGEMENT CONTROL ECU CONNECTOR)

OK

5.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

NG

CONNECT SECURELY

5.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

OK

6.CHECK CABLE AND WIRE HARNESS

NG

CONNECT SECURELY

6.CHECK CABLE AND WIRE HARNESS
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.
A209686

Remove the inverter cover from the inverter with converter assembly.


c.
U190581E02
1.208,0.573 0.823,0.604 false 2.094,0.396 2.469,0.354 false 2.021,0.458 2.333,0.51 false 1.938,0.531 2.229,0.698 false 1.813,0.719 2.177,0.875 false 1.729,0.802 2.063,1.052 false 1.656,0.875 1.948,1.229 false 0.625,0.552 0.792,0.74 0.167,0.188 10 true *1 0.719,0.073 0.885,0.26 0.167,0.188 10 true *2 2.51,0.271 2.656,0.458 0.146,0.188 10 true V 2.396,0.448 2.563,0.688 0.167,0.24 10 false U 2.271,0.656 2.469,0.865 0.198,0.208 10 false W 2.198,0.854 2.406,1.083 0.208,0.229 10 false V 2.083,1.031 2.271,1.229 0.188,0.198 10 false U 1.948,1.24 2.167,1.49 0.219,0.25 10 true W 0.813,0.344 0.969,0.51 0.156,0.167 10 true f1 1.156,0.083 1.365,0.24 0.208,0.156 10 true e1

Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.

NOTICE:

Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.


Standard Resistance:
Tester Connection Condition Specified Condition
f1-1 (W) - Body ground and shield ground Power switch off 1 MΩ or higher
f1-2 (U) - Body ground and shield ground Power switch off 1 MΩ or higher
f1-3 (V) - Body ground and shield ground Power switch off 1 MΩ or higher
e1-1 (W) - Body ground and shield ground Power switch off 1 MΩ or higher
e1-2 (U) - Body ground and shield ground Power switch off 1 MΩ or higher
e1-3 (V) - Body ground and shield ground Power switch off 1 MΩ or higher


Text in Illustration
*1 Generator Cable
*2 Motor Cable

HINT:

Perform this inspection while the generator cable and motor cable are connected.



d.

Install the inverter cover to the inverter with converter assembly.



OK

7.CHECK ENGINE ROOM RELAY BLOCK AND JUNCTION BLOCK ASSEMBLY (AMD TERMINAL CONNECTION CONDITION)

NG

16.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG1)
7.CHECK ENGINE ROOM RELAY BLOCK AND JUNCTION BLOCK ASSEMBLY (AMD TERMINAL CONNECTION CONDITION)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.
A216630

Check that the bolt for the AMD terminal is tightened to the specified torque, the AMD terminal is connected securely, and there is no contact problem.

Torque:

T=8.0 N*m (82 kgf*cm, 71 in.*lbf)


Result:
Result Proceed to
There are no arc marks. The terminal is connected securely and there is no contact problem. A
There are no arc marks. The terminal is not connected securely and there is a contact problem. B
There are arc marks. - C




A

8.CHECK TERMINAL VOLTAGE (AMD TERMINAL VOLTAGE)

B

CONNECT SECURELY

C

REPLACE MALFUNCTIONING PARTS

8.CHECK TERMINAL VOLTAGE (AMD TERMINAL VOLTAGE)
CAUTION:

Be sure to wear insulated gloves.


a.

Connect the cable to the negative (-) auxiliary battery terminal.


b.
U154319E02
1.552,0.323 1.823,0.49 0.271,0.167 10 false 1F

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
1F-1 (AMD) - Body ground Power switch off Same as auxiliary battery voltage




OK

9.CHECK HARNESS AND CONNECTOR (ENGINE ROOM RELAY BLOCK AND JUNCTION BLOCK ASSEMBLY - INVERTER WITH CONVERTER ASSEMBLY)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

9.CHECK HARNESS AND CONNECTOR (ENGINE ROOM RELAY BLOCK AND JUNCTION BLOCK ASSEMBLY - INVERTER WITH CONVERTER ASSEMBLY)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect the A59 inverter with converter assembly connector.


c.

Connect the cable to the negative (-) auxiliary battery terminal.


d.
U190557E02
1.156,0.917 1.656,0.313 false 1.521,1.771 1.146,1.031 false 1.708,0.198 2.104,0.385 0.396,0.188 10 false IGCT 1.542,1.771 1.802,1.958 0.26,0.188 10 false S 0.146,0.094 0.458,0.281 0.313,0.188 10 false *a 0.406,1.052 0.677,1.219 0.271,0.167 10 false A59

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
A59-11 (S) - Body ground Always Same as auxiliary battery voltage


Text in Illustration
*a Front view of wire harness connector
(to Inverter with Converter Assembly)


e.

Disconnect the cable from the negative (-) auxiliary battery terminal.


f.

Reconnect the A59 inverter with converter assembly connector.



OK

10.CHECK POWER MANAGEMENT CONTROL ECU (RESISTANCE VALUE OF NODD)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

10.CHECK POWER MANAGEMENT CONTROL ECU (RESISTANCE VALUE OF NODD)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect the A59 inverter with converter assembly.


c.
U154303E07
1.26,1.031 0.677,1.26 false 0.104,0 0.292,0.167 0.188,0.167 10 false *a 0.135,1.198 0.625,1.354 0.49,0.156 10 false NODD 1.573,1.76 1.833,1.938 0.26,0.177 10 false A59

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A59-12 (NODD) - Body ground Power switch off 110 to 150 kΩ


Text in Illustration
*a Front view of wire harness connector
(to Inverter with Converter Assembly)


d.

Reconnect the A59 inverter with converter assembly connector.



OK

11.CHECK DC/DC CONVERTER FUNCTION

NG

18.INSPECT POWER MANAGEMENT CONTROL ECU (RESISTANCE VALUE OF NODD)
11.CHECK DC/DC CONVERTER FUNCTION
HINT:

The current at the AMD terminal cannot be measured directly because of space limitations. Measure the current flowing at the auxiliary battery instead.


a.

Connect the AC/DC 400 A probe to the positive auxiliary battery line.


b.

Install the service plug grip.


c.

Connect the cable to the negative (-) auxiliary battery terminal.


d.

Turn the power switch on (READY) and leave the vehicle as it is until the electric current flowing into the auxiliary battery becomes 10 A or less.

HINT:

If the power switch turns off immediately after it is turned on (READY), auxiliary battery voltage may be low. Recharge the auxiliary battery and perform this procedure again.



e.
A174427E02
0.978,0.503 1.569,0.844 0.591,0.341 10 Probe Direction 0.165,1.637 1.163,2.145 0.998,0.508 10 Current Flowing into Auxiliary Battery 0.652,0.955 0.835,0.583 0.835,0.583 0.95,0.583 false

A174428E02
0.996,0.355 1.587,0.696 0.591,0.341 10 Probe Direction 0.182,1.489 1.180,1.997 0.998,0.508 10 Current Flowing from Auxiliary Battery 0.669,0.807 0.852,0.435 0.852,0.435 0.967,0.435 false

Measure the current flowing from the auxiliary battery with the power switch on (READY), the headlight position switch and blower motor switch in the HI position, and the rear window defogger turned on.

Standard Current:
Item Condition Specified Condition
Current flowing from auxiliary battery Power switch on (READY)
(The headlight position switch and blower motor switch are in the HI position, and the rear window defogger is turned on.)
0 A or less
(no current from auxiliary battery)



f.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Item Condition Specified Condition
Auxiliary battery voltage Power switch on (READY)
(The headlight position switch and blower motor switch are in the HI position, and the rear window defogger is turned on.)
13 to 15 V



g.

Turn the power switch off.



OK

12.CHECK QUANTITY OF HV COOLANT

NG

REFER TO REPLACE INVERTER WITH CONVERTER ASSEMBLY PARTS

12.CHECK QUANTITY OF HV COOLANT

A

13.CHECK COOLANT HOSE

B

ADD HV COOLANT

C

CHECK FOR COOLANT LEAK AND ADD COOLANT

13.CHECK COOLANT HOSE

OK

14.PERFORM ACTIVE TEST USING GTS (CONTROL THE ELECTRIC COOLING FAN)

NG

CORRECT THE PROBLEM

14.PERFORM ACTIVE TEST USING GTS (CONTROL THE ELECTRIC COOLING FAN)

OK

15.CHECK HV COOLANT (CHECK FOR CONDITIONS THAT MAY HAVE CAUSED FREEZING)

NG

15.CHECK HV COOLANT (CHECK FOR CONDITIONS THAT MAY HAVE CAUSED FREEZING)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Read the freeze frame data Ambient Temperature using the GTS.


d.

Check if the freeze frame data Ambient Temperature is below freezing.

Result:
Result Proceed to
Ambient Temperature value is above freezing temperature of the HV coolant A
Ambient Temperature value is below freezing temperature of the HV coolant B


HINT:
·

HV coolant (SLLC) with a 30% concentration freezes at -15 °C (5°F) and HV coolant (SLLC) with a 50% concentration freezes at -35°C (-31°F).

·

If the HV coolant freezes in the HV radiator or HV water pump, the coolant temperature in the inverter with converter assembly rises because the HV coolant cannot circulate. As a result, a DTC may be set.

·

A DTC is set when the water pump impeller cannot rotate due to freezing of the HV coolant.

·

If a DTC is set due to freezing of HV coolant, the problem cannot be reproduced. Judge whether freezing of HV coolant occurred according to the freeze point of the HV coolant, HV coolant change history and ambient temperature when the DTC was set.




e.

Turn the power switch off.



A

REFER TO REPLACE INVERTER WITH CONVERTER ASSEMBLY PARTS

B

19.REPLACE HV COOLANT
16.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG1)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.
A209686

Remove the inverter cover from the inverter with converter assembly.


c.
A215643E13
1.25,0.573 0.844,0.198 false 0.667,0.073 0.865,0.281 0.198,0.208 10 false *1

Disconnect the generator cable from the inverter with converter assembly.

Text in Illustration
*1 Generator Cable


d.
U190550E02
0.938,0.99 0.583,0.99 false 1.333,1.781 1.208,1.948 false 1.729,1.813 1.729,1.938 false 2.135,1.792 2.281,1.958 false 0.094,0.073 0.302,0.302 0.208,0.229 10 false *1 0.396,0.917 0.604,1.146 0.208,0.229 10 false *2 1.115,1.969 1.323,2.135 0.208,0.167 10 false W 1.688,1.979 1.833,2.135 0.146,0.156 10 false U 2.271,1.958 2.479,2.125 0.208,0.167 10 false V 2.823,1.094 3.01,1.271 0.188,0.177 10 false f1

Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.

NOTICE:

Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.


Standard Resistance:
Tester Connection Condition Specified Condition
f1-1 (W) - Body ground and shield ground Power switch off 100 MΩ or higher
f1-2 (U) - Body ground and shield ground Power switch off 100 MΩ or higher
f1-3 (V) - Body ground and shield ground Power switch off 100 MΩ or higher


Text in Illustration
*1 Generator Cable
*2 Shield Ground


e.

Connect the generator cable to the inverter with converter assembly.


f.

Install the inverter cover to the inverter with converter assembly.



OK

17.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG2)

NG

20.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (GENERATOR CABLE CONNECTION CONDITION)
17.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG2)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.
A209686

Remove the inverter cover from the inverter with converter assembly.


c.
A352279E01
1.552,0.385 1.042,0.135 false 0.875,0.052 1.188,0.25 0.313,0.198 10 false *1

Disconnect the motor cable from the inverter with converter assembly.

Text in Illustration
*1 Motor Cable


d.
U190553E02
0.958,0.99 0.615,1 false 1.354,1.771 1.229,1.969 false 1.729,1.781 1.729,1.969 false 2.125,1.781 2.229,1.979 false 0.094,0.083 0.271,0.26 0.177,0.177 10 false *1 0.406,0.938 0.583,1.115 0.177,0.177 10 false *2 1.135,1.979 1.313,2.156 0.177,0.177 10 false W 1.698,1.979 1.885,2.156 0.188,0.177 10 false U 2.208,1.99 2.385,2.167 0.177,0.177 10 false V 2.823,1.042 3.094,1.208 0.271,0.167 10 false e1

Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.

NOTICE:

Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.


Standard Resistance:
Tester Connection Condition Specified Condition
e1-1 (W) - Body ground and shield ground Power switch off 100 MΩ or higher
e1-2 (U) - Body ground and shield ground Power switch off 100 MΩ or higher
e1-3 (V) - Body ground and shield ground Power switch off 100 MΩ or higher


Text in Illustration
*1 Motor Cable
*2 Shield Ground


e.

Connect the motor cable to the inverter with converter assembly.


f.

Install the inverter cover to the inverter with converter assembly.



OK

REFER TO REPLACE INVERTER WITH CONVERTER ASSEMBLY PARTS

NG

22.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MOTOR CABLE CONNECTION CONDITION)
18.INSPECT POWER MANAGEMENT CONTROL ECU (RESISTANCE VALUE OF NODD)
a.
U154234E03
0.875,1.969 1.104,2.406 true 1.833,1.833 2.073,2.396 true 0.677,1.167 0.948,1.333 0.271,0.167 10 false A21 1.969,1.167 2.24,1.333 0.271,0.167 10 false L5 0.177,0.229 0.365,0.417 0.188,0.188 10 false *a 0.854,2.427 1.292,2.615 0.438,0.188 10 false NODD 2.052,2.417 2.24,2.604 0.188,0.188 10 false E1

Disconnect all the connectors from the power management control ECU.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A21-21 (NODD) - L5-6 (E1) Power switch off 110 to 150 kΩ


Text in Illustration
*a Component without harness connected
(Power Management Control ECU)


c.

Reconnect the power management control ECU connectors.



OK

REPAIR OR REPLACE HARNESS OR CONNECTOR

NG

20.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (GENERATOR CABLE CONNECTION CONDITION)

A

21.CHECK GENERATOR CABLE

B

REPLACE MALFUNCTIONING PARTS

C

CONNECT SECURELY

22.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MOTOR CABLE CONNECTION CONDITION)

A

23.CHECK MOTOR CABLE

B

REPLACE MALFUNCTIONING PARTS

C

CONNECT SECURELY

24.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - DC/DC-S FUSE)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect the A59 inverter with converter assembly connector.


c.
A270232E05
1.854,1.427 2.948,1.729 false 0.177,0.146 0.458,0.344 0.281,0.198 10 false *1 2.979,1.646 3.26,1.844 0.281,0.198 10 false *2

Remove the DC/DC-S fuse from the engine room relay block and junction block assembly.

Text in Illustration
*1 Engine Room Relay Block and Junction Block Assembly
*2 DC/DC-S Fuse


d.

Measure the resistance according to the value(s) in the table below.

U190718E01
0.97,0.193 1.178,0.377 0.208,0.184 10 *a 3.912,0.193 4.120,0.377 0.208,0.184 10 *1 6.392,0.81 6.600,0.993 0.208,0.184 10 *2 0.662,1.608 0.811,1.792 0.149,0.184 10 S 1.342,1.436 0.771,1.668 false 1.696,2.068 1.968,2.224 0.272,0.156 10 A59

Text in Illustration
*1 Engine Room Relay Block and Junction Block Assembly *2 DC/DC-S Fuse
*a Front view of wire harness connector
(to Inverter with Converter Assembly)
- -

Standard Resistance:
Tester Connection Condition Specified Condition
A59-11 (S) or 2 (DC/DC-S fuse) - Body ground and other terminals Power switch off 10 kΩ or higher



e.

Install the DC/DC-S fuse.


f.

Reconnect the A59 inverter with converter assembly connector.



OK

25.REFER TO REPLACE INVERTER WITH CONVERTER ASSEMBLY PARTS

NG

26.REPAIR OR REPLACE HARNESS OR CONNECTOR
25.REFER TO REPLACE INVERTER WITH CONVERTER ASSEMBLY PARTS
a.

Refer to replace inverter with converter assembly parts (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DTC CHECK / CLEAR).



NEXT

REPLACE FUSE (DC/DC-S)

26.REPAIR OR REPLACE HARNESS OR CONNECTOR

NEXT

REPLACE FUSE (DC/DC-S)