The DC/DC converter converts the DC 201.6 V of the HV battery into DC 12 V in order to supply power to areas such as the vehicle's lighting, audio, and ECU systems. In addition, it charges the auxiliary battery. A transistor bridge circuit initially converts DC 201.6 V into alternating current, and a transformer lowers the voltage. Then, it is rectified and smoothed (into direct current) and converted into DC 12 V. The DC/DC converter controls the output voltage in order to keep a constant voltage at the terminals of the auxiliary battery.
The power management control ECU sends a signal to the DC/DC converter to prohibit its control and receives signals indicating a normal or abnormal condition of the 12 V charging system via the NODD signal line.
If the DC/DC converter malfunctions, the vehicle will become inoperative. Therefore, the power management control ECU monitors the operation of the DC/DC converter and detects malfunctions.
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| P0A08 | 264 | DC/DC converter malfunction or the auxiliary battery voltage drops to 11 V or less with the power switch on (READY). | ·
Wire harness or connector ·
Inverter cooling system ·
Hybrid vehicle transaxle assembly ·
Generator cable ·
Motor cable ·
Frame wire ·
Inverter with converter assembly ·
Fusible link block assembly (MAIN) ·
Fuse (DC/DC-S, IGCT, IGCT NO. 2) ·
Fusible link block assembly (DC/DC) ·
Power management control ECU |
| DTC No. | INF Code | Data List Item |
|---|---|---|
| P0A08 | 264 | ·
+B ·
Inverter Coolant Water Temperature ·
Short Wave Highest Val |
When the NODD signal line is open, DC/DC converter control is prohibited and the auxiliary battery voltage will be approximately 12 V (or less).
Regarding NODD signal circuit, when the transistor of the power management control ECU turns on, a signal is sent to the inverter to prohibit DC/DC converter control. Sends a malfunction signal to the power management control ECU when the inverter side transistor is on.
Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals of the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION).
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).
After repair, clear the DTCs, turn the power switch off and wait for 30 seconds or more and perform the following procedure to confirm that the auxiliary battery low voltage indicated by this DTC has been repaired.
Wait for 2 minutes with the park (P) selected, the power switch on (READY) and the following conditions met, then confirm that Data List item "+B" is between 13.0 and 15.0 V.
(If charging is not performed and the electrical load increases, +B voltage may not be steady and gradually drops.)
Headlight switch is in the HI position.
A/C blower fan switch is in the HI position.
Window defogger switch is turned on.
If the DC/DC converter has an internal malfunction, DTC P0A08-264 is stored regardless of the auxiliary battery voltage after performing this procedure.
If the auxiliary battery voltage drops, the power switch turns off regardless of DTCs being stored or not.
By performing the following procedure, the DC/DC converter function can be checked.
Connect the AC/DC 400 A probe to the positive auxiliary battery cable.
Turn the power switch on (READY) and leave the vehicle as it is until the electric current flowing into the auxiliary battery becomes 10 A or less.
Turn the power switch on (READY) and the headlight switch and A/C blower fan switch in the HI position, and the window defogger turned on.
Confirm that the current drawn from the auxiliary battery is 0 A or lower and the auxiliary battery voltage is between 13.0 and 15.0 V.
This DTC is stored when the power switch is on (READY) and the auxiliary battery voltage is 11 V or less. Therefore, this DTC may be also stored when a part other than the DC/DC converter is malfunctioning or depending on user operation.
| Malfunction Case | Remarks | Inspection Step |
|---|---|---|
| Fuse is blown. (DCDC-S, DC/DC) | - | 2, 3 |
| The connector between the auxiliary battery and DC/DC converter is not connected securely. | - | 24, 25, 26 |
| High-voltage insulation between the inverter, generator (MG1), motor (MG2) and body ground is poor (body ground). | DTC P0AA6 may be stored if the ground potential fluctuates due to a high-voltage insulation malfunction. | 1 |
| A signal connector of the power management control ECU or inverter is not connected securely. | - | 4, 5 |
| The DC/DC converter is malfunctioning. | Inspect the DC/DC converter function. | 11 |
| Control is suspended due to overheating. (The inverter water pump assembly is malfunctioning, the coolant is not sufficient, a hose is clogged, etc.) | When the inverter is overheating, the DC/DC converter has self protection control that suspends the DC/DC converter control. As that time, this DTC may be stored.
The suspended DC/DC converter control will return to normal by clearing the DTCs and turning the power switch off. |
12 to 15, 19 |
If this vehicle is used to jump start another vehicle with a discharged battery, a fuse may blow due to overcurrent or the DC/DC converter self-protection may be activated. Also, if this vehicle is jump started by a vehicle with a 24 V battery, the same malfunction may occur and this DTC may be stored. (The suspended DC/DC converter control will return to normal by clearing the DTCs and turning the power switch off.)
If the DC/DC converter is malfunctioning, the auxiliary battery cannot be charged. Therefore, once the power switch is turned off, it may be impossible to turn it on (READY) again if the auxiliary battery is completely discharged. In this case, charge the auxiliary battery. Be careful as charging is not performed during the inspection.
If the power switch turns off immediately after it is turned on (READY), the auxiliary battery voltage may be low. Charge the auxiliary battery.
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | Proceed to |
|---|---|
| P0A08-264 only is output. | A |
| Any of the following DTCs including pending DTCs are also output. | B |
| DTC No. | Relevant Diagnosis |
|---|---|
| P0A93-346 | Inverter Cooling System Performance |
| P0A94-547, 548, 549 | DC / DC Converter Performance |
| P0AA6-526, 613 | Hybrid Battery Voltage System Isolation Fault |
| P0ADB-227 | Hybrid Battery Positive Contactor Control Circuit Low |
| P0ADF-229 | Hybrid Battery Negative Contactor Control Circuit Low |
| P0AE6-225 | Hybrid Battery Precharge Contactor Control Circuit Low |
| P0C73-776 | Motor Electronics Coolant Pump "A" Control Performance |
| P3004-131, 803 | High Voltage Power Resource |
| P314A-828 | Inverter Coolant Pump Speed Signal |
Turn the power switch off.
A
B
(See pageEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART)
Remove the DC/DC-S fuse from the engine room relay block and junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| DC/DC-S fuse terminals | Always | Below 1 Ω |
| *1 | Engine Room Relay Block and Junction Block Assembly |
| *2 | DC/DC-S Fuse |
Install the DC/DC-S fuse.
OK
NG
Disconnect connector 1E from the engine room relay block and junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1F-1 (AMD) - 1E-1 | Always | Below 1 Ω |
Check the fusible links (DC/DC) in the engine room relay block and junction block assembly for improper installation.
The fusible link is installed securely.
Connect the engine room relay block and junction block assembly connector.
OK
NG
OK
NG
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the inverter cover from the inverter with converter assembly.
Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| f1-1 (W) - Body ground and shield ground | Power switch off | 1 MΩ or higher |
| f1-2 (U) - Body ground and shield ground | Power switch off | 1 MΩ or higher |
| f1-3 (V) - Body ground and shield ground | Power switch off | 1 MΩ or higher |
| e1-1 (W) - Body ground and shield ground | Power switch off | 1 MΩ or higher |
| e1-2 (U) - Body ground and shield ground | Power switch off | 1 MΩ or higher |
| e1-3 (V) - Body ground and shield ground | Power switch off | 1 MΩ or higher |
| *1 | Generator Cable |
| *2 | Motor Cable |
Perform this inspection while the generator cable and motor cable are connected.
Install the inverter cover to the inverter with converter assembly.
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Check that the bolt for the AMD terminal is tightened to the specified torque, the AMD terminal is connected securely, and there is no contact problem.
T=8.0 N*m (82 kgf*cm, 71 in.*lbf)
| Result | Proceed to | |
|---|---|---|
| There are no arc marks. | The terminal is connected securely and there is no contact problem. | A |
| There are no arc marks. | The terminal is not connected securely and there is a contact problem. | B |
| There are arc marks. | - | C |
A
B
C
Be sure to wear insulated gloves.
Connect the cable to the negative (-) auxiliary battery terminal.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1F-1 (AMD) - Body ground | Power switch off | Same as auxiliary battery voltage |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A59 inverter with converter assembly connector.
Connect the cable to the negative (-) auxiliary battery terminal.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A59-11 (S) - Body ground | Always | Same as auxiliary battery voltage |
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A59-1 (IGCT) - Body ground | Power switch on (IG) | Same as auxiliary battery voltage |
Turning the power switch on (IG) with the inverter with converter assembly connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Reconnect the A59 inverter with converter assembly connector.
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A59 inverter with converter assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A59-12 (NODD) - Body ground | Power switch off | 110 to 150 kΩ |
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
Reconnect the A59 inverter with converter assembly connector.
OK
NG
The current at the AMD terminal cannot be measured directly because of space limitations. Measure the current flowing at the auxiliary battery instead.
Connect the AC/DC 400 A probe to the positive auxiliary battery line.
Install the service plug grip.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (READY) and leave the vehicle as it is until the electric current flowing into the auxiliary battery becomes 10 A or less.
If the power switch turns off immediately after it is turned on (READY), auxiliary battery voltage may be low. Recharge the auxiliary battery and perform this procedure again.
Measure the current flowing from the auxiliary battery with the power switch on (READY), the headlight position switch and blower motor switch in the HI position, and the rear window defogger turned on.
| Item | Condition | Specified Condition |
|---|---|---|
| Current flowing from auxiliary battery | Power switch on (READY)
(The headlight position switch and blower motor switch are in the HI position, and the rear window defogger is turned on.) |
0 A or less
(no current from auxiliary battery) |
Measure the voltage according to the value(s) in the table below.
| Item | Condition | Specified Condition |
|---|---|---|
| Auxiliary battery voltage | Power switch on (READY)
(The headlight position switch and blower motor switch are in the HI position, and the rear window defogger is turned on.) |
13 to 15 V |
Turn the power switch off.
OK
NG
A
B
C
OK
NG
OK
NG
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Read the freeze frame data Ambient Temperature using the GTS.
Check if the freeze frame data Ambient Temperature is below freezing.
| Result | Proceed to |
|---|---|
| Ambient Temperature value is above freezing temperature of the HV coolant | A |
| Ambient Temperature value is below freezing temperature of the HV coolant | B |
HV coolant (SLLC) with a 30% concentration freezes at -15 °C (5°F) and HV coolant (SLLC) with a 50% concentration freezes at -35°C (-31°F).
If the HV coolant freezes in the HV radiator or HV water pump, the coolant temperature in the inverter with converter assembly rises because the HV coolant cannot circulate. As a result, a DTC may be set.
A DTC is set when the water pump impeller cannot rotate due to freezing of the HV coolant.
If a DTC is set due to freezing of HV coolant, the problem cannot be reproduced. Judge whether freezing of HV coolant occurred according to the freeze point of the HV coolant, HV coolant change history and ambient temperature when the DTC was set.
Turn the power switch off.
A
B
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the inverter cover from the inverter with converter assembly.
Disconnect the generator cable from the inverter with converter assembly.
| *1 | Generator Cable |
Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| f1-1 (W) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| f1-2 (U) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| f1-3 (V) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| *1 | Generator Cable |
| *2 | Shield Ground |
Connect the generator cable to the inverter with converter assembly.
Install the inverter cover to the inverter with converter assembly.
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the inverter cover from the inverter with converter assembly.
Disconnect the motor cable from the inverter with converter assembly.
| *1 | Motor Cable |
Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| e1-1 (W) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| e1-2 (U) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| e1-3 (V) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| *1 | Motor Cable |
| *2 | Shield Ground |
Connect the motor cable to the inverter with converter assembly.
Install the inverter cover to the inverter with converter assembly.
OK
NG
Disconnect all the connectors from the power management control ECU.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A21-21 (NODD) - L5-6 (E1) | Power switch off | 110 to 150 kΩ |
| *a | Component without harness connected
(Power Management Control ECU) |
Reconnect the power management control ECU connectors.
OK
NG
NEXT
A
B
C
OK
NG
A
B
C
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A59 inverter with converter assembly connector.
Remove the DC/DC-S fuse from the engine room relay block and junction block assembly.
| *1 | Engine Room Relay Block and Junction Block Assembly |
| *2 | DC/DC-S Fuse |
Measure the resistance according to the value(s) in the table below.
| *1 | Engine Room Relay Block and Junction Block Assembly | *2 | DC/DC-S Fuse |
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A59-11 (S) or 2 (DC/DC-S fuse) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
Install the DC/DC-S fuse.
Reconnect the A59 inverter with converter assembly connector.
OK
NG
Refer to replace inverter with converter assembly parts (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DTC CHECK / CLEAR).
NEXT
NEXT