HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  P0AE7-224  Hybrid Battery Precharge Contactor Control Circuit High  


DESCRIPTION

Refer to the description for DTC P0AE6-225 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0AE6-225).

DTC No. INF Code DTC Detection Condition Trouble Area
P0AE7 224 Open or +B short in SMRP circuit
·

Wire harness or connector

·

Hybrid battery junction block assembly

·

Power management control ECU



WIRING DIAGRAM

Refer to the wiring diagram for DTC P0AE6-225 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0AE6-225).

CAUTION / NOTICE / HINT

CAUTION:
·

Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·

After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION).

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.




NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).


HINT:
·

If P0AE7-224 is stored, the vehicle cannot be started.

·

After the repair, clear the DTCs, perform the following procedure and check that the same DTC (including pending DTC) is not output.

(a)

Turn the power switch off and wait for 30 seconds or more.

(b)

Turn the power switch on (READY) and wait for 30 seconds or more.

(c)

Turn the power switch off and wait for 60 seconds or more.




PROCEDURE

1.READ VALUE USING GTS (SMRP STATUS)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / Data List / SMRP Status.


d.

Read the Data List.

OK:
Tester Display Condition Specified Condition
SMRP Status Power switch on (IG) OFF



e.

Turn the power switch off.



OK

2.CHECK CONNECTOR CONNECTION CONDITION (POWER MANAGEMENT CONTROL ECU CONNECTOR)

NG

4.CHECK HARNESS AND CONNECTOR (SMRP VOLTAGE)
2.CHECK CONNECTOR CONNECTION CONDITION (POWER MANAGEMENT CONTROL ECU CONNECTOR)

OK

3.CHECK CONNECTOR CONNECTION CONDITION (HYBRID BATTERY JUNCTION BLOCK ASSEMBLY CONNECTOR)

NG

CONNECT SECURELY

3.CHECK CONNECTOR CONNECTION CONDITION (HYBRID BATTERY JUNCTION BLOCK ASSEMBLY CONNECTOR)

OK

NG

CONNECT SECURELY

4.CHECK HARNESS AND CONNECTOR (SMRP VOLTAGE)
a.

Turn the power switch on (IG).


b.
U154407E03
2.094,1.698 2.604,2.469 false 1.979,1.021 2.188,1.188 0.208,0.167 10 false L5 0.135,0.208 0.406,0.375 0.271,0.167 10 false *a 2.396,2.479 2.896,2.646 0.5,0.167 10 false SMRP

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
L5-3 (SMRP) - Body ground Power switch on (IG) Below 1 V


Text in Illustration
*a Component with harness connected
(Power Management Control ECU)


c.

Turn the power switch off.



OK

5.CHECK CONNECTOR CONNECTION CONDITION (POWER MANAGEMENT CONTROL ECU CONNECTOR)

NG

6.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - BODY GROUND)
5.CHECK CONNECTOR CONNECTION CONDITION (POWER MANAGEMENT CONTROL ECU CONNECTOR)

OK

NG

CONNECT SECURELY

6.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - BODY GROUND)
a.

Disconnect the L5 power management control ECU connector.


b.
U154249E03
2.104,2.365 1.667,2.427 true 2.75,2.281 3.104,2.458 0.354,0.177 10 false L5 1.219,2.354 1.656,2.531 0.438,0.177 10 false SMRP 0.146,0.083 0.302,0.26 0.156,0.177 10 false *a

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
L5-3 (SMRP) - Body ground Power switch off 112 to 274 Ω


Text in Illustration
*a Rear view of wire harness connector
(to Power Management Control ECU)


c.

Reconnect the L5 power management control ECU connector.



OK

7.CHECK HARNESS AND CONNECTOR (SHORT TO POWER SUPPLY WIRES)

NG

8.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - HYBRID BATTERY JUNCTION BLOCK ASSEMBLY)
7.CHECK HARNESS AND CONNECTOR (SHORT TO POWER SUPPLY WIRES)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.
A238663E04
0.135,0.169 0.402,0.362 0.267,0.193 10 *1 2.913,0.771 3.180,0.963 0.267,0.193 10 *2 2.919,1.659 3.186,1.852 0.267,0.193 10 *3 1.779,1.266 2.876,0.877 false 2.215,1.971 2.899,1.773 false

Remove the IGCT NO. 2 and AM2 fuses from the engine room relay block and junction block assembly.

Text in Illustration
*1 Engine Room Relay Block and Junction Block Assembly
*2 AM2 Fuse
*3 IGCT NO. 2 Fuse


c.

Remove the No. 2 hybrid battery shield sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV RELAY ASSEMBLY>REMOVAL).


d.

Disconnect the c6 hybrid battery junction block assembly connector.


e.

Disconnect the A21, A22, L5 and L6 power management control ECU connectors.


f.
U154392E01
0.418,1.441 0.682,1.622 0.264,0.181 10 A21 0.472,2.809 0.740,2.990 0.268,0.181 10 +B2 0.026,3.101 0.394,3.241 0.369,0.140 10 FCTL 0.958,2.809 1.226,2.990 0.268,0.181 10 +B1 0.187,0.146 0.343,0.328 0.156,0.181 10 *a 1.174,1.447 1.438,1.628 0.264,0.181 10 A22 0.702,2.114 0.649,2.802 false 0.054,2.809 0.220,2.990 0.166,0.181 10 GI 0.407,2.182 0.169,2.809 false 0.572,2.114 0.249,3.096 false 1.25,2.124 1.115,2.795 false 2.213,2.124 2.122,2.809 false 1.43,2.809 1.672,2.990 0.242,0.181 10 IG2 1.596,2.124 1.575,2.809 false 0.536,3.101 0.945,3.248 0.409,0.146 10 MREL 1.19,2.124 0.792,3.1 false 2.028,2.187 1.775,3.101 false 3.072,2.114 2.895,3.101 false 1.099,3.101 1.451,3.241 0.351,0.140 10 IG2D 1.529,2.124 1.301,3.092 false 2.056,1.448 2.262,1.629 0.206,0.181 10 L5 2.824,1.431 3.022,1.612 0.198,0.181 10 L6 2.179,3.101 2.561,3.241 0.382,0.140 10 AM22 2.688,3.101 3.033,3.241 0.346,0.140 10 IG1D 2.436,2.833 2.817,2.972 0.380,0.139 10 AM21 2.342,2.123 2.405,3.106 false 3.139,2.113 3.184,2.825 false 2.726,2.115 2.684,2.828 false 1.557,3.101 1.904,3.243 0.348,0.142 10 SPDI 1.87,2.809 2.291,2.951 0.421,0.142 10 SMRP 2.941,2.833 3.361,2.975 0.420,0.142 10 ACCD

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
L5-3 (SMRP) - A21-2 (+B2) Power switch off 10 kΩ or higher
L5-3 (SMRP) - A22-5 (+B1) Power switch off 10 kΩ or higher
L5-3 (SMRP) - L5-1 (AM22) Power switch off 10 kΩ or higher
L5-3 (SMRP) - L6-7 (AM21) Power switch off 10 kΩ or higher
L5-3 (SMRP) - A22-6 (MREL) Power switch off 10 kΩ or higher
L5-3 (SMRP) - A22-1 (IG2) Power switch off 10 kΩ or higher
L5-3 (SMRP) - L6-1 (ACCD) Power switch off 10 kΩ or higher
L5-3 (SMRP) - L6-2 (IG1D) Power switch off 10 kΩ or higher
L5-3 (SMRP) - A22-2 (IG2D) Power switch off 10 kΩ or higher
L5-3 (SMRP) - L5-14 (SPDI) Power switch off 10 kΩ or higher
L5-3 (SMRP) - A21-16 (GI) Power switch off 10 kΩ or higher
L5-3 (SMRP) - A21-4 (FCTL) Power switch off 10 kΩ or higher


Text in Illustration
*a Rear view of wire harness connector
(to Power Management Control ECU)


g.

Reconnect the A21, A22, L5 and L6 power management control ECU connectors.


h.

Reconnect the c6 hybrid battery junction block assembly connector.


i.

Install the No. 2 hybrid battery shield sub-assembly.


j.

Install the IGCT NO. 2 and AM2 fuses.



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

8.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - HYBRID BATTERY JUNCTION BLOCK ASSEMBLY)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the No. 2 hybrid battery shield sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV RELAY ASSEMBLY>REMOVAL).


c.

Disconnect the c6 hybrid battery junction block assembly connector.


d.

Disconnect the L5 power management control ECU connector.


e.

Measure the resistance according to the value(s) in the table below.

A317802E13
2.917,1.667 3.271,1.917 0.354,0.25 5.792,1.854 6.135,2.104 0.344,0.25 1.875,1.698 2.385,1.698 false 4.927,2.24 5.208,2.042 false 0.115,0.115 0.542,0.385 0.427,0.271 10 false *a 3.823,0.156 4.25,0.427 0.427,0.271 10 false *b 3.021,1.719 3.448,1.99 0.427,0.271 10 false L5 5.885,1.896 6.313,2.167 0.427,0.271 10 false c6 1.438,1.615 1.927,1.885 0.49,0.271 10 false SMRP 4.5,2.198 4.99,2.469 0.49,0.271 10 false SMRP

Standard Resistance (Check for Open):
Tester Connection Condition Specified Condition
L5-3 (SMRP) - c6-3 (SMRP) Power switch off Below 1 Ω


Standard Resistance (Check for Short):
Tester Connection Condition Specified Condition
L5-3 (SMRP) and c6-3 (SMRP) - Body ground and other terminals Power switch off 10 kΩ or higher


Text in Illustration
*a Rear view of wire harness connector
(to Power Management Control ECU)
*b Rear view of wire harness connector
(to Hybrid Battery Junction Block Assembly)


f.

Reconnect the L5 power management control ECU connector.


g.

Reconnect the c6 hybrid battery junction block assembly connector.


h.

Install the No. 2 hybrid battery shield sub-assembly.



OK

9.CHECK HARNESS AND CONNECTOR (HYBRID BATTERY JUNCTION BLOCK ASSEMBLY - BODY GROUND)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

9.CHECK HARNESS AND CONNECTOR (HYBRID BATTERY JUNCTION BLOCK ASSEMBLY - BODY GROUND)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the No. 2 hybrid battery shield sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV RELAY ASSEMBLY>REMOVAL).


c.

Disconnect the c6 hybrid battery junction block assembly connector.


d.
U190524E01
1.835,2.214 2.076,2.396 0.241,0.181 10 c6 1.294,2.456 1.886,2.738 false 1.911,2.668 2.245,2.817 0.334,0.149 10 GND 0.082,0.043 0.351,0.246 0.269,0.203 10 *a

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
c6-2 (GND) - Body ground Power switch off Below 1 Ω


Text in Illustration
*a Rear view of wire harness connector
(to Hybrid Battery Junction Block Assembly)


e.

Reconnect the c6 hybrid battery junction block assembly connector.


f.

Install the No. 2 hybrid battery shield sub-assembly.



OK

10.INSPECT HYBRID BATTERY JUNCTION BLOCK ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

10.INSPECT HYBRID BATTERY JUNCTION BLOCK ASSEMBLY
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the hybrid battery junction block assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV RELAY ASSEMBLY>COMPONENTS).


c.
U190681E02
0.092,0.085 0.317,0.283 0.225,0.198 10 *a 2.099,2.997 2.437,3.140 0.338,0.143 10 GND 1.477,2.997 1.921,3.140 0.444,0.143 10 SMRP 2.119,2.726 2.242,2.978 false 1.827,2.726 1.73,2.979 false 0.933,2.39 1.159,2.588 0.225,0.198 10 c6

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
c6-3 (SMRP) - c6-2 (GND) -40 to 80 °C (-40 to 176°F) 112 to 274 Ω


Text in Illustration
*a Component without harness connected
(Hybrid Battery Junction Block Assembly)


d.

Install the hybrid battery junction block assembly.



OK

NG