Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID BATTERY SYSTEM › from 2016.05
RM2070E _51 Engine / Hybrid System _061906 HYBRID / BATTERY CONTROL _0301574 HYBRID BATTERY SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID BATTERY SYSTEM  P0A85-123  Hybrid Battery Pack Cooling Fan 1 Control Circuit High  


DESCRIPTION

Refer to the circuit description for DTC P0A84-123 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>P0A84-123).

DTC No. INF Code DTC Detection Condition Trouble Area
P0A85 123 When the output voltage of the battery cooling blower assembly (VM) is too high compared to the target control voltage range* (1 trip detection)
·

Wire harness or connector

·

Battery cooling blower assembly

·

Battery smart unit

·

HV battery



HINT:

*: This DTC is stored when the battery cooling blower assembly is operating. When reproducing the DTC Detection Conditions, perform the Active Test "Driving the Battery Cooling Fan" to operate the battery cooling blower assembly.


WIRING DIAGRAM

Refer to the wiring diagram for DTC P0A84-123 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>P0A84-123).

Refer to the wiring diagram for DTC P0A9C-123 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>P0A9C-123).

CAUTION / NOTICE / HINT

CAUTION:
·

Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·

After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>PRECAUTION).

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.


·

When disposing of an HV battery, make sure to return it through an authorized collection agent who is capable of handling it safely. If the HV battery is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.

·

Before returning the HV battery, make sure to perform a recovery inspection (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>RECOVERY INSPECTION)

·

Make a note of the output DTCs as some of them may be necessary for recovery inspection of the HV battery.



NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).


PROCEDURE

1.CHECK FOR DTCS (HV)

A

2.CHECK HARNESS AND CONNECTOR (VOLTAGE)

B

2.CHECK HARNESS AND CONNECTOR (VOLTAGE)
a.

Remove the front seat assembly RH.



b.

Turn over the front floor carpet.


c.

Connect the GTS to the DLC3.


d.

Turn the power switch on (IG).


e.

Enter the following menus: Powertrain / Hybrid Control / Active Test / Driving the Battery Cooling Fan.


f.

Select each air volume mode (1 to 6) in the "Driving the Battery Cooling Fan" Active Test to operate the battery cooling blower assembly.

NOTICE:

If the Active Test cannot be performed, skip it and proceed to the next step to check voltage. In accordance with fail-safe system operation, the hybrid vehicle control ECU sends a command to operate the battery cooling fan.



g.
U190646E02
2.781,0.365 2.021,1.177 true 2.792,0.771 2.031,1.333 true 0.177,0.104 0.344,0.26 0.167,0.156 10 false *a 1.448,0.688 1.615,0.844 0.167,0.156 10 false *b 2.823,0.25 3.125,0.406 0.302,0.156 10 false VM0 2.823,0.625 3.229,0.781 0.406,0.156 10 false GND0 0.354,1.865 0.635,2.021 0.281,0.156 10 false S30

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
S30-2 (VM0) - S30-4 (GND0) Battery cooling blower is operating Below 5 V


Text in Illustration
*a Component with harness connected
(Battery Cooling Blower Assembly)
*b Front view of wire harness connector
(to Battery Cooling Blower Assembly)


HINT:

Measure the voltage on the wire side of the connector that is part of the battery cooling blower.


h.

Turn the power switch off.


i.

Install the front floor carpet.


j.

Install the front seat assembly RH.



OK

3.CHECK HARNESS AND CONNECTOR (BATTERY COOLING BLOWER - BATTERY SMART UNIT)

NG

6.CHECK HARNESS AND CONNECTOR (VOLTAGE)
3.CHECK HARNESS AND CONNECTOR (BATTERY COOLING BLOWER - BATTERY SMART UNIT)

OK

4.CHECK HV BATTERY (BATTERY TEMPERATURE SENSOR AND INLET AIR TEMPERATURE SENSOR)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

4.CHECK HV BATTERY (BATTERY TEMPERATURE SENSOR AND INLET AIR TEMPERATURE SENSOR)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the No. 1 hybrid battery shield sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>REMOVAL).


c.
U190664E02
2.125,0.865 2.396,1.021 0.271,0.156 10 false z24

Disconnect the z24 battery smart unit connector.


d.

Connect the cable to the negative (-) auxiliary battery terminal.


e.

Turn the power switch on (IG).


f.
U190651E02
2.344,2.26 2.625,2.229 true 2.229,2.24 2.552,1.896 true 2.125,2.24 2.208,1.969 true 2,2.24 1.969,1.75 true 1.896,2.24 1.583,1.74 true 1.792,2.24 1.25,1.75 true 1.479,2.229 0.896,1.781 true 1.385,2.24 0.854,1.958 true 1.479,2.396 0.948,2.781 true 1.375,2.385 0.781,2.615 true 1.896,2.396 1.458,2.906 true 1.781,2.396 1.177,2.885 true 2.01,2.396 2.156,2.917 true 2.125,2.396 2.438,2.875 true 2.229,2.396 2.542,2.708 true 2.344,2.385 2.656,2.552 true 0.677,2.729 1,2.917 0.323,0.188 10 false TC0 0.521,2.552 0.844,2.74 0.323,0.188 10 false TC1 0.583,1.677 0.938,1.865 0.354,0.188 10 false GC0 0.552,1.875 0.906,2.063 0.354,0.188 10 false GC1 0.198,0.094 0.365,0.25 0.167,0.156 10 false *a 2.375,2.885 2.677,3.073 0.302,0.188 10 false TB2 2.031,2.948 2.333,3.135 0.302,0.188 10 false TB3 1.281,2.917 1.583,3.104 0.302,0.188 10 false TB4 0.958,2.896 1.26,3.083 0.302,0.188 10 false TB5 2.552,2.698 2.854,2.885 0.302,0.188 10 false TB1 2.677,2.49 3.031,2.677 0.354,0.188 10 false TB0 2.656,2.135 2.979,2.323 0.323,0.188 10 false GB0 2.583,1.781 2.885,1.969 0.302,0.188 10 false GB1 2.042,1.76 2.344,1.948 0.302,0.188 10 false GB2 1.771,1.552 2.073,1.74 0.302,0.188 10 false GB3 1.385,1.583 1.688,1.771 0.302,0.188 10 false GB4 0.99,1.594 1.292,1.781 0.302,0.188 10 false GB5 0.698,2.302 0.938,2.49 0.24,0.188 10 false z24

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
z24-13 (TB0) - Body ground Power switch on (IG) 1 V or less
z24-1 (GB0) - Body ground Power switch on (IG) 1 V or less
z24-14 (TB1) - Body ground Power switch on (IG) 1 V or less
z24-2 (GB1) - Body ground Power switch on (IG) 1 V or less
z24-15 (TB2) - Body ground Power switch on (IG) 1 V or less
z24-3 (GB2) - Body ground Power switch on (IG) 1 V or less
z24-16 (TB3) - Body ground Power switch on (IG) 1 V or less
z24-4 (GB3) - Body ground Power switch on (IG) 1 V or less
z24-17 (TB4) - Body ground Power switch on (IG) 1 V or less
z24-5 (GB4) - Body ground Power switch on (IG) 1 V or less
z24-18 (TB5) - Body ground Power switch on (IG) 1 V or less
z24-6 (GB5) - Body ground Power switch on (IG) 1 V or less
z24-21 (TC0) - Body ground Power switch on (IG) 1 V or less
z24-9 (GC0) - Body ground Power switch on (IG) 1 V or less
z24-22 (TC1) - Body ground Power switch on (IG) 1 V or less
z24-10 (GC1) - Body ground Power switch on (IG) 1 V or less


Text in Illustration
*a Rear view of wire harness connector
(to Battery Smart Unit)


NOTICE:

If the power switch is turned on (IG) with the connectors disconnected, other DTCs will be stored. Be sure to clear the DTCs after the inspection.


g.

Turn the power switch off.


h.

Disconnect the cable from the negative (-) auxiliary battery terminal.


i.

Reconnect the z24 battery smart unit connector.


j.

Install the No. 1 hybrid battery shield sub-assembly.



OK

NG

5.CHECK HARNESS AND CONNECTOR (BATTERY TEMPERATURE SENSOR AND INLET AIR TEMPERATURE SENSOR)
5.CHECK HARNESS AND CONNECTOR (BATTERY TEMPERATURE SENSOR AND INLET AIR TEMPERATURE SENSOR)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the No. 1 hybrid battery shield sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>REMOVAL).


c.

Check the wire harness and connectors of the battery temperature sensor and inlet air temperature sensor for abnormalities by sight and touch.

Specified Condition:

There are no open or short circuits in the wire harness and connectors. There are no short circuits to other wire harnesses.



d.

Install the No. 1 hybrid battery shield sub-assembly.



OK

NG

REPAIR HARNESS OR CONNECTOR (BATTERY TEMPERATURE SENSOR AND INLET AIR TEMPERATURE SENSOR)

6.CHECK HARNESS AND CONNECTOR (VOLTAGE)
a.

Remove the front seat assembly RH.



b.

Turn over the front floor carpet.


c.

Disconnect the S30 battery cooling blower assembly connector.


d.

Turn the power switch on (IG).


e.
U190502E02
1.896,1.406 2.448,1.01 true 1.896,1.552 2.427,1.771 true 1.302,0.344 1.479,0.542 0.177,0.198 10 false *a 2.49,0.917 2.823,1.146 0.333,0.229 10 false VM0 2.469,1.698 2.917,1.927 0.448,0.229 10 false GND0 0.927,1.167 1.24,1.365 0.313,0.198 10 false S30

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
S30-2 (VM0) - S30-4 (GND0) Power switch on (IG) Below 5 V


Text in Illustration
*a Front view of wire harness connector
(to Battery Cooling Blower Assembly)

NOTICE:

If the power switch is turned on (IG) with the connectors disconnected, other DTCs will be stored. Be sure to clear the DTCs after the inspection.



f.

Turn the power switch off.


g.

Reconnect the S30 battery cooling blower assembly connector.


h.

Install the front floor carpet.


i.

Install the front seat assembly RH.



OK

REPLACE BATTERY COOLING BLOWER ASSEMBLY

NG

7.CHECK HARNESS AND CONNECTOR (BATTERY COOLING BLOWER - BATTERY SMART UNIT)
7.CHECK HARNESS AND CONNECTOR (BATTERY COOLING BLOWER - BATTERY SMART UNIT)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the front seat assembly RH.



c.

Turn over the front floor carpet.


d.

Disconnect the S30 battery cooling blower assembly connector.


e.

Remove the No. 1 hybrid battery shield sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>REMOVAL).


f.
U190660E02
2.51,0.5 2.854,0.656 0.344,0.156 10 false L144

Disconnect the L144 battery smart unit connector.


g.
U190623E02
1.885,0.865 2.542,0.615 true 0.448,4.021 0.958,3.771 true 1.083,0.031 1.25,0.271 0.167,0.24 10 false *a 1.26,1.708 1.427,1.948 0.167,0.24 10 false *b 0.906,0.833 1.208,1.01 0.302,0.177 10 false S30 2.604,0.51 2.938,0.677 0.333,0.167 10 false VM0 0.198,3.969 0.531,4.135 0.333,0.167 10 false VM 1.771,3.49 2.188,3.667 0.417,0.177 10 false L144

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
S30-2 (VM0) and L144-8 (VM) - Other terminal Power switch off 10 kΩ or higher


Text in Illustration
*a Front view of wire harness connector
(to Battery Cooling Blower Assembly)
*b Rear view of wire harness connector
(to Battery Smart Unit)


h.

Reconnect the L144 battery smart unit connector.


i.

Install the No. 1 hybrid battery shield sub-assembly.


j.

Reconnect the S30 battery cooling blower assembly connector.


k.

Install the front floor carpet.


l.

Install the front seat assembly RH.



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR