Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID BATTERY SYSTEM › from 2016.05
RM2070E _51 Engine / Hybrid System _061906 HYBRID / BATTERY CONTROL _0301574 HYBRID BATTERY SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID BATTERY SYSTEM  P301A-123  Open in Hybrid Battery Cell Voltage Detection Circuit  


DESCRIPTION

The hybrid vehicle control ECU alerts the driver and performs fail-safe control based on error signals sent from the battery smart unit.

DTC No. INF Code DTC Detection Condition Trouble Area
P301A 123 Open in battery block voltage detection circuit
(1 trip detection)

HV battery




WIRING DIAGRAM

A309625E09
2.479,5.844 3.302,6.042 0.823,0.198 10 false HV Battery 2.385,5 3.406,5.198 1.021,0.198 10 false Battery Block 0 2.385,2.729 3.406,2.927 1.021,0.198 10 false Battery Block 1 5.375,5.75 5.792,5.948 0.417,0.198 10 false z32 5.677,5.75 6.896,5.948 1.219,0.198 10 false Battery Smart Unit 5.76,5.313 6.135,5.51 0.375,0.198 10 false GA0 5.542,0.583 5.719,0.781 0.177,0.198 10 false 4 5.542,1.042 5.688,1.24 0.146,0.198 10 false 8 5.479,1.281 5.719,1.479 0.24,0.198 10 false 12 5.479,1.521 5.771,1.719 0.292,0.198 10 false 16 5.479,2 5.76,2.198 0.281,0.198 10 false 11 5.542,1.771 5.813,1.969 0.271,0.198 10 false 7 5.479,2.24 5.781,2.438 0.302,0.198 10 false 15 5.542,2.76 5.719,2.958 0.177,0.198 10 false 2 5.542,3.302 5.719,3.5 0.177,0.198 10 false 6 5.479,3.563 5.677,3.76 0.198,0.198 10 false 10 5.479,3.792 5.698,3.99 0.219,0.198 10 false 14 5.542,4.042 5.719,4.24 0.177,0.198 10 false 1 5.542,4.26 5.719,4.458 0.177,0.198 10 false 5 5.542,4.5 5.635,4.698 0.094,0.198 10 false 9 5.479,5.219 5.813,5.417 0.333,0.198 10 false 13 5.76,4.583 6.135,4.781 0.375,0.198 10 false VA1 5.76,4.333 6.135,4.531 0.375,0.198 10 false VA2 5.76,4.115 6.135,4.313 0.375,0.198 10 false VA3 5.76,3.875 6.135,4.073 0.375,0.198 10 false VA4 5.76,3.646 6.135,3.844 0.375,0.198 10 false VA5 5.76,3.375 6.135,3.573 0.375,0.198 10 false VA6 5.76,2.823 6.135,3.021 0.375,0.198 10 false VA7 5.76,2.302 6.135,2.5 0.375,0.198 10 false VA8 5.75,2.073 6.135,2.281 0.385,0.208 10 false VA9 5.76,1.844 6.135,2.042 0.375,0.198 10 false VA10 5.76,1.615 6.135,1.813 0.375,0.198 10 false VA11 5.76,1.365 6.135,1.563 0.375,0.198 10 false VA12 5.74,1.115 6.115,1.313 0.375,0.198 10 false VA13 5.76,0.688 6.135,0.885 0.375,0.198 10 false VA14

A309626E17
2.479,5.844 3.302,6.042 0.823,0.198 10 false HV Battery 2.385,5 3.406,5.198 1.021,0.198 10 false Battery Block 2 2.385,2.729 3.406,2.927 1.021,0.198 10 false Battery Block 3 5.375,5.75 5.792,5.948 0.417,0.198 10 false z33 5.677,5.75 6.896,5.948 1.219,0.198 10 false Battery Smart Unit 5.771,5.313 6.375,5.51 0.604,0.198 10 false GA1 5.531,0.583 5.802,0.781 0.271,0.198 10 false 5 5.458,1.042 5.75,1.24 0.292,0.198 10 false 10 5.458,1.281 5.792,1.479 0.333,0.198 10 false 15 5.531,1.521 5.896,1.719 0.365,0.198 10 false 4 5.458,2 5.802,2.198 0.344,0.198 10 false 14 5.531,1.771 5.875,1.969 0.344,0.198 10 false 9 5.531,2.24 5.865,2.438 0.333,0.198 10 false 3 5.531,2.76 5.823,2.958 0.292,0.198 10 false 8 5.458,3.302 5.885,3.5 0.427,0.198 10 false 13 5.531,3.552 5.917,3.76 0.385,0.208 10 false 2 5.542,3.792 5.927,3.99 0.385,0.198 10 false 7 5.458,4.042 5.938,4.24 0.479,0.198 10 false 12 5.531,4.26 5.906,4.458 0.375,0.198 10 false 1 5.521,4.5 5.833,4.698 0.313,0.198 10 false 6 5.458,5.219 5.792,5.417 0.333,0.198 10 false 11 5.771,4.583 6.573,4.781 0.802,0.198 10 false VA15 5.771,4.344 6.354,4.542 0.583,0.198 10 false VA16 5.771,4.125 6.323,4.323 0.552,0.198 10 false VA17 5.771,3.896 6.365,4.094 0.594,0.198 10 false VA18 5.771,3.667 6.385,3.865 0.615,0.198 10 false VA19 5.771,3.406 6.333,3.604 0.563,0.198 10 false VA20 5.771,2.854 6.323,3.052 0.552,0.198 10 false VA21 5.771,2.333 6.438,2.531 0.667,0.198 10 false VA22 5.771,2.104 6.354,2.313 0.583,0.208 10 false VA23 5.771,1.875 6.292,2.073 0.521,0.198 10 false VA24 5.771,1.625 6.302,1.823 0.531,0.198 10 false VA25 5.771,1.396 6.406,1.594 0.635,0.198 10 false VA26 5.771,1.146 6.333,1.344 0.563,0.198 10 false VA27 5.771,0.677 6.385,0.875 0.615,0.198 10 false VA28

A309626E18
2.479,5.844 3.302,6.042 0.823,0.198 10 false HV Battery 2.385,4.99 3.406,5.188 1.021,0.198 10 false Battery Block 4 2.385,2.729 3.406,2.927 1.021,0.198 10 false Battery Block 5 5.375,5.75 5.792,5.948 0.417,0.198 10 false z30 5.677,5.75 6.896,5.948 1.219,0.198 10 false Battery Smart Unit 5.771,5.313 6.375,5.51 0.604,0.198 10 false GA2 5.531,0.583 5.802,0.781 0.271,0.198 10 false 5 5.458,1.042 5.75,1.24 0.292,0.198 10 false 10 5.458,1.281 5.792,1.479 0.333,0.198 10 false 15 5.531,1.521 5.896,1.719 0.365,0.198 10 false 4 5.458,2 5.802,2.198 0.344,0.198 10 false 14 5.531,1.771 5.875,1.969 0.344,0.198 10 false 9 5.531,2.24 5.865,2.438 0.333,0.198 10 false 3 5.531,2.76 5.823,2.958 0.292,0.198 10 false 8 5.458,3.302 5.885,3.5 0.427,0.198 10 false 13 5.531,3.552 5.917,3.76 0.385,0.208 10 false 2 5.542,3.792 5.927,3.99 0.385,0.198 10 false 7 5.458,4.042 5.938,4.24 0.479,0.198 10 false 12 5.531,4.26 5.906,4.458 0.375,0.198 10 false 1 5.521,4.5 5.833,4.698 0.313,0.198 10 false 6 5.458,5.219 5.792,5.417 0.333,0.198 10 false 11 5.771,4.583 6.573,4.781 0.802,0.198 10 false VA29 5.771,4.344 6.354,4.542 0.583,0.198 10 false VA30 5.771,4.125 6.323,4.323 0.552,0.198 10 false VA31 5.771,3.896 6.365,4.094 0.594,0.198 10 false VA32 5.771,3.667 6.385,3.865 0.615,0.198 10 false VA33 5.771,3.406 6.333,3.604 0.563,0.198 10 false VA34 5.771,2.854 6.323,3.052 0.552,0.198 10 false VA35 5.771,2.333 6.438,2.531 0.667,0.198 10 false VA36 5.771,2.104 6.354,2.313 0.583,0.208 10 false VA37 5.771,1.875 6.292,2.073 0.521,0.198 10 false VA38 5.771,1.625 6.302,1.823 0.531,0.198 10 false VA39 5.771,1.396 6.406,1.594 0.635,0.198 10 false VA40 5.771,1.146 6.333,1.344 0.563,0.198 10 false VA41 5.771,0.677 6.385,0.875 0.615,0.198 10 false VA42

A309627E12
2.479,5.844 3.302,6.042 0.823,0.198 10 false HV Battery 2.385,5 3.406,5.198 1.021,0.198 10 false Battery Block 6 2.385,2.729 3.406,2.927 1.021,0.198 10 false Battery Block 7 5.375,5.75 5.792,5.948 0.417,0.198 10 false z31 5.677,5.75 6.896,5.948 1.219,0.198 10 false Battery Smart Unit 5.76,5.313 6.135,5.51 0.375,0.198 10 false GA3 5.542,0.583 5.719,0.781 0.177,0.198 10 false 4 5.542,1.042 5.688,1.24 0.146,0.198 10 false 8 5.479,1.281 5.719,1.479 0.24,0.198 10 false 12 5.479,1.521 5.771,1.719 0.292,0.198 10 false 16 5.479,2 5.76,2.198 0.281,0.198 10 false 11 5.542,1.771 5.813,1.969 0.271,0.198 10 false 7 5.479,2.24 5.781,2.438 0.302,0.198 10 false 15 5.542,2.76 5.719,2.958 0.177,0.198 10 false 2 5.542,3.302 5.719,3.5 0.177,0.198 10 false 6 5.479,3.563 5.677,3.76 0.198,0.198 10 false 10 5.479,3.792 5.698,3.99 0.219,0.198 10 false 14 5.542,4.042 5.719,4.24 0.177,0.198 10 false 1 5.542,4.26 5.719,4.458 0.177,0.198 10 false 5 5.542,4.5 5.635,4.698 0.094,0.198 10 false 9 5.479,5.219 5.813,5.417 0.333,0.198 10 false 13 5.76,4.583 6.135,4.781 0.375,0.198 10 false VA43 5.76,4.333 6.135,4.531 0.375,0.198 10 false VA44 5.76,4.115 6.135,4.313 0.375,0.198 10 false VA45 5.76,3.875 6.135,4.073 0.375,0.198 10 false VA46 5.76,3.646 6.135,3.844 0.375,0.198 10 false VA47 5.76,3.375 6.135,3.573 0.375,0.198 10 false VA48 5.76,2.823 6.135,3.021 0.375,0.198 10 false VA49 5.76,2.302 6.135,2.5 0.375,0.198 10 false VA50 5.75,2.073 6.135,2.281 0.385,0.208 10 false VA51 5.76,1.844 6.135,2.042 0.375,0.198 10 false VA52 5.76,1.615 6.135,1.813 0.375,0.198 10 false VA53 5.76,1.365 6.135,1.563 0.375,0.198 10 false VA54 5.74,1.115 6.115,1.313 0.375,0.198 10 false VA55 5.76,0.688 6.135,0.885 0.375,0.198 10 false VA56

CAUTION / NOTICE / HINT

CAUTION:
·

Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·

After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>PRECAUTION).

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.


·

When disposing of HV battery, make sure to return them through an authorized collection agent who is capable of handling them safely. If they are returned via the manufacturer specified route, they will be returned properly and in a safe manner by an authorized collection agent.

·

Before returning the HV battery, make sure to perform a recovery inspection (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>RECOVERY INSPECTION)

·

Make a note of the output DTCs as some of them may be necessary for recovery inspection of the HV battery.



NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).


PROCEDURE

1.CHECK DTC OUTPUT (HYBRID CONTROL)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.


d.

Read output DTCs.

Result:
Result Proceed to
P301B-123 is not output A
P301B-123 is output B



e.

Turn the power switch off.



A

2.CHECK DTC OUTPUT (HYBRID CONTROL)

B

2.CHECK DTC OUTPUT (HYBRID CONTROL)

A

3.CHECK DTC OUTPUT (HYBRID CONTROL)

B

3.CHECK DTC OUTPUT (HYBRID CONTROL)

A

4.CHECK CONNECTOR CONNECTION CONDITION (BATTERY SMART UNIT CONNECTOR)

B

4.CHECK CONNECTOR CONNECTION CONDITION (BATTERY SMART UNIT CONNECTOR)

OK

5.CLEAR DTC (HYBRID CONTROL)

NG

CONNECT SECURELY

5.CLEAR DTC (HYBRID CONTROL)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.


d.

Clear the DTCs and freeze frame data.

NOTICE:

When DTCs are cleared, freeze frame data and INF codes are also cleared.



e.

Turn the power switch off.



NEXT

6.RECONFIRM DTC OUTPUT
6.RECONFIRM DTC OUTPUT
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.


d.

Read output DTCs.

Result:
Result Proceed to
P301A-123 is not output A
P301A-123 is output B



e.

Turn the power switch off.



A

RETURNS TO NORMAL OPERATION

B

7.CHECK HV BATTERY (BATTERY CELL VOLTAGE)
7.CHECK HV BATTERY (BATTERY CELL VOLTAGE)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the No. 1 hybrid battery shield sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>REMOVAL).


c.

Disconnect the z32 battery smart unit connector.


d.
U190742E02
2.729,3.135 2.354,3.531 true 2.74,3 2.969,3.146 true 2.74,2.938 2.99,2.865 true 2.656,3.135 2.094,3.385 true 2.646,3 2.042,2.854 true 2.646,2.938 2.25,2.594 true 2.656,3.063 2.083,3.125 true 2.75,3.073 2.969,3.375 true 2.531,2.167 2.948,2.354 0.417,0.188 10 false z32 0.177,0.135 0.344,0.302 0.167,0.167 10 false *a 3.021,2.771 3.385,2.938 0.365,0.167 10 false VA3 2.99,3.063 3.354,3.229 0.365,0.167 10 false VA2 1.74,2.75 2.052,2.917 0.313,0.167 10 false VA6 1.771,3.052 2.063,3.219 0.292,0.167 10 false VA5 1.781,3.333 2.094,3.5 0.313,0.167 10 false VA4 2.198,3.542 2.563,3.708 0.365,0.167 10 false GA0 1.927,2.469 2.229,2.667 0.302,0.198 10 false VA7 2.938,3.375 3.302,3.542 0.365,0.167 10 false VA1

Measure the voltage according to the value(s) in the table below.

Standard Voltage (Battery Block 0):
Tester Connection Switch Condition Specified Condition
z32-13 (GA0) - z32-9 (VA1) Power switch off Below 1.9 V
z32-9 (VA1) - z32-5 (VA2) Power switch off Below 1.9 V
z32-5 (VA2) - z32-1 (VA3) Power switch off Below 1.9 V
z32-1 (VA3) - z32-14 (VA4) Power switch off Below 1.9 V
z32-14 (VA4) - z32-10 (VA5) Power switch off Below 1.9 V
z32-10 (VA5) - z32-6 (VA6) Power switch off Below 1.9 V
z32-6 (VA6) - z32-2 (VA7) Power switch off Below 1.9 V


Text in Illustration
*a Rear view of wire harness connector
(to Battery Smart Unit)

NOTICE:

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.



e.
U190743E02
2.51,3.135 2.229,3.531 true 2.604,3.073 2.938,3.281 true 2.5,3.063 2.052,3.333 true 2.667,2.938 2.979,2.771 true 2.594,3.135 2.865,3.51 true 2.51,2.938 2.021,2.875 true 2.51,3 1.938,3.125 true 2.594,3 2.927,3.021 true 2.542,2.167 2.927,2.354 0.385,0.188 10 false z32 0.177,0.135 0.344,0.302 0.167,0.167 10 false *a 2.958,3.229 3.323,3.396 0.365,0.167 10 false VA9 1.542,3.042 1.938,3.208 0.396,0.167 10 false VA13 1.646,3.292 2.021,3.458 0.375,0.167 10 false VA12 2.781,3.542 3.094,3.708 0.313,0.167 10 false VA8 2.021,3.542 2.385,3.708 0.365,0.167 10 false VA11 3.01,2.677 3.313,2.875 0.302,0.198 10 false VA7 1.635,2.781 2.031,2.948 0.396,0.167 10 false VA14 2.969,2.948 3.344,3.115 0.375,0.167 10 false VA10

Measure the voltage according to the value(s) in the table below.

Standard Voltage (Battery Block 1):
Tester Connection Switch Condition Specified Condition
z32-2 (VA7) - z32-15 (VA8) Power switch off Below 1.9 V
z32-15 (VA8) - z32-11 (VA9) Power switch off Below 1.9 V
z32-11 (VA9) - z32-7 (VA10) Power switch off Below 1.9 V
z32-7 (VA10) - z32-16 (VA11) Power switch off Below 1.9 V
z32-16 (VA11) - z32-12 (VA12) Power switch off Below 1.9 V
z32-12 (VA12) - z32-8 (VA13) Power switch off Below 1.9 V
z32-8 (VA13) - z32-4 (VA14) Power switch off Below 1.9 V


Text in Illustration
*a Rear view of wire harness connector
(to Battery Smart Unit)

NOTICE:

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.



f.

Reconnect the z32 battery smart unit connector.


g.

Disconnect the z33 battery smart unit connector.


h.
U190738E02
2.156,2.833 2.156,2.313 true 2.24,2.844 2.688,2.323 true 2.24,2.906 2.688,2.906 true 2.083,2.844 1.406,2.51 false 2.073,2.844 1.396,2.51 true 2.083,2.906 1.406,3.24 false 2.083,2.906 1.406,3.24 true 2.156,2.906 2.375,3.417 true 2.146,2.979 1.698,3.5 true 2.24,2.969 2.667,3.188 true 2,3.802 2.375,3.99 0.375,0.188 10 false z33 0.177,0.104 0.344,0.271 0.167,0.167 10 false *a 2,2.125 2.365,2.292 0.365,0.167 10 false VA19 2.615,2.146 2.979,2.313 0.365,0.167 10 false VA16 2.719,2.844 3.083,3.01 0.365,0.167 10 false VA15 1.01,2.417 1.375,2.583 0.365,0.167 10 false VA21 1.031,3.177 1.396,3.344 0.365,0.167 10 false VA20 2.26,3.438 2.625,3.604 0.365,0.167 10 false VA18 1.448,3.531 1.813,3.698 0.365,0.167 10 false VA17 2.708,3.135 3.073,3.302 0.365,0.167 10 false GA1

Measure the voltage according to the value(s) in the table below.

Standard Voltage (Battery Block 2):
Tester Connection Switch Condition Specified Condition
z33-11 (GA1) - z33-6 (VA15) Power switch off Below 1.9 V
z33-6 (VA15) - z33-1 (VA16) Power switch off Below 1.9 V
z33-1 (VA16) - z33-12 (VA17) Power switch off Below 1.9 V
z33-12 (VA17) - z33-7 (VA18) Power switch off Below 1.9 V
z33-7 (VA18) - z33-2 (VA19) Power switch off Below 1.9 V
z33-2 (VA19) - z33-13 (VA20) Power switch off Below 1.9 V
z33-13 (VA20) - z33-8 (VA21) Power switch off Below 1.9 V


Text in Illustration
*a Rear view of wire harness connector
(to Battery Smart Unit)

NOTICE:

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.



i.
U190739E02
2,2.833 2,2.313 true 2.094,2.844 2.542,2.323 true 2,2.927 2.583,3.271 true 1.917,2.844 1.469,2.323 true 1.927,2.906 1.25,2.573 true 1.917,2.969 1.24,3.302 true 2.083,2.906 2.729,2.688 true 2,2.969 1.552,3.49 true 2.01,3.802 2.479,3.99 0.469,0.188 10 false z33 0.177,0.104 0.344,0.271 0.167,0.167 10 false *a 1.833,2.094 2.198,2.26 0.365,0.167 10 false VA25 2.458,2.125 2.823,2.292 0.365,0.167 10 false VA22 2.625,3.198 2.99,3.365 0.365,0.167 10 false VA24 1.188,2.125 1.552,2.292 0.365,0.167 10 false VA28 0.875,2.458 1.24,2.625 0.365,0.167 10 false VA27 0.875,3.281 1.24,3.448 0.365,0.167 10 false VA26 2.76,2.552 3.198,2.771 0.438,0.219 10 false VA21 1.271,3.51 1.635,3.677 0.365,0.167 10 false VA23

Measure the voltage according to the value(s) in the table below.

Standard Voltage (Battery Block 3):
Tester Connection Switch Condition Specified Condition
z33-8 (VA21) - z33-3 (VA22) Power switch off Below 1.9 V
z33-3 (VA22) - z33-14 (VA23) Power switch off Below 1.9 V
z33-14 (VA23) - z33-9 (VA24) Power switch off Below 1.9 V
z33-9 (VA24) - z33-4 (VA25) Power switch off Below 1.9 V
z33-4 (VA25) - z33-15 (VA26) Power switch off Below 1.9 V
z33-15 (VA26) - z33-10 (VA27) Power switch off Below 1.9 V
z33-10 (VA27) - z33-5 (VA28) Power switch off Below 1.9 V


Text in Illustration
*a Rear view of wire harness connector
(to Battery Smart Unit)

NOTICE:

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.



j.

Reconnect the z33 battery smart unit connector.


k.

Disconnect the z30 battery smart unit connector.


l.
U190734E02
1.698,2.844 1.958,2.542 true 1.542,2.906 0.865,2.781 true 1.531,2.969 0.854,3.24 true 1.615,2.896 2.094,2.802 true 1.615,2.979 1.167,3.5 true 1.698,2.906 2.115,3.177 true 1.625,2.833 1.188,2.458 true 1.698,2.979 1.865,3.458 true 1.458,2.115 1.76,2.302 0.302,0.188 10 false z30 0.177,0.135 0.344,0.302 0.167,0.167 10 false *a 0.833,2.344 1.198,2.51 0.365,0.167 10 false VA33 1.979,2.406 2.344,2.573 0.365,0.167 10 false VA30 2.135,3.135 2.5,3.302 0.365,0.167 10 false VA29 0.479,2.656 0.844,2.823 0.365,0.167 10 false VA35 0.49,3.167 0.854,3.333 0.365,0.167 10 false VA34 2.125,2.698 2.49,2.865 0.365,0.167 10 false VA32 0.906,3.5 1.271,3.667 0.365,0.167 10 false VA31 1.792,3.479 2.156,3.646 0.365,0.167 10 false GA2

Measure the voltage according to the value(s) in the table below.

Standard Voltage (Battery block 4):
Tester Connection Switch Condition Specified Condition
z30-11 (GA2) - z30-6 (VA29) Power switch off Below 1.9 V
z30-6 (VA29) - z30-1 (VA30) Power switch off Below 1.9 V
z30-1 (VA30) - z30-12 (VA31) Power switch off Below 1.9 V
z30-12 (VA31) - z30-7 (VA32) Power switch off Below 1.9 V
z30-7 (VA32) - z30-2 (VA33) Power switch off Below 1.9 V
z30-2 (VA33) - z30-13 (VA34) Power switch off Below 1.9 V
z30-13 (VA34) - z30-8 (VA35) Power switch off Below 1.9 V


Text in Illustration
*a Rear view of wire harness connector
(to Battery Smart Unit)

NOTICE:

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.



m.
U190735E02
1.375,2.896 0.802,2.781 true 1.469,2.906 1.271,3.281 true 1.469,2.979 1.906,3.365 true 1.552,2.906 2.021,3.094 true 1.552,2.844 2.156,2.677 true 1.375,2.969 0.875,3.083 true 1.375,2.833 1,2.542 true 1.469,2.844 1.958,2.458 true 1.458,2.104 1.802,2.292 0.344,0.188 10 false z30 0.177,0.135 0.344,0.302 0.167,0.167 10 false *a 2.208,2.583 2.573,2.75 0.365,0.167 10 false VA36 2.073,3.021 2.5,3.208 0.427,0.188 10 false VA35 0.615,2.417 0.979,2.583 0.365,0.167 10 false VA42 0.417,2.688 0.781,2.854 0.365,0.167 10 false VA41 0.5,3.01 0.865,3.177 0.365,0.167 10 false VA40 1.052,3.292 1.417,3.458 0.365,0.167 10 false VA38 1.948,3.323 2.313,3.49 0.365,0.167 10 false VA37 2,2.354 2.365,2.552 0.365,0.198 10 false VA39

Measure the voltage according to the value(s) in the table below.

Standard Voltage (Battery block 5):
Tester Connection Switch Condition Specified Condition
z30-8 (VA35) - z30-3 (VA36) Power switch off Below 1.9 V
z30-3 (VA36) - z30-14 (VA37) Power switch off Below 1.9 V
z30-14 (VA37) - z30-9 (VA38) Power switch off Below 1.9 V
z30-9 (VA38) - z30-4 (VA39) Power switch off Below 1.9 V
z30-4 (VA39) - z30-15 (VA40) Power switch off Below 1.9 V
z30-15 (VA40) - z30-10 (VA41) Power switch off Below 1.9 V
z30-10 (VA41) - z30-5 (VA42) Power switch off Below 1.9 V


Text in Illustration
*a Rear view of wire harness connector
(to Battery Smart Unit)

NOTICE:

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.



n.

Reconnect the z30 battery smart unit connector.


o.

Disconnect the z31 battery smart unit connector.


p.
U190730E02
1.031,3.135 0.688,3.51 true 1.031,3.063 0.49,3.302 true 1.135,3.01 1.573,3.146 true 1.125,2.938 1.646,2.823 true 1.042,3.01 0.583,3.01 true 1.031,2.938 0.604,2.719 true 1.125,3.073 1.542,3.396 true 1.125,3.135 1.26,3.563 true 0.906,2.208 1.25,2.396 0.344,0.188 10 false z31 0.177,0.135 0.344,0.302 0.167,0.167 10 false *a 1.688,2.719 2.052,2.885 0.365,0.167 10 false VA45 1.635,3.073 2,3.24 0.365,0.167 10 false VA44 0.208,2.927 0.573,3.094 0.365,0.167 10 false VA48 1.583,3.344 1.948,3.51 0.365,0.167 10 false VA43 0.479,3.531 0.844,3.698 0.365,0.167 10 false VA46 0.125,3.24 0.49,3.406 0.365,0.167 10 false VA47 0.24,2.615 0.604,2.813 0.365,0.198 10 false VA49 1.135,3.573 1.5,3.74 0.365,0.167 10 false GA3

Measure the voltage according to the value(s) in the table below.

Standard Voltage (Battery Block 6):
Tester Connection Switch Condition Specified Condition
z31-13 (GA3) - z31-9 (VA43) Power switch off Below 1.9 V
z31-9 (VA43) - z31-5 (VA44) Power switch off Below 1.9 V
z31-5 (VA44) - z31-1 (VA45) Power switch off Below 1.9 V
z31-1 (VA45) - z31-14 (VA46) Power switch off Below 1.9 V
z31-14 (VA46) - z31-10 (VA47) Power switch off Below 1.9 V
z31-10 (VA47) - z31-6 (VA48) Power switch off Below 1.9 V
z31-6 (VA48) - z31-2 (VA49) Power switch off Below 1.9 V


Text in Illustration
*a Rear view of wire harness connector
(to Battery Smart Unit)

NOTICE:

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.



q.
U190731E02
0.885,3 0.625,2.854 true 0.885,3.135 0.625,3.365 true 0.969,3.135 0.854,3.656 true 0.979,3.073 1.417,3.385 true 0.875,3.073 0.563,3.135 true 0.896,2.938 1.438,2.594 true 0.969,3.01 1.521,3.104 true 1.052,2.948 1.458,2.875 true 0.917,2.198 1.24,2.385 0.323,0.188 10 false z31 0.177,0.135 0.344,0.302 0.167,0.167 10 false *a 1.406,3.406 1.771,3.583 0.365,0.177 10 false VA51 1.469,2.49 1.833,2.656 0.365,0.167 10 false VA56 0.25,2.771 0.615,2.938 0.365,0.167 10 false VA55 0.188,3.063 0.552,3.229 0.365,0.167 10 false VA54 0.271,3.354 0.635,3.521 0.365,0.167 10 false VA53 0.667,3.667 1.031,3.833 0.365,0.167 10 false VA50 1.552,3.042 1.917,3.24 0.365,0.198 10 false VA52 1.49,2.771 1.854,2.938 0.365,0.167 10 false VA49

Measure the voltage according to the value(s) in the table below.

Standard Voltage (Battery Block 7):
Tester Connection Switch Condition Specified Condition
z31-2 (VA49) - z31-15 (VA50) Power switch off Below 1.9 V
z31-15 (VA50) - z31-11 (VA51) Power switch off Below 1.9 V
z31-11 (VA51) - z31-7 (VA52) Power switch off Below 1.9 V
z31-7 (VA52) - z31-16 (VA53) Power switch off Below 1.9 V
z31-16 (VA53) - z31-12 (VA54) Power switch off Below 1.9 V
z31-12 (VA54) - z31-8 (VA55) Power switch off Below 1.9 V
z31-8 (VA55) - z31-4 (VA56) Power switch off Below 1.9 V


Text in Illustration
*a Rear view of wire harness connector
(to Battery Smart Unit)

NOTICE:

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.


Result:
Result Proceed to
Voltage between each pair of terminals is below 1.9 V. B
Other than above. A



r.

Reconnect the z31 battery smart unit connector.


s.

Install the No. 1 hybrid battery shield sub-assembly.



A

B