82112
1.INSTALL NO. 2 ENGINE ROOM WIRE
Perform this procedure only when replacement of the No. 2 engine room wire is necessary.
Engage the clamp to Install a the No. 2 engine room wire to the inverter with converter assembly.
Install the nut to the No. 2 engine room wire.
Engage the 2 claws and close the terminal cover.
2.INSTALL HIGH VOLTAGE FUSE
Wear insulated gloves.
Perform this procedure only when replacement of the high voltage fuse is necessary.
Remove the 9 bolts and inverter cover.
Make sure to pull the inverter cover straight up, as a connector is connected to the bottom of the cover.
Install the high voltage fuse with the 2 bolts.
| *a | CORRECT |
| *b | INCORRECT |
Be sure to use a torque wrench to tighten the bolts.
The fuse should be installed with its orientation as shown in the illustration.
Temporarily install the inverter cover with the 9 bolts to prevent any foreign matter or water from entering the inverter with converter assembly.
G1143
3.INSTALL MOTOR CABLE BRACKET
Temporarily install the motor cable bracket with the 2 bolts.
Tighten the 2 bolts in the order shown in the illustration.
G9200
4.INSTALL INVERTER WITH CONVERTER ASSEMBLY
Wear insulated gloves.
Temporarily install the inverter with converter assembly with the 3 bolts.
Since the inverter with converter assembly is very heavy, 2 people are needed to install the inverter with converter assembly. When installing the inverter with converter assembly, do not damage the parts around it.
To prevent damage, do not hold the inverter with converter assembly by the connectors.
To prevent damage due to static electricity, do not touch the terminals of the disconnected connectors.
Tighten bolt A.
Tighten the 2 bolts.
5.CONNECT WATER HOSE
Connect the water hose to the inverter with converter assembly and lock the hose with the retainer.
Insert the retainer until a click sound is heard.
Pull on the hose to confirm that the hose is securely connected.
If there is foreign matter on the union or the O-ring, clean it with water and finger scouring.
To prevent foreign matter from entering the cooling system, do not remove the pieces of cloth or plastic bags from the pipes and disconnected hoses until installation.
Connect the water hose to the inverter with converter assembly and lock the hose with the retainer.
Insert the retainer until a click sound is heard.
Pull on the hose to confirm that the hose is securely connected.
If there is foreign matter on the union or the O-ring, clean it with water and finger scouring.
To prevent foreign matter from entering the cooling system, do not remove the pieces of cloth or plastic bags from the pipes and disconnected hoses until installation.
82112
6.CONNECT NO. 2 ENGINE ROOM WIRE
Disconnect the No. 2 engine room wire from the protector.
Connect the No. 2 engine room wire with the bolt and 2 claws.
Pass the No. 2 engine room wire under the 2 cooling hoses that pass beside the inverter with converter assembly.
Install the No. 1 relay block cover and 2 clamps.
Install the relay block cover.
G9221
7.REMOVE INVERTER COVER
Wear insulated gloves.
Remove the 9 bolts and inverter cover.
Make sure to pull the inverter cover straight up, as a connector is connected to the bottom of the cover.
82122
8.CONNECT NO. 2 ENGINE WIRE
Wear insulated gloves.
Do not allow any foreign matter or water to enter the inverter with converter assembly.
Temporarily install the No. 2 engine wire (high voltage cables of the air conditioning) and 4 bolts to the inverter with converter assembly by hand.
Fully tighten the 4 bolts.
Be sure to use a torque wrench to tighten the bolts.
Connect the harness clamp.
G1148
9.CONNECT MOTOR CABLE
Wear insulated gloves.
Do not allow any foreign matter or water to enter the inverter with converter assembly.
Temporarily install the high voltage cable of the motor cable (MG2) and 5 bolts to the inverter with converter assembly by hand.
Fully tighten the 5 bolts.
Be sure to use a torque wrench to tighten the bolts.
Connect the harness clamp.
G2148
10.CONNECT GENERATOR CABLE
Wear insulated gloves.
Do not allow any foreign matter or water to enter the inverter with converter assembly.
Temporarily install the high voltage cable of the generator cable (MG1) and 5 bolts to the inverter with converter assembly by hand.
Fully tighten the 5 bolts.
Be sure to use a torque wrench to tighten the bolts.
Install the generator cable and cover.
| *a | Alignment Mark |
Close the cover so that the alignment marks are not visible.
82164
11.CONNECT FRAME WIRE
Wear insulated gloves.
Make sure that the interlock is fully engaged.
Do not allow any foreign matter or water to enter the inverter with converter assembly.
Temporarily install the frame wire (high voltage cables of the hybrid battery) and 4 bolts to the inverter with converter assembly by hand.
| *1 | Interlock |
| *2 | High voltage cables of hybrid battery |
| *a | Front view of frame wire connector |
Fully tighten the 4 bolts.
Be sure to use a torque wrench to tighten the bolts.
Make sure that the interlock are fully engaged.
Connect the harness clamp.
12. CHECK HIGH VOLTAGE CABLE CONNECTION
Wear insulated gloves.
Do not allow any foreign matter or water to enter the inverter with converter assembly.
Check that each connector and terminal is firmly installed.
Make sure that the bolts are fully tightened.
G9221
13.INSTALL INVERTER COVER
Wear insulated gloves.
Install the inverter cover with the 9 bolts to the inverter with converter assembly.
| *1 | Interlock |
Make sure that the interlock is fully engaged.
Do not allow any foreign matter or water to enter the inverter with converter assembly.
82111
14.CONNECT ENGINE ROOM MAIN WIRE
Make sure that the connectors are fully engaged.
Do not allow any foreign matter or water to enter the inverter with converter assembly.
Install the bolt, clamp and clip, and connect the engine room main wire.
Install the bolt.
Connect the engine wire to the engine room main wire.
Connect the connector to the inverter with converter assembly and lock the connector with the lock lever.
G9214
15.INSTALL NO. 1 INVERTER BRACKET
Temporarily install the No. 1 inverter bracket with the 3 bolts.
Tighten the 3 bolts in the order shown in the illustration.
G3834
16.INSTALL SERVICE PLUG GRIP
17.ADD COOLANT (for Inverter)
18.INSPECT FOR COOLANT LEAK (for Inverter)
51441
19.INSTALL NO. 1 ENGINE UNDER COVER
53289A
20.INSTALL RADIATOR SUPPORT OPENING COVER