Home › Engine / Hybrid System › 2ZR-FXE (COOLING) › EXHAUST PIPE GAS CONTROL ACTUATOR › 2012.03–2020.08
RM2070E _51 Engine / Hybrid System _061911 2ZR-FXE COOLING _0301627 EXHAUST PIPE GAS CONTROL ACTUATOR A

2ZR-FXE COOLING  EXHAUST PIPE GAS CONTROL ACTUATOR  REMOVAL  


PROCEDURE

Hide 17410 1.REMOVE FRONT EXHAUST PIPE ASSEMBLY

Hide 17046 3.REMOVE EXHAUST PIPE GAS CONTROL ACTUATOR SUB-ASSEMBLY

a.
A294176E01
2.058,1.927 2.231,2.086 0.173,0.159 10 *1 2.027,2.022 1.886,2.022 1.886,2.022 1.704,1.778 false

Clean the area shaded in the illustration to prevent foreign matter from entering the cooling system.

Text in Illustration
*1 Flange of Exhaust Pipe Gas Control Actuator Sub-assembly
V100145

Area to be Cleaned


b.
A290217

Remove the 5 bolts, exhaust pipe gas control actuator sub-assembly, exhaust by-pass pipe and No. 2 exhaust pipe heat insulator.

NOTICE:
·

When removing the exhaust pipe gas control actuator sub-assembly, use caution because coolant may spill out from the exhaust heat recirculation system.

·

Do not apply any excessive force to the exhaust by-pass pipe when removing the exhaust pipe gas control actuator sub-assembly.




c.

Remove the exhaust by-pass pipe from the exhaust pipe gas control actuator sub-assembly.