DTC P0116 Engine Coolant Temperature Circuit Range / Performance Problem |
| DTC No. | DTC Detection Condition | Trouble Area |
| P0116 | When either of the following conditions is met (2 trip detection logic).
|
|
| Related DTCs | P0116: Engine coolant temperature sensor rationality (cold start monitor) P0116: Engine coolant temperature sensor rationality (soak monitor) |
| Required Sensors/Components (Main) | Engine coolant temperature sensor |
| Required Sensors/Components (Related) | - |
| Frequency of Operation | Once per driving cycle |
| Duration | 10 seconds: Soak monitor -: Cold start monitor |
| MIL Operation | 2 driving cycles |
| Sequence of Operation | None |
| Monitor runs whenever the following DTCs are not stored | None |
| All of the following conditions are met | - |
| Auxiliary battery voltage | 10.5 V or higher |
| Time after engine start | 1 second or more |
| Engine coolant temperature at engine start | Less than 60°C (140°F) |
| Soak time | 0 second or more |
| Accumulated mass air flow | 2458.5 g or more |
| Fuel cut | Off |
| Intake air temperature sensor circuit fail (P0112, P0113) | Not detected |
| Engine coolant temperature sensor circuit fail (P0115, P0117, P0118, P0125) | Not detected |
| Engine water pump circuit fail (P261B, P261C, P261D) | Not detected |
| Thermostat fail (P0128) | Not detected |
| Difference between engine coolant temperature at engine start and intake air temperature | Less than 40°C (72°F) |
| All of the following conditions are met | - |
| Auxiliary battery voltage | 10.5 V or higher |
| Engine | Running |
| Soak time | 5 hours or more |
| Either of the following condition is met | 1 or 2 |
| 1. Engine coolant temperature | 60°C (140°F) or higher |
| 2. Accumulated mass air flow | 3917 g or more |
| Intake air temperature sensor circuit fail (P0112, P0113) | Not detected |
| Engine coolant temperature sensor circuit fail (P0115, P0117, P0118, P0125) | Not detected |
| Engine water pump circuit fail (P261B, P261C, P261D) | Not detected |
| Thermostat fail (P0128) | Not detected |
| Soak timer fail (P2610) | Not detected |
| Engine coolant temperature sensor value change | Less than 5°C (9°F) |
| Difference between current engine coolant temperature sensor value and previous engine coolant temperature sensor value when engine stopped | Less than 5°C (9°F) (varies with engine coolant temperature of last trip engine stop) |
| Engine coolant temperature | Engine coolant temperature sensor value changes in accordance with actual engine coolant temperature |

| Techstream Display | Description |
| NORMAL |
|
| ABNORMAL |
|
| INCOMPLETE |
|
| N/A |
|
| 1.CHECK ANY OTHER DTCS OUTPUT (IN ADDITION TO DTC P0116) |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON (IG).
Turn the Techstream on.
Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.
Read the DTCs.
| Result | Proceed to |
| DTC P0116 is output | A |
| DTC P0116 and other DTCs are output | B |
|
| ||||
| A | |
| 2.INSPECT WATER INLET WITH THERMOSTAT SUB-ASSEMBLY |
Inspect the water inlet with thermostat sub-assembly (thermostat opening temperature) (Click here).
|
| ||||
| OK | ||
| ||