DTC P0102 Mass or Volume Air Flow Circuit Low Input |
DTC P0103 Mass or Volume Air Flow Circuit High Input |

| DTC No. | DTC Detection Condition | Trouble Area |
| P0102 | The mass air flow meter sub-assembly voltage is less than 0.2 V for 3 seconds. (1 trip detection logic: Engine speed is less than 4000 rpm) (2 trip detection logic: Engine speed is 4000 rpm or higher) |
|
| P0103 | The mass air flow meter sub-assembly voltage is higher than 4.9 V for 3 seconds. (1 trip detection logic: Engine speed is less than 4000 rpm) (2 trip detection logic: Engine speed is 4000 rpm or higher) |
|
| Mass Air Flow Rate (gm/sec) | Malfunction |
| Approximately 0.0 |
|
| 271.0 or more |
|
| Related DTCs | P0102: Mass air flow meter range check (low voltage) P0103: Mass air flow meter range check (high voltage) |
| Required Sensors/Components (Main) | Mass air flow meter sub-assembly |
| Required Sensors/Components (Related) | Crank position sensor |
| Frequency of Operation | Continuous |
| Duration | 3 seconds |
| MIL Operation | Immediate: Engine speed less than 4000 rpm 2 driving cycles: Engine speed 4000 rpm or higher |
| Sequence of Operation | None |
| Monitor runs whenever the following DTCs are not stored | None |
| Mass air flow meter voltage | Less than 0.2 V |
| Mass air flow meter voltage | Higher than 4.9 V |
| Mass air flow meter voltage | 0.2 to 4.9 V |

| Techstream Display | Description |
| NORMAL |
|
| ABNORMAL |
|
| INCOMPLETE |
|
| N/A |
|

| 1.READ OUTPUT DTC (DTC P0102 OR P0103) |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON (IG).
Turn the Techstream on.
Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.
Read the DTCs.
| Result | Proceed to |
| DTC P0102 is output | A |
| DTC P0103 is output | B |
|
| ||||
| A | |
| 2.CHECK TERMINAL VOLTAGE (POWER SOURCE OF MASS AIR FLOW METER SUB-ASSEMBLY) |
![]() |
Disconnect the mass air flow meter sub-assembly connector.
Turn the ignition switch to ON (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| C21-3 (+B) - Body ground | Ignition switch ON (IG) | 11 to 14 V |
| *a | Front view of wire harness connector (to Mass Air Flow Meter Sub-assembly) |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER SUB-ASSEMBLY - ECM) |
Disconnect the mass air flow meter sub-assembly connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| C21-5 (VG) - C10-91 (VG) | Always | Below 1 Ω |
| C21-4 (E2G) - C10-92 (E2G) | Always | Below 1 Ω |
| C21-5 (VG) or C10-91 (VG) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 4.INSPECT MASS AIR FLOW METER SUB-ASSEMBLY |
Inspect the mass air flow meter sub-assembly, referring to the On-vehicle Inspection for Mass Air Flow Meter (Click here).
Inspect the mass air flow meter sub-assembly, referring to the Inspection for Mass Air Flow Meter (Click here).
Inspect the function of the mass air flow meter sub-assembly.
Connect the Techstream to the DLC3.
Turn the ignition switch to ON (IG).
Turn the Techstream on.
Put the engine in inspection mode (maintenance mode) (Click here).
Start the engine.
Enter the following menus: Powertrain / Engine and ECT / Data List / Primary / MAF.
Check that the MAF value changes when the engine is raced.
|
| ||||
| OK | ||
| ||
| 5.CHECK HARNESS AND CONNECTOR (SENSOR GROUND) |
Disconnect the mass air flow meter sub-assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| C21-4 (E2G) - Body ground | Always | Below 1 Ω |
|
| ||||
| OK | ||
| ||
| 6.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER SUB-ASSEMBLY - ECM) |
Disconnect the mass air flow meter sub-assembly connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| C21-4 (E2G) - C10-92 (E2G) | Always | Below 1 Ω |
|
| ||||
| OK | ||
| ||
| 7.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER SUB-ASSEMBLY - NO. 1 INTEGRATION RELAY) |
Disconnect the mass air flow meter sub-assembly connector.
Remove the No. 1 integration relay from the engine room relay block and junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| C21-3 (+B) - 2C-4 | Always | Below 1 Ω |
| C21-3 (+B) or 2C-4 - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||