POWER DOOR LOCK CONTROL SYSTEM > All Doors LOCK/UNLOCK Functions do not Operate Via Door Control Switch |

| 1.READ VALUE USING TECHSTREAM (DOOR CONTROL SWITCH ASSEMBLY) |
Connect the Techstream to the DLC3.
Turn the ignition switch ON (IG).
Turn the Techstream on.
Enter the following menus: Body Electrical / Main Body / Data List.
Read the Data List according to the display on the Techstream.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Door Lock SW-Lock | Door control switch assembly lock signal/ON or OFF | ON: Lock side of door control switch assembly pushed OFF: Lock side of door control switch assembly not pushed | - |
| Door Lock SW-Unlock | Door control switch assembly unlock signal/ON or OFF | ON: Unlock side of door control switch assembly pushed OFF: Unlock side of door control switch assembly not pushed | - |
|
| ||||
| OK | ||
| ||
| 2.INSPECT DOOR CONTROL SWITCH ASSEMBLY |
![]() |
Remove the door control switch assembly (Click here).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| 4 (L) - 3 (E) | Lock switch pushed | Below 1 Ω |
| 4 (L) - 3 (E) | Lock switch not pushed | 10 kΩ or higher |
| 2 (UL) - 3 (E) | Unlock switch pushed | Below 1 Ω |
| 2 (UL) - 3 (E) | Unlock switch not pushed | 10 kΩ or higher |
| *a | Component without harness connected (Door Control Switch Assembly) |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (DOOR CONTROL SWITCH ASSEMBLY - MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU)) |
Disconnect the G59 main body ECU (multiplex network body ECU) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| H5-2 (UL) - G59-10 (UL1) | Always | Below 1 Ω |
| H5-4 (L) - G59-9 (L1) | Always | Below 1 Ω |
| H5-3 (E) - Body ground | Always | Below 1 Ω |
| H5-2 (UL) - Body ground | Always | 10 kΩ or higher |
| H5-4 (L) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||