Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM

DTC    P0A7A-324    Generator Inverter Performance

for Preparation Click here


DESCRIPTION

For a description of the inverter .
If the generator inverter overheats, has a circuit malfunction or has an internal short, the inverter transmits this information to the MG ECU via the generator inverter fail signal line.

DTC No.
INF Code
DTC Detection Condition
Trouble Area
P0A7A
324
Generator inverter fail signal detection (circuit malfunction)
(1 trip detection logic)
  1. Inverter cooling system
  2. Cooling fan system
  3. Power management control ECU
  4. Inverter with converter assembly
  5. Hybrid vehicle transaxle assembly
  6. Motor cable
  7. Wire harness or connector
  8. PCU fuse

MONITOR DESCRIPTION

If the generator inverter detects a circuit malfunction, it will transmit a generator inverter fail signal to the MG ECU. Upon receiving this information, the power management control ECU will illuminate the MIL and set a DTC.

MONITOR STRATEGY


Related DTCs
P0A7A (INF 324): GFIV detection (Circuit malfunction)
Required sensors / components
Generator inverter
Frequency of operation
Continuous
Duration
TMC's intellectual property
MIL operation
1 driving cycle
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


The monitor will run whenever the following DTCs are not present
TMC's intellectual property
Other conditions belong to TMC's intellectual property
-

TYPICAL MALFUNCTION THRESHOLDS


TMC's intellectual property
-

COMPONENT OPERATING RANGE


Power management control ECU
DTC P0A7A (INF 324) is not detected

CONFIRMATION DRIVING PATTERN


A308311E09

  1. Connect the Techstream to the DLC3.
  2. Turn the ignition switch to ON (IG) and turn the Techstream on.
  3. Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
  4. Turn the ignition switch off and wait for 30 seconds or more.
  5. Turn the ignition switch to ON (IG) and turn the Techstream on.
  6. Turn the ignition switch to ON (READY).
  7. With the shift lever in P, wait for 5 seconds. [A]

    HINT:
    Check that there are no abnormalities (abnormal sounds, coolant leaks, DTC output, etc.)

  8. Drive the vehicle approximately 10 minutes mainly using the engine. [B]
  9. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes. [C]
  10. Read the current DTCs.

    HINT:
    1. If a current DTC is output, the system is malfunctioning.
    2. If a current DTC is not output, perform the following procedure.

  11. Check that permanent DTCs are cleared. If no permanent DTC is output, the system is normal.
  12. If the permanent DTCs are not cleared, perform a universal trip, and then check for permanent DTCs again.

WIRING DIAGRAM

Refer to the wiring diagram for DTC P0A1A-200 .
Refer to the wiring diagram for DTC P0AA6-526 .
Refer to the wiring diagram for DTC P324E-788 .
Refer to the wiring diagram for DTC U0110-159 .

INSPECTION PROCEDURE

CAUTION:
  1. Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
  2. After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (Click here).

    HINT:
    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

NOTICE:
  1. After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (Click here).
  2. After troubleshooting and repairing all output DTCs, be sure to replace the inverter with converter assembly. (Because the inverter with converter assembly may have broken or damage due to circuit malfunction.)

HINT:
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
  1. Turn the ignition switch to ON (READY) and wait for 5 seconds or more.
  2. Drive the vehicle for approximately 10 minutes mainly using the engine.

1.CHECK DTC OUTPUT (HYBRID CONTROL)
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

  1. Check if DTCs are output.

    Result:
    Result
    Proceed to
    P0A7A-203 is not output.
    A
    P0A7A-203 is also output.
    B

    NOTICE:
    1. If P0A7A-203 is output, troubleshoot it first. After completing the troubleshooting for P0A7A-203, return to perform troubleshooting for this DTC.
    2. Parts repaired or replaced during troubleshooting for P0A7A-203 do not need to be re-inspected in this diagnosis procedure.

  1. Turn the ignition switch off.



B
GO TO DTC CHART (P0A7A-203) (Click here)
A


2.CHECK DTC OUTPUT (HYBRID CONTROL)
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

  1. Check if DTCs are output.

    HINT:
    1. If P0A7A-203 was not output in step 1 of this diagnosis procedure, check Table 1 below.
    2. If P0A7A-203 was output in step 1 of this diagnosis procedure, repair that DTC first, then check Table 2 below.

    Result:
    Result
    Proceed to
    Only P0A7A-324 is output or DTCs other than the ones in the table below are also output.
    A
    Any of the following DTCs are also output.
    B


    Table 1 
    DTC No.
    Relevant Diagnosis
    P0A1A (all INF codes)*1
    Generator Control Module
    P0A1B (all INF codes)*1
    Drive Motor "A" Control Module
    P0A1D (all INF codes)*1
    Hybrid Powertrain Control Module
    P0A3F-243
    Drive Motor "A" Position Sensor Circuit
    P0A40-500
    Drive Motor "A" Position Sensor Circuit Range/Performance
    P0A41-245
    Drive Motor "A" Position Sensor Circuit Low
    P0A4B-253
    Generator Position Sensor Circuit
    P0A4C-513
    Generator Position Sensor Circuit Range/Performance
    P0A4D-255
    Generator Position Sensor Circuit Low
    P0A60 (all INF codes)*1
    Drive Motor "A" Phase V Current
    P0A63 (all INF codes)*1
    Drive Motor "A" Phase W Current
    P0A72 (all INF codes)*1
    Generator Phase V Current
    P0A75 (all INF codes)*1
    Generator Phase W Current
    P0A78-113, 128, 266, 267, 279, 284, 287, 306, 503, 504, 505, 506, 586, 806, 807, 808
    Drive Motor "A" Inverter Performance
    P0A7A-122, 130, 322, 325, 344, 517, 518, 809, 810, 811
    Generator Inverter Performance
    P0A90-509
    Drive Motor "A" Performance
    P0A92-521
    Hybrid Generator Performance
    P0A94-442, 547, 548, 549, 554, 555, 556, 585, 587, 589, 590
    DC/DC Converter Performance
    P0C73-776
    Motor Electronics Coolant Pump "A" Control Performance
    P0C76-523
    Hybrid Battery System Discharge Time Too Long
    P314A-828
    Inverter Coolant Pump Speed Signal

    Table 2 
    DTC No.
    Relevant Diagnosis
    P0A1A (all INF codes)*1
    Generator Control Module
    P0A1B (all INF codes)*1
    Drive Motor "A" Control Module
    P0A1D (all INF codes)*1
    Hybrid Powertrain Control Module
    P0A3F-243
    Drive Motor "A" Position Sensor Circuit
    P0A40-500
    Drive Motor "A" Position Sensor Circuit Range/Performance
    P0A41-245
    Drive Motor "A" Position Sensor Circuit Low
    P0A4B-253
    Generator Position Sensor Circuit
    P0A4C-513
    Generator Position Sensor Circuit Range/Performance
    P0A4D-255
    Generator Position Sensor Circuit Low
    P0A60 (all INF codes)*1
    Drive Motor "A" Phase V Current
    P0A63 (all INF codes)*1
    Drive Motor "A" Phase W Current
    P0A72-333
    Generator Phase V Current
    P0A75-341
    Generator Phase W Current
    P0A78-113, 128, 266, 267, 279, 284, 287, 306, 503, 504, 505, 506, 586, 806, 807, 808
    Drive Motor "A" Inverter Performance
    P0A7A-122, 130, 322, 325, 517, 518, 809, 810, 811
    Generator Inverter Performance
    P0A90-509
    Drive Motor "A" Performance
    P0A94-442, 547, 548, 549, 554, 555, 556, 585, 587, 589, 590
    DC/DC Converter Performance
    P0C73-776
    Motor Electronics Coolant Pump "A" Control Performance
    P0C76-523
    Hybrid Battery System Discharge Time Too Long
    P314A-828
    Inverter Coolant Pump Speed Signal

    HINT:
    1. *1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.
    2. P0A7A-324 may be set due to a malfunction which also causes DTCs in the preceding table to be set. In this case, first troubleshoot the output DTCs in the preceding table. After troubleshooting and repairing all output DTCs, be sure to replace the inverter with converter assembly.

  1. Turn the ignition switch off.



B
GO TO DTC CHART (HYBRID CONTROL SYSTEM) (Click here)
A


3.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.



    A267460
  1. Check the connector connections and contact pressure of the low voltage connectors of the inverter with converter assembly (Click here).

    NOTICE:
    Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector does not pull out.

    OK:
    The connectors are connected securely and there are no contact pressure problems.

    HINT:
    When connecting the connector, insert it with the locking lever in the raised position. Rotate the lever downward and make sure that the connector is pulled into its socket. When the locking lever is in its fully closed position, a click will be heard as its locking claws engage. After the click is heard, pull up on the connector to confirm that it is properly connected.



NG
CONNECT SECURELY
OK


4.CHECK QUANTITY OF HV COOLANT
  1. Check the HV coolant level in the inverter reserve tank.

  1. Check for HV coolant leaks.
    Result 
    Result
    Proceed to
    No leaks are found and coolant level in the inverter reserve tank assembly is above the low line.
    A
    No leaks are found and coolant level in the inverter reserve tank assembly is below the low line.
    B
    HV coolant leaks are evident.
    C

    HINT:
    1. After repairing the HV coolant leaks and adding coolant, perform the "Activate the Water Pump" Active Test (HV Active Test item) and the "Control the Electric Cooling Fan" Active Test (Engine Active Test item) and make sure that there are no malfunctions.
    2. The inverter water pump assembly will not malfunction due to coolant leaks.



B
ADD HV COOLANT

C
INSPECT FOR HV COOLANT LEAK AND ADD COOLANT
A


5.CHECK COOLANT HOSE
  1. Check if the hoses of the cooling system are kinked or clogged.



NG
CORRECT THE PROBLEM
OK


6.PERFORM ACTIVE TEST USING TECHSTREAM (CONTROL THE ELECTRIC COOLING FAN)
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON (IG).

  1. Clear DTCs (Click here).

  1. Enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Electric Cooling Fan.

  1. Perform the "Control the Electric Cooling Fan" Active Test.

    OK:
    The cooling fan rotates.

  1. Turn the ignition switch off.



NG
CHECK COOLING FAN SYSTEM (Click here)
OK


7.CHECK HV COOLANT (CHECK FOR CONDITIONS THAT MAY HAVE CAUSED FREEZING)
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

  1. Read the freeze frame data Ambient Temperature using the Techstream.

  1. Check if the freeze frame data Ambient Temperature is below freezing.

    Result:
    Result
    Proceed to
    Ambient Temperature value is above freezing temperature of the HV coolant.
    A
    Ambient Temperature value is below freezing temperature of the HV coolant.
    B

    HINT:
    1. HV coolant (SLLC) with a 30% concentration freezes at -15 °C (5°F) and HV coolant (SLLC) with a 50% concentration freezes at -35°C (-31°F).
    2. If the HV coolant freezes in the HV radiator or HV water pump, the coolant temperature in the inverter with converter assembly rises because the HV coolant cannot circulate. As a result, a DTC may be set.
    3. A DTC is set when the water pump impeller cannot rotate due to freezing of the HV coolant.
    4. If a DTC is set due to freezing of HV coolant, the problem cannot be reproduced. Judge whether freezing of HV coolant occurred according to the freeze point of the HV coolant, HV coolant change history and ambient temperature when the DTC was set.

  1. Turn the ignition switch off.



B
Go to step 33
A


8.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Disconnect connector C28 from the inverter with converter assembly.

  1. Connect the cable to the negative (-) auxiliary battery terminal.

  1. Turn the ignition switch to ON (IG).



    A217747E15
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    C28-11 (GRF) - Body ground
    Ignition switch ON (IG)
    Below 1 V
    C28-12 (GRFG) - Body ground
    Ignition switch ON (IG)
    Below 1 V
    C28-7 (GSN) - Body ground
    Ignition switch ON (IG)
    Below 1 V
    C28-8 (GSNG) - Body ground
    Ignition switch ON (IG)
    Below 1 V
    C28-10 (GCS) - Body ground
    Ignition switch ON (IG)
    Below 1 V
    C28-9 (GCSG) - Body ground
    Ignition switch ON (IG)
    Below 1 V

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Inverter with Converter Assembly)

    NOTICE:
    Turning the ignition switch to ON (IG) with the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

  1. Turn the ignition switch off.

  1. Disconnect the cable from the negative (-) auxiliary battery terminal.

  1. Connect the inverter with converter assembly connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


9.CHECK GENERATOR RESOLVER

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Disconnect connector C28 from the inverter with converter assembly.



    A217747E15
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Switch Condition
    Specified Condition
    C28-11 (GRF) - C28-12 (GRFG)
    Ignition switch off
    7.1 to 21.6 Ω
    C28-7 (GSN) - C28-8 (GSNG)
    Ignition switch off
    13.7 to 34.5 Ω
    C28-10 (GCS) - C28-9 (GCSG)
    Ignition switch off
    12.8 to 32.4 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Switch Condition
    Specified Condition
    C28-11 (GRF) or C28-12 (GRFG) - Body ground and other terminals
    Ignition switch off
    1 MΩ or higher
    C28-7 (GSN) or C28-8 (GSNG) - Body ground and other terminals
    Ignition switch off
    1 MΩ or higher
    C28-10 (GCS) or C28-9 (GCSG) - Body ground and other terminals
    Ignition switch off
    1 MΩ or higher

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Inverter with Converter Assembly)

  1. Connect the inverter with converter assembly connector.



NG
Go to step 22
OK


10.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Disconnect connector C28 from the inverter with converter assembly.

  1. Connect the cable to the negative (-) auxiliary battery terminal.

  1. Turn the ignition switch to ON (IG).



    A217747E16
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    C28-1 (MRF) - Body ground
    Ignition switch ON (IG)
    Below 1 V
    C28-2 (MRFG) - Body ground
    Ignition switch ON (IG)
    Below 1 V
    C28-3 (MSN) - Body ground
    Ignition switch ON (IG)
    Below 1 V
    C28-4 (MSNG) - Body ground
    Ignition switch ON (IG)
    Below 1 V
    C28-6 (MCS) - Body ground
    Ignition switch ON (IG)
    Below 1 V
    C28-5 (MCSG) - Body ground
    Ignition switch ON (IG)
    Below 1 V

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Inverter with Converter Assembly)

    NOTICE:
    Turning the ignition switch to ON (IG) with the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

  1. Turn the ignition switch off.

  1. Disconnect the cable from the negative (-) auxiliary battery terminal.

  1. Connect the inverter with converter assembly connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


11.CHECK MOTOR RESOLVER

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Disconnect connector C28 from the inverter with converter assembly.



    A217747E16
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Switch Condition
    Specified Condition
    C28-1 (MRF) - C28-2 (MRFG)
    Ignition switch off
    7.1 to 21.6 Ω
    C28-3 (MSN) - C28-4 (MSNG)
    Ignition switch off
    13.7 to 34.5 Ω
    C28-6 (MCS) - C28-5 (MCSG)
    Ignition switch off
    12.8 to 32.4 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Switch Condition
    Specified Condition
    C28-1 (MRF) or C28-2 (MRFG) - Body ground and other terminals
    Ignition switch off
    1 MΩ or higher
    C28-3 (MSN) or C28-4 (MSNG) - Body ground and other terminals
    Ignition switch off
    1 MΩ or higher
    C28-6 (MCS) or C28-5 (MCSG) - Body ground and other terminals
    Ignition switch off
    1 MΩ or higher

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Inverter with Converter Assembly)

  1. Connect the inverter with converter assembly connector.



NG
Go to step 24
OK


12.CHECK INVERTER WITH CONVERTER ASSEMBLY (MOTOR CABLE (FOR MG1) CONNECTION CONDITION)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.



    A258644
  1. Remove the inverter terminal cover from the inverter with converter assembly.



    A258645
  1. Remove the inverter cover from the inverter with converter assembly.



    A258647E01
  1. Check that the bolts for the motor cable (for MG1) are tightened to the specified torque, the motor cable (for MG1) is connected securely, and there are no contact problems.

    Specified Condition:
    Bolt A:
    T=8.0 N*m (82 kgf*cm, 71 in.*lbf)
    Bolt B:
    T=9.2 N*m (94 kgf*cm, 81 ft.*lbf)

    NOTICE:
    Make sure that the tightening torque of the bolt B is between 6.4 and 12 N*m (65 and 122 kgf*cm, 57 and 106 in.*lbf).

  1. Disconnect the motor cable (for MG1) from the inverter with converter assembly.

  1. Check for arc marks at the terminals for the motor cable (for MG1).

    Result:
    Result
    Proceed to
    The terminals are connected securely and there are no contact problems.
    There are no arc marks.
    A
    The terminals are not connected securely and there is a contact problem.
    There are arc marks.
    B
    The terminals are not connected securely and there is a contact problem.
    There are no arc marks.
    C
    The terminals are connected securely and there are no contact problems.
    There are arc marks.
    B

  1. Connect the motor cable (for MG1) to the inverter with converter assembly.

  1. Install the inverter cover.

  1. Install the inverter terminal cover.



B
REPLACE MALFUNCTIONING PARTS

C
CONNECT SECURELY
A


13.CHECK INVERTER WITH CONVERTER ASSEMBLY (MOTOR CABLE (FOR MG2) CONNECTION CONDITION)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.



    A258644
  1. Remove the inverter terminal cover from the inverter with converter assembly.



    A258646E01
  1. Check that the bolts for the motor cable (for MG2) are tightened to the specified torque, the motor cable (for MG2) is connected securely, and there are no contact problems.

    Specified Condition:
    Bolt A:
    T=8.0 N*m (82 kgf*cm, 71 in.*lbf)
    Bolt B:
    T=9.2 N*m (94 kgf*cm, 81 ft.*lbf)

    NOTICE:
    Make sure that the tightening torque of the bolt B is between 6.4 and 12 N*m (65 and 122 kgf*cm, 57 and 106 in.*lbf).

  1. Disconnect the motor cable (for MG2) from the inverter with converter assembly.

  1. Check for arc marks at the terminals for the motor cable (for MG2).

    Result:
    Result
    Proceed to
    The terminals are connected securely and there are no contact problems.
    There are no arc marks.
    A
    The terminals are not connected securely and there is a contact problem.
    There are arc marks.
    B
    The terminals are not connected securely and there is a contact problem.
    There are no arc marks.
    C
    The terminals are connected securely and there are no contact problems.
    There are arc marks.
    B

  1. Connect the motor cable (for MG2) to the inverter with converter assembly.

  1. Install the inverter terminal cover.



B
REPLACE MALFUNCTIONING PARTS

C
CONNECT SECURELY
A


14.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG1)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.



    A258644
  1. Remove the inverter terminal cover from the inverter with converter assembly.



    A258645
  1. Remove the inverter cover from the inverter with converter assembly.



    A258648
  1. Disconnect the motor cable from the inverter with converter assembly.



    A268150E04
  1. Check MG1 for an interphase short using a milliohmmeter.

    1. Using a milliohmmeter, measure the resistance according to the value(s) in the table below.

      HINT:
      If the MG1 temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.

      Standard Resistance:
      Tester Connection
      Switch Condition
      Specified Condition
      a2-1 (W) - a2-2 (U)
      Ignition switch off
      139.1 to 153.7 mΩ
      a2-2 (U) - a2-3 (V)
      Ignition switch off
      139.1 to 153.7 mΩ
      a2-3 (V) - a2-1 (W)
      Ignition switch off
      139.1 to 153.7 mΩ

      Text in Illustration 
      *1
      Shield Ground
      *a
      Motor Cable (for MG1)
      (Inverter with Converter Assembly Side)

      HINT:
      To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68° F).
      1. R20 = Rt / {1 + 0.00393 X (T - 20)}
      The calculation is based on the following:
      1. R20: Resistance at 20°C (68° F) (mΩ)
      2. Rt: Measured resistance (mΩ)
      3. T: Temperature when the resistance is measured (°C)

  1. Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

    NOTICE:
    Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    a2-1 (W) - Body ground and shield ground
    Ignition switch off
    100 MΩ or higher
    a2-2 (U) - Body ground and shield ground
    Ignition switch off
    100 MΩ or higher
    a2-3 (V) - Body ground and shield ground
    Ignition switch off
    100 MΩ or higher

  1. Connect the motor cable.

  1. Install the inverter cover.

  1. Install the inverter terminal cover.



NG
Go to step 29
OK


15.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG2)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.



    A258644
  1. Remove the inverter terminal cover from the inverter with converter assembly.



    A258645
  1. Remove the inverter cover from the inverter with converter assembly.



    A258648
  1. Disconnect the motor cable from the inverter with converter assembly.



    A268151E05
  1. Check MG2 for an interphase short using a milliohmmeter.

    1. Using a milliohmmeter, measure the resistance according to the value(s) in the table below.

      HINT:
      If the MG2 temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.

      Standard Resistance:
      Tester Connection
      Switch Condition
      Specified Condition
      a4-1 (W) - a4-2 (U)
      Ignition switch off
      172.5 to 190.7 mΩ
      a4-2 (U) - a4-3 (V)
      Ignition switch off
      172.5 to 190.7 mΩ
      a4-3 (V) - a4-1 (W)
      Ignition switch off
      172.5 to 190.7 mΩ

      Text in Illustration 
      *1
      Shield Ground
      *a
      Motor Cable (for MG2)
      (Inverter with Converter Assembly Side)

      HINT:
      To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68° F).
      1. R20 = Rt / {1 + 0.00393 X (T - 20)}
      The calculation is based on the following:
      1. R20: Resistance at 20°C (68° F) (mΩ)
      2. Rt: Measured resistance (mΩ)
      3. T: Temperature when the resistance is measured (°C)

  1. Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

    NOTICE:
    Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    a4-1 (W) - Body ground and shield ground
    Ignition switch off
    100 MΩ or higher
    a4-2 (U) - Body ground and shield ground
    Ignition switch off
    100 MΩ or higher
    a4-3 (V) - Body ground and shield ground
    Ignition switch off
    100 MΩ or higher

  1. Connect the motor cable.

  1. Install the inverter cover.

  1. Install the inverter terminal cover.



NG
Go to step 31
OK


16.CHECK FUSE (PCU)


    A263604E01
  1. Remove the PCU fuse from the No. 2 engine room relay block and No. 2 junction block assembly.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    PCU fuse terminal
    Always
    Below 1Ω

    Text in Illustration 
    *1
    No. 2 Engine Room Relay Block and No. 2 Junction Block Assembly
    *2
    PCU fuse

  1. Install the PCU fuse.



NG
Go to step 26
OK


17.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY POWER SOURCE CIRCUIT)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Disconnect connector A47 from inverter with converter assembly.



    A215725E63
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    A47-28 (GND1) - Body ground
    Ignition switch off
    Below 1 Ω
    A47-27 (GND2) - Body ground
    Ignition switch off
    Below 1 Ω

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Inverter with Converter Assembly)

  1. Connect the cable to the negative (-) auxiliary battery terminal.

  1. Turn the ignition switch to ON (IG).

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    A47-10 (+B) - Body ground
    Ignition switch On (IG)
    Same as auxiliary battery voltage
    A47-9 (+B2) - Body ground
    Ignition switch On (IG)
    Same as auxiliary battery voltage

    NOTICE:
    Turning the ignition switch to ON (IG) with the inverter with converter assembly connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

  1. Turn the ignition switch off.

  1. Disconnect the cable from the negative (-) auxiliary battery terminal.

  1. Connect the inverter with converter assembly connector.



NG
REPAIR OR REPLACE POWER SOURCE CIRCUIT
OK


18.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - POWER MANAGEMENT CONTROL ECU)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Disconnect connector A47 from the inverter with converter assembly.

  1. Disconnect connector A39 from the power management control ECU.



    A216755E16
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Switch Condition
    Specified Condition
    A47-8 (HTM+) - A39-24 (HTM+)
    Ignition switch off
    Below 1 Ω
    A47-18 (HTM-) - A39-25 (HTM-)
    Ignition switch off
    Below 1 Ω
    A47-7 (MTH+) - A39-30 (MTH+)
    Ignition switch off
    Below 1 Ω
    A47-17 (MTH-) - A39-29 (MTH-)
    Ignition switch off
    Below 1 Ω
    A47-6 (REQ+) - A39-33 (REQ+)
    Ignition switch off
    Below 1 Ω
    A47-16 (REQ-) - A39-32 (REQ-)
    Ignition switch off
    Below 1 Ω
    A47-5 (CLK+) - A39-21 (CLK+)
    Ignition switch off
    Below 1 Ω
    A47-15 (CLK-) - A39-20 (CLK-)
    Ignition switch off
    Below 1 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Switch Condition
    Specified Condition
    A47-8 (HTM+) or A39-24 (HTM+) - Body ground and other terminals
    Ignition switch off
    10 kΩ or higher
    A47-18 (HTM-) or A39-25 (HTM-) - Body ground and other terminals
    Ignition switch off
    10 kΩ or higher
    A47-7 (MTH+) or A39-30 (MTH+) - Body ground and other terminals
    Ignition switch off
    10 kΩ or higher
    A47-17 (MTH-) or A39-29 (MTH-) - Body ground and other terminals
    Ignition switch off
    10 kΩ or higher
    A47-6 (REQ+) or A39-33 (REQ+) - Body ground and other terminals
    Ignition switch off
    10 kΩ or higher
    A47-16 (REQ-) or A39-32 (REQ-) - Body ground and other terminals
    Ignition switch off
    10 kΩ or higher
    A47-5 (CLK+) or A39-21 (CLK+) - Body ground and other terminals
    Ignition switch off
    10 kΩ or higher
    A47-15 (CLK-) or A39-20 (CLK-) - Body ground and other terminals
    Ignition switch off
    10 kΩ or higher

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Inverter with Converter Assembly)
    *b
    Rear view of wire harness connector
    (to Power Management Control ECU)

  1. Connect the cable to the negative (-) auxiliary battery terminal.

  1. Turn the ignition switch to ON (IG).

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    A47-8 (HTM+) or A39-24 (HTM+) - Body ground
    Ignition switch ON (IG)
    Below 1 V
    A47-18 (HTM-) or A39-25 (HTM-) - Body ground
    Ignition switch ON (IG)
    Below 1 V
    A47-7 (MTH+) or A39-30 (MTH+) - Body ground
    Ignition switch ON (IG)
    Below 1 V
    A47-17 (MTH-) or A39-29 (MTH-) - Body ground
    Ignition switch ON (IG)
    Below 1 V
    A47-6 (REQ+) or A39-33 (REQ+) - Body ground
    Ignition switch ON (IG)
    Below 1 V
    A47-16 (REQ-) or A39-32 (REQ-) - Body ground
    Ignition switch ON (IG)
    Below 1 V
    A47-5 (CLK+) or A39-21 (CLK+) - Body ground
    Ignition switch ON (IG)
    Below 1 V
    A47-15 (CLK-) or A39-20 (CLK-) - Body ground
    Ignition switch ON (IG)
    Below 1 V

    NOTICE:
    Turning the ignition switch to ON (IG) with the power management control ECU and inverter with converter assembly connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

  1. Turn the ignition switch off.

  1. Disconnect the cable from the negative (-) auxiliary battery terminal.

  1. Connect the power management control ECU connector.

  1. Connect the inverter with converter assembly connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


19.CHECK POWER MANAGEMENT CONTROL ECU
  1. Disconnect connector A39 from the power management control ECU.



    A234460E10
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    A39-24 (HTM+) - A39-25 (HTM-)
    Ignition switch off
    80 to 170 Ω
    A39-30 (MTH+) - A39-29 (MTH-)
    Ignition switch off
    80 to 170 Ω
    A39-33 (REQ+) - A39-32 (REQ-)
    Ignition switch off
    80 to 170 Ω
    A39-21 (CLK+) - A39-20 (CLK-)
    Ignition switch off
    80 to 170 Ω

    Text in Illustration 
    *a
    Component without harness connected
    (Power Management Control ECU)

  1. Connect the power management control ECU connector.



NG
REPLACE POWER MANAGEMENT CONTROL ECU (Click here)
OK


20.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)


    A267571
  1. Check the connection of the generator resolver connector.

    OK:
    The connector is connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK


21.CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR)


    A267572
  1. Check the connection of the motor resolver connector.

    OK:
    The connector is connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK

REPLACE INVERTER WITH CONVERTER ASSEMBLY (Click here)  

22.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)


    A267571
  1. Check the connection of the generator resolver connector.

    OK:
    The connector is connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK


23.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Disconnect connector C28 from the inverter with converter assembly.



    A268860E02
  1. Disconnect the generator resolver connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Switch Condition
    Specified Condition
    C28-11 (GRF) - C24-1 (GRF)
    Ignition switch off
    Below 1 Ω
    C28-12 (GRFG) - C24-5 (GRFG)
    Ignition switch off
    Below 1 Ω
    C28-7 (GSN) - C24-2 (GSN)
    Ignition switch off
    Below 1 Ω
    C28-8 (GSNG) - C24-6 (GSNG)
    Ignition switch off
    Below 1 Ω
    C28-10 (GCS) - C24-3 (GCS)
    Ignition switch off
    Below 1 Ω
    C28-9 (GCSG) - C24-7 (GCSG)
    Ignition switch off
    Below 1 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Switch Condition
    Specified Condition
    C28-11 (GRF) or C24-1 (GRF) - Body ground and other terminals
    Ignition switch off
    1 MΩ or higher
    C28-12 (GRFG) or C24-5 (GRFG) - Body ground and other terminals
    Ignition switch off
    1 MΩ or higher
    C28-7 (GSN) or C24-2 (GSN) - Body ground and other terminals
    Ignition switch off
    1 MΩ or higher
    C28-8 (GSNG) or C24-6 (GSNG) - Body ground and other terminals
    Ignition switch off
    1 MΩ or higher
    C28-10 (GCS) or C24-3 (GCS) - Body ground and other terminals
    Ignition switch off
    1 MΩ or higher
    C28-9 (GCSG) or C24-7 (GCSG) - Body ground and other terminals
    Ignition switch off
    1 MΩ or higher

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Inverter with Converter Assembly)
    *b
    Front view of wire harness connector
    (to Generator Resolver)

    HINT:
    The generator resolver is not available separately. If it requires replacement, replace the hybrid vehicle transaxle assembly.

  1. Connect the generator resolver connector.

  1. Connect the inverter with converter assembly connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY (Click here)  

24.CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR)


    A267572
  1. Check the connection of the motor resolver connector.

    OK:
    The connector is connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK


25.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Disconnect connector C28 from the inverter with converter assembly.



    A268861E02
  1. Disconnect the motor resolver connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Switch Condition
    Specified Condition
    C28-1 (MRF) - C26-3 (MRF)
    Ignition switch off
    Below 1 Ω
    C28-2 (MRFG) - C26-6 (MRFG)
    Ignition switch off
    Below 1 Ω
    C28-3 (MSN) - C26-1 (MSN)
    Ignition switch off
    Below 1 Ω
    C28-4 (MSNG) - C26-4 (MSNG)
    Ignition switch off
    Below 1 Ω
    C28-6 (MCS) - C26-2 (MCS)
    Ignition switch off
    Below 1 Ω
    C28-5 (MCSG) - C26-5 (MCSG)
    Ignition switch off
    Below 1 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Switch Condition
    Specified Condition
    C28-1 (MRF) or C26-3 (MRF) - Body ground and other terminals
    Ignition switch off
    1 MΩ or higher
    C28-2 (MRFG) or C26-6 (MRFG) - Body ground and other terminals
    Ignition switch off
    1 MΩ or higher
    C28-3 (MSN) or C26-1 (MSN) - Body ground and other terminals
    Ignition switch off
    1 MΩ or higher
    C28-4 (MSNG) or C26-4 (MSNG) - Body ground and other terminals
    Ignition switch off
    1 MΩ or higher
    C28-6 (MCS) or C26-2 (MCS) - Body ground and other terminals
    Ignition switch off
    1 MΩ or higher
    C28-5 (MCSG) or C26-5 (MCSG) - Body ground and other terminals
    Ignition switch off
    1 MΩ or higher

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Inverter with Converter Assembly)
    *b
    Front view of wire harness connector
    (to Motor Resolver)

    HINT:
    The motor resolver is not available separately. If it requires replacement, replace the hybrid vehicle transaxle assembly.

  1. Connect the motor resolver connector.

  1. Connect the inverter with converter assembly connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY (Click here)  

26.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - PCU FUSE)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Disconnect connector A47 from the inverter with converter assembly.



    A215725E64
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    A47-10 (+B) - Body ground
    Ignition switch off
    10 kΩ or higher
    A47-9 (+B2) - Body ground
    Ignition switch off
    10 kΩ or higher

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Inverter with Converter Assembly)

  1. Connect the inverter with converter assembly connector.



NG
Go to step 28
OK


27.REPLACE INVERTER WITH CONVERTER ASSEMBLY
(Click here)

NEXT

REPLACE FUSE (PCU) 

28.REPAIR OR REPLACE HARNESS OR CONNECTOR

NEXT

REPLACE FUSE (PCU) 

29.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MOTOR CABLE (FOR MG1) CONNECTION CONDITION)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the inverter with converter assembly (Click here).



    A258652E01
  1. Check that the bolts for the motor cable (for MG1) are tightened to the specified torque, the motor cable (for MG1) is connected securely, and there are no contact problems.

    Specified Condition:
    Bolt A:
    T=19.5 N*m (199 kgf*cm, 14 ft.*lbf)
    Bolt B:
    T=10 N*m (102 kgf*cm, 7 ft.*lbf)

    NOTICE:
    1. Make sure that the tightening torque of the bolt A is between 13.5 and 25 N*m (138 and 255 kgf*cm, 10 and 18 ft.*lbf).
    2. Make sure that the tightening torque of the bolt B is between 8 and 12 N*m (82 and 122 kgf*cm, 71 and 106 in.*lbf).

  1. Disconnect the motor cable (for MG1) from the hybrid vehicle transaxle assembly.

  1. Check for arc marks at the terminals for the motor cable (for MG1).

    Result:
    Result
    Proceed to
    The terminals are connected securely and there are no contact problems.
    There are no arc marks.
    A
    The terminals are not connected securely and there is a contact problem.
    There are arc marks.
    B
    The terminals are not connected securely and there is a contact problem.
    There are no arc marks.
    C
    The terminals are connected securely and there are no contact problems.
    There are arc marks.
    B

  1. Connect the motor cable (for MG1) to the hybrid vehicle transaxle assembly.

  1. Install the inverter with converter assembly.



B
REPLACE MALFUNCTIONING PARTS

C
CONNECT SECURELY
A


30.CHECK MOTOR CABLE (FOR MG1)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the motor cable (Click here).



    A258650E02
  1. Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

    NOTICE:
    Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    a2-1 (W) - Body ground and shield ground
    Ignition switch off
    100 MΩ or higher
    a2-2 (U) - Body ground and shield ground
    Ignition switch off
    100 MΩ or higher
    a2-3 (V) - Body ground and shield ground
    Ignition switch off
    100 MΩ or higher

    Text in Illustration 
    *1
    Shield ground
    *a
    Motor Cable (for MG1)
    (Inverter with Converter Assembly Side)
    *b
    Motor Cable (for MG1)
    (Hybrid Vehicle Transaxle Assembly Side)

    NOTICE:
    Wrap the terminal of the motor cable (for MG1) with insulating tape to prevent them from coming into contact with body ground

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    a2-1 (W) - a1-1 (W)
    Ignition switch off
    Below 1 Ω
    a2-2 (U) - a1-2 (U)
    Ignition switch off
    Below 1 Ω
    a2-3 (V) - a1-3 (V)
    Ignition switch off
    Below 1 Ω
    a2-1 (W) - a1-2 (U)
    Ignition switch off
    100 MΩ or higher
    a2-2 (U) - a1-3 (V)
    Ignition switch off
    100 MΩ or higher
    a2-3 (V) - a1-1 (W)
    Ignition switch off
    100 MΩ or higher

  1. Install the motor cable.



NG
REPLACE MOTOR CABLE (Click here)
OK

REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY (Click here)  

31.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MOTOR CABLE (FOR MG2) CONNECTION CONDITION)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.



    A258653E01
  1. Check that the bolts for the motor cable (for MG2) are tightened to the specified torque, the motor cable (for MG2) is connected securely, and there are no contact problems.

    Specified Condition:
    Bolt A:
    T=19.5 N*m (199 kgf*cm, 14 ft.*lbf)
    Bolt B:
    T=10 N*m (102 kgf*cm, 7 ft.*lbf)

    NOTICE:
    1. Make sure that the tightening torque of the bolt A is between 13.5 and 25 N*m (138 and 255 kgf*cm, 10 and 18 ft.*lbf).
    2. Make sure that the tightening torque of the bolt B is between 8 and 12 N*m (82 and 122 kgf*cm, 71 and 106 in.*lbf).

  1. Disconnect the motor cable (for MG2) from the hybrid vehicle transaxle assembly.

  1. Check for arc marks at the terminals for the motor cable (for MG2).

    Result:
    Result
    Proceed to
    The terminals are connected securely and there are no contact problems.
    There are no arc marks.
    A
    The terminals are not connected securely and there is a contact problem.
    There are arc marks.
    B
    The terminals are not connected securely and there is a contact problem.
    There are no arc marks.
    C
    The terminals are connected securely and there are no contact problems.
    There are arc marks.
    B

  1. Connect the motor cable (for MG2) to the hybrid vehicle transaxle assembly.



B
REPLACE MALFUNCTIONING PARTS

C
CONNECT SECURELY
A


32.CHECK MOTOR CABLE (FOR MG2)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the motor cable (Click here).



    A258651E01
  1. Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

    NOTICE:
    Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    a4-1 (W) - Body ground and shield ground
    Ignition switch off
    100 MΩ or higher
    a4-2 (U) - Body ground and shield ground
    Ignition switch off
    100 MΩ or higher
    a4-3 (V) - Body ground and shield ground
    Ignition switch off
    100 MΩ or higher

    Text in Illustration 
    *1
    Shield ground
    *a
    Motor Cable (for MG2)
    (Inverter with Converter Assembly Side)
    *b
    Motor Cable (for MG2)
    (Hybrid Vehicle Transaxle Assembly Side)

    NOTICE:
    Wrap the terminal of the motor cable (for MG2) with insulating tape to prevent them from coming into contact with body ground

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    a4-1 (W) - a3-1 (W)
    Ignition switch off
    Below 1 Ω
    a4-2 (U) - a3-3 (U)
    Ignition switch off
    Below 1 Ω
    a4-3 (V) - a3-2 (V)
    Ignition switch off
    Below 1 Ω
    a4-1 (W) - a3-3 (U)
    Ignition switch off
    100 MΩ or higher
    a4-2 (U) - a3-2 (V)
    Ignition switch off
    100 MΩ or higher
    a4-3 (V) - a3-1 (W)
    Ignition switch off
    100 MΩ or higher

  1. Install the motor cable.



NG
REPLACE MOTOR CABLE (Click here)
OK

REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY (Click here)  

33.REPLACE HV COOLANT
  1. Replace the HV coolant with coolant having an appropriate concentration (appropriate freeze point) for the vehicle usage conditions (Click here).


NEXT

COMPLETED