Home › Vehicle Interior › LIGHTING (INT) › LIGHTING SYSTEM

LIGHTING SYSTEM > ACC Signal Circuit

for Preparation Click here


DESCRIPTION

This circuit detects the ignition switch ACC or off condition, and sends it to the main body ECU (multiplex network body ECU).

WIRING DIAGRAM


E227110E01


INSPECTION PROCEDURE

NOTICE:
Inspect the fuses for circuits related to this system before performing the following inspection procedure.

1.CHECK VEHICLE CONDITION
  1. Check the vehicle condition.

    Result 
    Result
    Proceed to
    w/ Smart Key System
    A
    w/o Smart Key System
    B



B
Go to step 6
A


2.CHECK DTC (SMART KEY SYSTEM (for Start Function))
  1. Check for DTCs (Click here).

    Result 
    Result
    Proceed to
    DTC is not output
    A
    DTC is output
    B



B
GO TO SMART KEY SYSTEM (for Start Function) (Click here)
A


3.READ VALUE USING TECHSTREAM
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON (IG).

  1. Turn the Techstream on.

  1. Enter the following menus: Body Electrical / Main Body / Data List.

  1. Read the display on the Techstream.

    Main Body 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    ACC SW
    Ignition switch ACC signal/ON or OFF
    ON: Ignition switch ACC
    OFF: Ignition switch off
    -

    OK:
    Normal conditions listed above are displayed.



NG
Go to step 4
OK

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)  

4.CHECK HARNESS AND CONNECTOR (DC/DC FUSE - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
  1. Disconnect the 3E instrument panel junction block assembly connectors.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    3E-1 - Body ground
    Ignition switch off
    11 to 14 V



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


5.INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
  1. Remove the instrument panel junction block assembly (Click here).

  1. Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.



  1. Measure the resistance according to the value(s) in the table below.


    E191508E05


    Text in Illustration 
    *a
    Component without harness connected
    (Instrument Panel Junction Block Assembly)
    -
    -

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    3E-1 - MB-29 (ACC)
    Always
    10 kΩ or higher
    3E-1 - MB-29 (ACC)
    Auxiliary battery positive (+) → 3B-37
    Auxiliary battery negative (-) → 3B-8
    Below 1 Ω



NG
REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY (Click here)
OK

REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU) (Click here)  

6.READ VALUE USING TECHSTREAM
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON (IG).

  1. Turn the Techstream on.

  1. Enter the following menus: Body Electrical / Main Body / Data List.

  1. Read the display on the Techstream.

    Main Body 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    ACC SW
    Ignition switch ACC signal/ON or OFF
    ON: Ignition switch ACC
    OFF: Ignition switch off
    -

    OK:
    Normal conditions listed above are displayed.



NG
Go to step 7
OK

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)  

7.CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY - DC/DC FUSE AND BODY GROUND)
  1. Disconnect the 3E and 3B instrument panel junction block assembly connectors.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    3E-1 - Body ground
    Ignition switch off
    11 to 14 V

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    3B-8 - Body ground
    Always
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


8.INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY


    E245104E02
  1. Reconnect the 3B and 3E instrument panel junction block assembly connectors.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    3B-37 - Body ground
    Ignition switch ACC
    11 to 14 V

    *a
    Component with harness connected
    (Instrument panel junction block assembly)



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


9.INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
  1. Remove the instrument panel junction block assembly (Click here).

  1. Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.



  1. Measure the resistance according to the value(s) in the table below.


    E191508E05


    Text in Illustration 
    *a
    Component without harness connected
    (Instrument Panel Junction Block Assembly)
    -
    -

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    3E-1 - MB-29 (ACC)
    Always
    10 kΩ or higher
    3E-1 - MB-29 (ACC)
    Auxiliary battery positive (+) → 3B-37
    Auxiliary battery negative (-) → 3B-8
    Below 1 Ω



NG
REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY (Click here)
OK

REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU) (Click here)