DTC P0A85-123 Hybrid Battery Pack Cooling Fan 1 Control Circuit High |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P0A85 | 123 | Both of the following conditions are met due to the battery cooling blower system malfunction: (1 trip detection logic)
|
|
| DTC No. | Data List |
| P0A85-123 |
|
| 1.CHECK FOR DTCS (HV) |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check and record any HV system DTCs, INF codes and freeze frame data.
Read output DTCs (Click here).
| Result | Proceed to |
| P0AFC-123 is not output. | A |
| P0AFC-123 is also output. | B |
Turn the ignition switch off.
Disconnect the Techstream from the DLC3.
|
| ||||
| A | |
| 2.CHECK BATTERY SMART UNIT (FREQUENCY) |
Check that the service plug grip is not installed.
Remove the rear seat cushion leg sub-assembly .
Connect the cable to the negative (-) auxiliary battery terminal.
Connect the Techstream to the DLC3.
Turn the ignition switch to ON (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Clear DTCs and freeze frame data.
Enter the following menus: Powertrain / Hybrid Control / Active Test / Driving the Battery Cooling Fan.
Enter the following menus: Powertrain / Hybrid Control / Data List / All Data / Cooling Fan Frequency 1.
Select each air volume mode (1 to 6) in the "Driving the Battery Cooling Fan" Active Test to operate the battery cooling blower assembly.
![]() |
While the cooling fan is operating, compare the value in the data list (Cooling Fan Frequency 1) with the Frequency value that was actually measured at the battery cooling blower assembly connector.
| Tester Connection | Condition |
| M41-2 (FP0) - M41-4 (GND0) | Battery cooling blower is operating |
| *a | Component with harness connected (Battery Cooling Blower Assembly) |
| *b | Rear view of wire harness connector (to Battery Cooling Blower Assembly) |
| Result | Proceed to |
| The value in the Data List (Cooling Fan Frequency 1) and the actual measurement value at the battery cooling blower assembly connector are 0 Hz. | A |
| The value in the Data List (Cooling Fan Frequency 1) and the actual measurement value at the battery cooling blower assembly connector are not 0 Hz. | B |
Turn the ignition switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Install the rear seat cushion leg sub-assembly.
|
| ||||
| A | |
| 3.CHECK BATTERY SMART UNIT |
Check that the service plug grip is not installed.
Remove the rear seat cushion leg sub-assembly .
Disconnect connector M39 from the battery smart unit.
Connect the cable to the negative (-) auxiliary battery terminal.
Connect the Techstream to the DLC3.
Turn the ignition switch to ON (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Clear DTCs and freeze frame data.
Enter the following menus: Powertrain / Hybrid Control / Active Test / Driving the Battery Cooling Fan.
Enter the following menus: Powertrain / Hybrid Control / Data List / All Data / Cooling Fan Frequency 1.
Select each air volume mode (1 to 6) in the "Driving the Battery Cooling Fan" Active Test to operate the battery cooling blower assembly.
![]() |
While the cooling fan is operating, measure the frequency on the wire harness side of the battery cooling blower assembly connector.
| Tester Connection | Condition |
| M39-5 (FP0) - Body ground | Battery cooling blower is operating |
| *a | Front view of wire harness connector (to Battery Smart Unit) |
| Result | Proceed to |
| The actual measured value at the battery cooling blower assembly connector remains 0 Hz. | A |
| The actual measured value at the battery cooling blower assembly connector is not 0 Hz. | B |
Turn the ignition switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Connect the battery cooling blower assembly connector.
Install the rear seat cushion leg sub-assembly.
|
| ||||
| A | ||
| ||
| 4.CHECK BATTERY SMART UNIT |
Check that the service plug grip is not installed.
Remove the rear seat cushion leg sub-assembly .
Connect the cable to the negative (-) auxiliary battery terminal.
Connect the Techstream to the DLC3.
Turn the ignition switch to ON (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Clear DTCs and freeze frame data.
Enter the following menus: Powertrain / Hybrid Control / Active Test / Driving the Battery Cooling Fan.
Enter the following menus: Powertrain / Hybrid Control / Data List / All Data / Cooling Fan Frequency 1.
Select each air volume mode (1 to 6) in the "Driving the Battery Cooling Fan" Active Test to operate the battery cooling blower assembly.
![]() |
While the cooling fan is operating, compare the value in the data list (Cooling Fan Frequency 1) with the Frequency value that was actually measured at the battery cooling blower assembly connector.
| Tester Connection | Condition |
| M41-2 (FP0) - M41-4 (GND0) | Battery cooling blower is operating |
| *a | Component with harness connected (Battery Cooling Blower Assembly) |
| *b | Rear view of wire harness connector (to Battery Cooling Blower Assembly) |
| Result | Proceed to |
| Difference between the value in the Data List (Cooling Fan Frequency 1) and the actual measurement value at the battery cooling blower assembly connector is 10% or less. | A |
| Difference between the value in the Data List (Cooling Fan Frequency 1) and the actual measurement value at the battery cooling blower assembly connector is more than 10%. | B |
Turn the ignition switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Install the rear seat cushion leg sub-assembly.
|
| ||||
| A | ||
| ||