DTC P0451 Evaporative Emission Control System Pressure Sensor Range / Performance |
DTC P0452 Evaporative Emission Control System Pressure Sensor / Switch Low Input |
DTC P0453 Evaporative Emission Control System Pressure Sensor / Switch High Input |
| DTC No. | Monitoring Item | Malfunction Detection Condition | Trouble Area | Detection Timing | Detection Logic |
| P0451 | Canister pressure sensor abnormal voltage fluctuation | Sensor output voltage fluctuates frequently in a certain time period. |
|
| 2 trip |
| P0452 | Canister pressure sensor low input | EVAP pressure sensor less than 42.11 kPa(abs) [315.867 mmHg(abs)] for 0.5 seconds. |
| 1 trip | |
| P0453 | Canister pressure sensor high input | EVAP pressure sensor higher than 123.761 kPa(abs) [928.331 mmHg(abs)] for 0.5 seconds. |
| 1 trip |

| Required Sensors/Components | Canister pump module |
| Frequency of Operation | Continuous |
| Duration | Within 15 seconds: P0451 0.5 seconds: P0452, P0453 |
| MIL Operation | Immediately: P0452, P0453 2 driving cycles: P0451 |
| Sequence of Operation | None |
| Monitor runs whenever following DTCs are not present | None |
| Atmospheric pressure | 70 kPa(abs) [525 mmHg(abs)] or more, and less than 111 kPa(abs) [833 mmHg(abs)] |
| Auxiliary battery voltage | 10.5 V or more |
| Intake air temperature | 4.4°C (40°F) or more, and less than 50°C (122°F) |
| Canister pressure sensor malfunction (P0452, P0453) | Not detected |
| Either of the following conditions 1 or 2 is met: | - |
| 1. Engine condition | Running |
| 2. Time after key-off | 5, 7 or 9.5 hours |
| All of the following conditions are met | - |
| Either of the following condition is met | Condition (a) or (b) |
| (a) Power switch | On (IG) |
| (b) Soak monitor | On |
| Auxiliary battery voltage | 8 V or higher |
| Starter | Off |
| Frequency that EVAP pressure change is 0.3 kPa(gauge) [2.25 mmHg(gauge)] or more | 10 times or more in 10 seconds |
| EVAP pressure | Less than 42.11 kPa(abs) [315.867 mmHg(abs)] |
| EVAP pressure | More than 123.761 kPa(abs) [928.331 mmHg(abs)] |
| Techstream Display | Description |
| NORMAL |
|
| ABNORMAL |
|
| INCOMPLETE |
|
| N/A |
|

| 1.CONFIRM DTC AND EVAP PRESSURE |
Connect the Techstream to the DLC3.
Turn the power switch on (IG) (do not start the engine).
Turn the Techstream on.
Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.
Read the DTCs.
Enter the following menus: Powertrain / Engine and ECT / Data List / Gas Evaporative / Vapor Pressure Pump.
Read the EVAP (Evaporative Emission) pressure displayed on the Techstream.
| Display (DTC Output) | Test Result | Suspected Trouble Area | Proceed to |
| P0451 | - | Canister pressure sensor | C |
| P0452 | Less than 42.11 kPa(abs) [315.867 mmHg(abs)] |
| A |
| P0453 | More than 123.761 kPa(abs) [928.331 mmHg(abs)] |
| B |
|
| ||||
|
| ||||
| A | |
| 2.CHECK HARNESS AND CONNECTOR (CANISTER PUMP MODULE - ECM) |
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition | Suspected Trouble Area | Proceed to |
| D28-114 (PPMP) - Body ground | Always | Below 10 Ω |
| A |
| 10 kΩ or higher |
| B |
|
| ||||
| A | |
| 3.CHECK HARNESS AND CONNECTOR (CANISTER PUMP MODULE - ECM) |
Disconnect the canister pump module connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition | Suspected Trouble Area | Proceed to |
| D28-114 (PPMP) - Body ground | Always | 10 kΩ or higher | Short in canister pressure sensor circuit | A |
| Below 10 Ω | Short in wire harness/connector (ECM - Canister pressure sensor) | B |
|
| ||||
|
| ||||
| 4.CHECK HARNESS AND CONNECTOR (CANISTER PUMP MODULE - ECM) |
Disconnect the canister pump module connector.

Turn the power switch on (IG).
Measure the voltage and resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| S16-6 (VCC) - Body ground | Power switch on (IG) | 4.5 to 5.5 V |
| S16-7 (VOUT) - Body ground | Power switch on (IG) | 4.5 to 5.5 V |
| Tester Connection | Condition | Specified Condition |
| S16-8 (SGND) - Body ground | Always | Below 100 Ω |
| *a | Front view of wire harness connector (to Canister Pump Module) | - | - |
| Test Result | Suspected Trouble Area | Proceed to |
| Voltage and resistance within standard ranges | Open in canister pressure sensor circuit | A |
| Voltage and resistance outside standard ranges | Open in wire harness/connector (ECM - canister pressure sensor) | B |
|
| ||||
| A | |
| 5.REPLACE CANISTER (CANISTER PUMP MODULE) |
Replace the canister (Click here).

| *1 | Fuel Tank Vent Hose | *2 | Air Inlet Port |
| *3 | Vent Hose | *4 | Fuel Tank |
| *5 | No. 2 Canister | *6 | No. 1 Canister |
| *7 | Canister | *8 | Canister Air Filter |
| *9 | Canister Pump Module | - | - |
| *a | Inspection Area (Check for Disconnection and/or cracks) | - | - |
|
| ||||
| 6.REPAIR OR REPLACE HARNESS OR CONNECTOR (CANISTER PUMP MODULE - ECM) |
|
| ||||
| 7.REPLACE ECM |
Replace the ECM (Click here).
| NEXT | |
| 8.CHECK WHETHER DTC OUTPUT RECURS (AFTER REPAIR) |
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Turn the Techstream on.
Clear the DTCs (Click here).
Turn the power switch off and wait for at least 30 seconds.
Turn the power switch on (IG).
Turn the Techstream on.
Perform the Evaporative System Check using the Techstream, referring to the Confirmation Driving Pattern.
Enter the following menus: Powertrain / Engine and ECT / Utility / All Readiness.
Input the DTC: P0451, P0452 or P0453.
Check the DTC judgment result.
| Techstream Display | Description |
| NORMAL |
|
| ABNORMAL |
|
| INCOMPLETE |
|
| N/A |
|
| NEXT | ||
| ||