Home › Vehicle Interior › THEFT DETERRENT / KEYLESS ENTRY › ENGINE IMMOBILISER SYSTEM

ENGINE IMMOBILISER SYSTEM > Security Indicator Light Does not Blink

for Preparation Click here


DESCRIPTION

The security indicator light blinks continuously due to a continuous signal received from the certification ECU (smart key ECU assembly) while the engine immobiliser is set.

WIRING DIAGRAM


B203494E07


INSPECTION PROCEDURE

NOTICE:
  1. If the certification ECU (smart key ECU assembly) is replaced, register all the keys and ECU communication ID (Click here).*1
  2. If the certification ECU (smart key ECU assembly) is replaced, register all the keys (Click here).*2
    1. *1: except Canada
    2. *2: for Canada

1.PERFORM ACTIVE TEST USING TECHSTREAM
  1. Connect the Techstream to the DLC3.

  1. Turn the power switch on (IG).

  1. Turn the Techstream on.

  1. Enter the following menus: Body Electrical / Smart Key / Active Test.

  1. Perform the Active Test according to the display on the Techstream.

    Smart Key (Certification ECU (Smart Key ECU Assembly)) 
    Tester Display
    Test Part
    Control Range
    Diagnostic Note
    Immobiliser Indicator
    Security indicator light
    ON or OFF
    -

    OK:
    The security indicator light turns on and off according to operation via the Techstream.



NG
Go to step 2
OK

REPLACE CERTIFICATION ECU (SMART KEY ECU ASSEMBLY) (Click here)  

2.INSPECT COMBINATION METER ASSEMBLY
  1. Disconnect the combination meter assembly connector.



    B229598E01
  1. Measure the voltage according to the value(s) in the table below.

    Standard:
    Tester Connection
    Condition
    Specified Condition
    L27-22 (LP) - Body ground
    1. Power switch on (IG)
    2. Security indicator light off
    Below 2 V
    L27-22 (LP) - Body ground
    1. Power switch off
    2. Security indicator light blinks
    Pulse generation

    Text in Illustration 
    *1
    Front view of wire harness connector
    (to Combination Meter Assembly)



NG
Go to step 4
OK


3.CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - BODY GROUND)


    B229598E02
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    L27-30 (ES) - Body ground
    Always
    Below 1 Ω

    Text in Illustration 
    *1
    Front view of wire harness connector
    (to Combination Meter Assembly)



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE NO. 3 METER CIRCUIT PLATE (Click here)  

4.CHECK HARNESS AND CONNECTOR (CERTIFICATION ECU - COMBINATION METER ASSEMBLY)


    B229597E01
  1. Disconnect the certification ECU (smart key ECU assembly) connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    L62-2 (IND) - L27-22 (LP)
    Always
    Below 1 Ω
    L62-2 (IND) - Body ground
    Always
    10 kΩ or higher
    L27-22 (LP) - Body ground
    Always
    10 kΩ or higher

    Text in Illustration 
    *1
    Front view of wire harness connector
    (to Certification ECU (Smart Key ECU Assembly))
    *2
    Front view of wire harness connector
    (to Combination Meter Assembly)



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE CERTIFICATION ECU (SMART KEY ECU ASSEMBLY) (Click here)